← Back
Two stories - detached, small or mid-size
731 EAST 226 STREET
BRONX · Williamsbridge-Olinville · BIN 2063466
💬 Discuss this project
1899Year Built
2Stories
A1Building Class
R5Zoning
2,092 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,850 sf lot · 0.73 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalGeneral
Roof2p · 1 filing · 13 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/30/2014$339K—Private party → Private party$162/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC203/31/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNCO CAPITAL LLCGeneral Contractor104/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854203/31/2025
Building Lifecycle
All (20)Filed (2)Permit Issued (1)Signed Off (1)Objection (6)Special Inspection (10)
10/07/2025
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01157411-I1
05/20/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
05/20/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
05/20/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
05/20/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/20/2025
Special inspection requirement — Final
TOM PETERSEN
03/31/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01157411-P1
03/31/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
03/31/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
03/31/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
03/31/2025
Special inspection requirement — Final
TOM PETERSEN
03/31/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
03/24/2025
Permit issued — Solar
X01157411-I1-SL
03/11/2025
Objection resolved — Addressed
03/11/2025
Objection resolved — Addressed
03/11/2025
Objection resolved — Addressed
01/17/2025
Objection raised — Other
01/17/2025
Objection raised — Other
01/17/2025
Objection raised — Other
01/07/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01157411-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNCO CAPITAL LLC03/24/2025
2 projects · most recent 01/09/2025
FiledStatusContractorScope
01/09/2025CompleteBERGER QUALITY ELEC'L CON—
01/02/2025Permit IssuedBERGER QUALITY ELEC'L CON1 meters
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
05/20/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
05/20/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
05/20/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
05/20/2025Energy Code Compliance InspectionsTOM PETERSENprogress
05/20/2025FinalTOM PETERSENprogress
03/31/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
03/31/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
03/31/2025Energy Code Compliance InspectionsTOM PETERSENprogress
03/31/2025FinalTOM PETERSENprogress
03/31/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 24 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/19/2026X01157411-I1Request digital key ↗
08/19/2026X01157411-P1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
09/20/2013220162641Open ↗
01/04/2012220162641Open ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature4
08/29/2026X01157411-I1Open ↗
08/29/2026X01157411-I1Open ↗
08/27/2026X01157411-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/19/2026X01157411-I1Open ↗
08/13/2026X01157411-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/29/2026X01157411-I1Open ↗
08/27/2026X01157411-P1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
01/04/2012220162641Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
01/04/2012220162641Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
01/04/2012220162641Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/19/2026X01157411-I1Open ↗
08/13/2026X01157411-P1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
01/04/2012220162641Open ↗
▸Approvals, Objections & Sign-offs3
▸BISSCHEDULE A - OCCUPANCY / USE1
01/04/2012220162641Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
01/04/2012220162641Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01157411-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
01/04/2012220162641Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
01/04/2012220162641Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
01/04/2012220162641Open ↗