← Back
Two family brick
736 LINCOLN PLACE
BROOKLYN · BIN 3032615
💬 Discuss this project
1901Year Built
2Stories
B1Building Class
R6BZoning
1,936 sfGross Floor Area
2Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Two family brick · 1,600 sf lot · 1.21 FAR built · Flood zone X
Locations of Work
Electrical
Floor 11p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BRICKSTONE GROUP604/09/2026
MORELL BUILDERS103/22/2026
360 CHAI LLC103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/20/2025$1.4M—— → —$723/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CQ&J CORPORATION606/03/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WM ARCH603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MORELL BUILDERS INCGeneral Contractor104/09/2026
PLBG P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SIMON7555506/03/2026
Building Lifecycle
All (47)Filed (6)Permit Issued (2)Signed Off (2)Violation (2)Inspection (5)Special Inspection (30)
06/18/2026
Signed off — Alteration
EXISTING 2-FAMILY HOUSE WITH INTERIOR RENOVATION ON PARTITION,MECHANICAL WORK AT THE BASEMENT, 1ST, 2ND FLOOR AND OPEN SPACEUNDER THIS APPLICATION. INSTALL A NEW BULKHEAD. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THISAPPLICATION.
B01289021-I1
06/15/2026
Signed off — Alteration
EXISTING 2-FAMILY HOUSE WITH INTERIOR RENOVATION ON PARTITION,MECHANICAL WORK AT THE BASEMENT, 1ST, 2ND FLOOR AND OPEN SPACEUNDER THIS APPLICATION. INSTALL A NEW BULKHEAD. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THISAPPLICATION.
B01289021-S1
06/05/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SIMON JIANG
06/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SIMON JIANG
06/05/2026
Special inspection requirement — Structural Wood Frame
CALVIN TRAN
06/05/2026
Special inspection requirement — Final
CALVIN TRAN
06/05/2026
Special inspection requirement — Fire-Resistance Rated Construction
CALVIN TRAN
06/05/2026
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
06/05/2026
Special inspection requirement — Metering
CALVIN TRAN
06/05/2026
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
06/05/2026
Special inspection requirement — Insulation placement and R values
CALVIN TRAN
06/05/2026
Special inspection requirement — HVAC-R and service water heating system controls
CALVIN TRAN
06/05/2026
Special inspection requirement — Interior lighting power
CALVIN TRAN
06/05/2026
Special inspection requirement — Fenestration areas
CALVIN TRAN
06/05/2026
Special inspection requirement — Air barrier - visual inspection
CALVIN TRAN
06/05/2026
Special inspection requirement — Maintenance information
CALVIN TRAN
06/05/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
CALVIN TRAN
06/05/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
CALVIN TRAN
06/05/2026
Special inspection requirement — Fenestration air leakage
CALVIN TRAN
06/03/2026
Filed — Alteration
EXISTING 2-FAMILY HOUSE WITH INTERIOR RENOVATION ON PARTITION,MECHANICAL WORK AT THE BASEMENT, 1ST, 2ND FLOOR AND OPEN SPACEUNDER THIS APPLICATION. INSTALL A NEW BULKHEAD. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THISAPPLICATION.
B01289021-P4
05/14/2026
Filed — Alteration
EXISTING 2-FAMILY HOUSE WITH INTERIOR RENOVATION ON PARTITION,MECHANICAL WORK AT THE BASEMENT, 1ST, 2ND FLOOR AND OPEN SPACEUNDER THIS APPLICATION. INSTALL A NEW BULKHEAD. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THISAPPLICATION.
B01289021-P3
05/11/2026
Violation issued (ECB, closed)
Construction
04/20/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/15/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/01/2026
Filed — Alteration
EXISTING 2-FAMILY HOUSE WITH INTERIOR RENOVATION ON PARTITION,MECHANICAL WORK AT THE BASEMENT, 1ST, 2ND FLOOR AND OPEN SPACEUNDER THIS APPLICATION. INSTALL A NEW BULKHEAD. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THISAPPLICATION.
B01289021-P2
03/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SIMON JIANG
03/02/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SIMON JIANG
03/02/2026
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
03/02/2026
Special inspection requirement — Air barrier - visual inspection
CALVIN TRAN
03/02/2026
Special inspection requirement — HVAC-R and service water heating system controls
CALVIN TRAN
03/02/2026
Special inspection requirement — Final
CALVIN TRAN
03/02/2026
Special inspection requirement — Fire-Resistance Rated Construction
CALVIN TRAN
03/02/2026
Special inspection requirement — Structural Wood Frame
CALVIN TRAN
03/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
03/02/2026
Special inspection requirement — Fenestration air leakage
CALVIN TRAN
03/02/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
CALVIN TRAN
03/02/2026
Special inspection requirement — Interior lighting power
CALVIN TRAN
03/02/2026
Special inspection requirement — Metering
CALVIN TRAN
02/13/2026
Filed — Alteration
EXISTING 2-FAMILY HOUSE WITH INTERIOR RENOVATION ON PARTITION,MECHANICAL WORK AT THE BASEMENT, 1ST, 2ND FLOOR AND OPEN SPACEUNDER THIS APPLICATION. INSTALL A NEW BULKHEAD. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THISAPPLICATION.
