← Back
Three families
739 EAST 181 STREET
BRONX · Tremont · BIN 2113727
💬 Discuss this project
2002Year Built
3Stories
C0Building Class
R7-1Zoning
2,025 sfGross Floor Area
3Units
Three families · 1,718 sf lot · 1.18 FAR built · Flood zone X
Locations of Work
Electrical
Roof1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HPD603/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR107/28/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ISLAND ELECTRIC CORP 004835General Contractor403/22/2026
ISLAND ELECTRIC CORPElectrical103/22/2026
JEFFREY MARINELLOElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV SIA LLC9281107/28/2025
Building Lifecycle
All (7)Filed (1)Permit Issued (1)Special Inspection (5)
07/30/2025
Permit issued — Solar
X01262224-I1-SL
07/28/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS, ROOFTOP,RAILED, GRID-TIED, 17 MODULES, 7.31KW
X01262224-I1
07/28/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
07/28/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mina Makar
07/28/2025
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
07/28/2025
Special inspection requirement — Final
Mina Makar
07/28/2025
Special inspection requirement — Air barrier - visual inspection
Mina Makar
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedMOMENTUM SOLAR07/30/2025
BISPLISSUEDAMERICAN MECHANICAL CORP.09/24/2003
BIS—ISSUEDFALCON CONSTRUCTION04/21/2003
BIS—ISSUEDFALCON CONSTRUCTION11/19/2002
BISPLISSUEDAMERICAN MECHANICAL CORP.04/02/2002
BIS—ISSUEDFALCON CONSTRUCTION02/21/2002
1 project · most recent 12/19/2025
FiledStatusContractorScope
12/19/2025CompleteISLAND ELECTRIC CORP—
1 project · most recent 07/28/2025
FiledStatusContractorScope
07/28/2025Permit IssuedMOMENTUM SOLAR34 panels, 14.62 kw, 299 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/28/2025Fire-Resistant Penetrations and JointsMina Makarspecial
07/28/2025Structural Stability – Alterations of existing buildingsMina Makarspecial
07/28/2025Energy Code Compliance InspectionsMina Makarprogress
07/28/2025FinalMina Makarprogress
07/28/2025Air barrier - visual inspectionMina Makarenergy_progress
▾Documents — 5 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026X01262224-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026X01262224-I1Open ↗
09/01/2026X01262224-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/18/2026X01262224-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026X01262224-I1Open ↗