← Back
BuildNYC
Four families
737 GREENWICH STREET
MANHATTAN · West Village · BIN 1011872
💬 Discuss this project
1838Year Built
2.5Stories
C3Building Class
C1-6Zoning
1,330 sfGross Floor Area
4Units
0 Active ViolationsFDNY Report ↗
Four families · 1,330 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof13p · 1 filing · 20 docs
Floor 320p · 1 filing · 20 docs
Floor 2Unit 218p · 1 filing · 20 docs
Floor 1
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/30/2025$1.6M—Private party → Private party$1,241/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Satwin Architect502/09/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Satwin Architect1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Home Improvement JimenezGeneral Contractor407/08/2026
?Leonard SchiffmanElectrical203/21/2026
Triple H ElectricalElectrical203/22/2026
Triple H ElectricalElectrical103/21/2026
Gregg NY PlumbingPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Satwin Architect7107310/09/2025
Socotec Engineering4983107/14/2025
Building Lifecycle
07/03/2026
Permit expired, never signed off — Plumbing
The city's record still shows this permit as issued, with no sign-off on its filing
M01199893-S1-PL
05/27/2026
Permit expired, never signed off — Structural
The city's record still shows this permit as issued, with no sign-off on its filing
M01199893-I1-GC
05/27/2026
Permit expired, never signed off — Structural
The city's record still shows this permit as issued, with no sign-off on its filing
M01199893-I1-ST
02/15/2026
Special inspection requirement — Energy Code Compliance Inspections
Marta Satwin-Ramberg
02/15/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Marta Satwin-Ramberg
59 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedHome Improvement Jimenez09/12/2025
DOB NOWMechanical SystemsSigned-offHome Improvement Jimenez09/11/2025
DOB NOWStructuralPermit IssuedHome Improvement Jimenez08/20/2025
DOB NOWPlumbingPermit IssuedGregg NY Plumbing07/03/2025
DOB NOWGeneral ConstructionPermit IssuedHome Improvement Jimenez06/05/2025
BISPLISSUEDTri City Mechanical Group07/08/2004
BIS—ISSUEDBucklley Contracting10/14/2003
BISPLISSUEDTri City Mechanical Group10/14/2003
BISOTISSUEDBuckley Contracting07/17/2003
1 project · most recent 02/09/2026
Air Conditioning Systems
FiledStatusContractorScope
02/09/2026Permit IssuedHome Improvement JimenezAir Conditioning Systems
1 project · most recent 02/09/2026
Gas Water/Sanitary
FiledStatusContractorScope
02/09/2026Permit IssuedGregg NY PlumbingGas, Water/Sanitary
1 project · most recent 06/12/2025
General Wiring
FiledStatusContractorScope
06/12/2025CompleteTriple H ElectricalGeneral Wiring
1 project · most recent 02/09/2026
FiledStatusContractorScope
02/09/2026Permit IssuedHome Improvement Jimenez—
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/06/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/22/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/20/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/20/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/15/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 33
DateRequirementInspectorRole
02/15/2026Energy Code Compliance InspectionsMarta Satwin-Rambergprogress
02/15/2026HVAC-R and service water piping design and insulationMarta Satwin-Rambergenergy_progress
10/17/2025Lighting in dwelling unitsMarta Satwin-Rambergenergy_progress
10/17/2025Fire-Resistant Penetrations and JointsMarta Satwin-Rambergspecial
10/17/2025Lighting controlsMarta Satwin-Rambergenergy_progress
10/17/2025Fenestration areasMarta Satwin-Rambergenergy_progress
10/17/2025Interior lighting powerMarta Satwin-Rambergenergy_progress
10/17/2025Fenestration air leakageMarta Satwin-Rambergenergy_progress
10/17/2025Fenestration and door U-factor and product ratingsMarta Satwin-Rambergenergy_progress
10/17/2025Energy Code Compliance InspectionsMarta Satwin-Rambergprogress
10/17/2025MeteringMarta Satwin-Rambergenergy_progress
10/17/2025FinalMarta Satwin-Rambergprogress
10/17/2025Air barrier - visual inspectionMarta Satwin-Rambergenergy_progress
10/08/2025Lighting controlsMarta Satwin-Rambergenergy_progress
10/08/2025Fire-Resistant Penetrations and JointsMarta Satwin-Rambergspecial
10/08/2025Energy Code Compliance InspectionsMarta Satwin-Rambergprogress
10/08/2025FinalMarta Satwin-Rambergprogress
10/08/2025Lighting in dwelling unitsMarta Satwin-Rambergenergy_progress
10/08/2025Interior lighting powerMarta Satwin-Rambergenergy_progress
10/08/2025MeteringMarta Satwin-Rambergenergy_progress
10/08/2025Fenestration air leakageMarta Satwin-Rambergenergy_progress
10/08/2025Fenestration areasMarta Satwin-Rambergenergy_progress
10/08/2025Fenestration and door U-factor and product ratingsMarta Satwin-Rambergenergy_progress
10/08/2025Air barrier - visual inspectionMarta Satwin-Rambergenergy_progress
06/18/2025Fire-Resistant Penetrations and JointsMarta Satwin-Rambergspecial
Latest 25 of 33.
35 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account