B01289021-P1
12/01/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/01/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/01/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/25/2025
Violation issued (ECB, closed)
Construction
10/02/2025
Permit issued — General Construction
B01289021-I1-GC-CX
10/01/2025
Permit issued — Plumbing
B01289021-S1-PL
09/26/2025
Filed — Alteration
EXISTING 2-FAMILY HOUSE WITH INTERIOR RENOVATION ON PARTITION,MECHANICAL WORK AT THE BASEMENT, 1ST, 2ND FLOOR AND OPEN SPACEUNDER THIS APPLICATION. INSTALL A NEW BULKHEAD. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THISAPPLICATION.
B01289021-I1
09/26/2025
Filed — Alteration
EXISTING 2-FAMILY HOUSE WITH INTERIOR RENOVATION ON PARTITION,MECHANICAL WORK AT THE BASEMENT, 1ST, 2ND FLOOR AND OPEN SPACEUNDER THIS APPLICATION. INSTALL A NEW BULKHEAD. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THISAPPLICATION.
B01289021-S1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offMORELL BUILDERS INC10/02/2025
DOB NOWPlumbingSigned-offPLBG P & H INC10/01/2025
1 project · most recent 06/03/2026
Gas Water/Sanitary
FiledStatusContractorScope
06/03/2026Signed-offPLBG P & H INCGas, Water/Sanitary
1 project · most recent 06/09/2026
General Wiring
FiledStatusContractorScope
06/09/2026CompleteC & A ELECTRICAL CORPGeneral Wiring
1 project · most recent 06/03/2026
Wood
FiledStatusContractorScope
06/03/2026Signed-offMORELL BUILDERS INCWood
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/20/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/15/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/01/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/01/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/01/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 39
DateRequirementInspectorRole
06/05/2026Structural Stability – Alterations of existing buildingsSIMON JIANGspecial
06/05/2026Fire-Resistant Penetrations and JointsSIMON JIANGspecial
06/05/2026Structural Wood FrameCALVIN TRANprogress
06/05/2026FinalCALVIN TRANprogress
06/05/2026Fire-Resistance Rated ConstructionCALVIN TRANprogress
06/05/2026Energy Code Compliance InspectionsCALVIN TRANprogress
06/05/2026MeteringCALVIN TRANenergy_progress
06/05/2026HVAC-R and service water heating equipmentCALVIN TRANenergy_progress
06/05/2026Insulation placement and R valuesCALVIN TRANenergy_progress
06/05/2026HVAC-R and service water heating system controlsCALVIN TRANenergy_progress
06/05/2026Interior lighting powerCALVIN TRANenergy_progress
06/05/2026Fenestration areasCALVIN TRANenergy_progress
06/05/2026Air barrier - visual inspectionCALVIN TRANenergy_progress
06/05/2026Maintenance informationCALVIN TRANenergy_progress
06/05/2026HVAC-R and service water piping design and insulationCALVIN TRANenergy_progress
06/05/2026Fenestration and door U-factor and product ratingsCALVIN TRANenergy_progress
06/05/2026Fenestration air leakageCALVIN TRANenergy_progress
03/02/2026Fire-Resistant Penetrations and JointsSIMON JIANGspecial
03/02/2026Structural Stability – Alterations of existing buildingsSIMON JIANGspecial
03/02/2026Energy Code Compliance InspectionsCALVIN TRANprogress
03/02/2026Air barrier - visual inspectionCALVIN TRANenergy_progress
03/02/2026HVAC-R and service water heating system controlsCALVIN TRANenergy_progress
03/02/2026FinalCALVIN TRANprogress
03/02/2026Fire-Resistance Rated ConstructionCALVIN TRANprogress
03/02/2026Structural Wood FrameCALVIN TRANprogress
Latest 25 of 39.
▾Documents — 57 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/16/2026B01289021-I1Request digital key ↗
08/16/2026B01289021-P4Request digital key ↗
08/16/2026B01289021-S1Request digital key ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications45
▸DOB NOWProgress Inspector Seal & Signature35
09/02/2026B01289021-S1Open ↗
09/02/2026B01289021-S1Open ↗
09/02/2026B01289021-S1Open ↗
Showing 3 of 35 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/16/2026B01289021-I1Open ↗
08/16/2026B01289021-S1Open ↗
08/16/2026B01289021-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026B01289021-P2Open ↗
09/01/2026B01289021-P2Open ↗
08/23/2026B01289021-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/16/2026B01289021-P4Open ↗
08/16/2026B01289021-P3Open ↗
08/16/2026B01289021-I1Open ↗