| Owner | Filings | Most Recent |
|---|---|---|
| ZHENG CLAN USA INC. | 1 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 09/04/2025 | $1.5M | — | — → — | $549/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| JX FLAME SOLUTION INC | 4 | 11/14/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| VIBEN BUILDING | 8 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| JABBIE INDUSTRIES INCORP* | General Contractor | 4 | 04/09/2026 |
| FLUSHING PLUMBING CORP | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| JX FLAME SOLUTION INC | 7286 | 2 | 09/30/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Permit Issued | FLUSHING PLUMBING CORP | 01/07/2026 |
| DOB NOW | General Construction | Signed-off | JABBIE INDUSTRIES INCORP* | 11/05/2025 |
| DOB NOW | Construction Fence | Signed-off | JABBIE INDUSTRIES INCORP* | 09/30/2025 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/14/2025 | Permit Issued | FLUSHING PLUMBING CORP | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/19/2025 | Complete | KJK ELECTRIC INC | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/25/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 08/18/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/06/2026 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 04/01/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 03/20/2026 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 03/04/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 03/02/2026 | Pass-Final PL - Underground | Pass | View ↗ |
| 10/04/2023 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 10/04/2023 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 08/15/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 12/09/2025 | Fire-Resistant Penetrations and Joints | JIE ZHU | special |
| 12/09/2025 | Energy Code Compliance Inspections | JIE ZHU | progress |
| 12/09/2025 | HVAC-R and service water heating equipment | JIE ZHU | energy_progress |
| 12/09/2025 | HVAC-R and service water piping design and insulation | JIE ZHU | energy_progress |
| 12/09/2025 | HVAC-R and service water heating system controls | JIE ZHU | energy_progress |
| 11/14/2025 | Fire-Resistant Penetrations and Joints | — | special |
| 11/14/2025 | Energy Code Compliance Inspections | — | progress |
| 11/14/2025 | HVAC-R and service water heating system controls | — | energy_progress |
| 11/14/2025 | HVAC-R and service water heating equipment | — | energy_progress |
| 11/14/2025 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 09/29/2025 | Fire-Resistant Penetrations and Joints | JIE ZHU | special |
| 09/29/2025 | Energy Code Compliance Inspections | JIE ZHU | progress |
| 09/29/2025 | Fire-Resistance Rated Construction | JIE ZHU | progress |
| 09/29/2025 | Fenestration and door U-factor and product ratings | JIE ZHU | energy_progress |
| 09/29/2025 | Fenestration areas | JIE ZHU | energy_progress |
| 09/29/2025 | Interior lighting power | JIE ZHU | energy_progress |