← Back
Over six families without stores
739 WYONA STREET
BROOKLYN · East New York-New Lots · BIN 3097404
💬 Discuss this project
1930Year Built
2Stories
C1Building Class
R6Zoning
4,085 sfGross Floor Area
8Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Over six families without stores · Owner of record: WYONA RESIDENCE LLC · 2,550 sf lot · 1.6 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Roof46p · 1 filing · 20 docs
Floor 268p · 1 filing · 20 docs
Floor 168p · 1 filing · 20 docs
Basement39p · 1 filing · 20 docs
Sub-Basement63p · 1 filing · 20 docs
Site & exterior5p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WYONA RESIDENCE LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/08/2022$800K—Private party → WYONA RESIDENCE LLC$196/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEANDRO NILS DICKSON ARCHITECT, LLC1005/07/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPEDITING 4 U1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MJH CONSTRUCTION CORPGeneral Contractor603/21/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
MPI PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP56161205/07/2023
Building Lifecycle
All (105)Filed (10)Permit Issued (5)Signed Off (4)Violation (7)Inspection (9)Objection (40)Special Inspection (30)
07/10/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/22/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT SPRINKLER APPLICATION FILED HEREWITH.
B00747737-S4
06/16/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT SPRINKLER APPLICATION FILED HEREWITH.
B00747737-S2
05/31/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT SPRINKLER APPLICATION FILED HEREWITH.
B00747737-S3
05/23/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
05/19/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
05/14/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT SPRINKLER APPLICATION FILED HEREWITH.
B00747737-S1
05/07/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT SPRINKLER APPLICATION FILED HEREWITH.
B00747737-P5
05/05/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
05/05/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
05/05/2023
Special inspection requirement — Duct leakage testing, insulation and design
FAHAD FATEH
05/05/2023
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
05/05/2023
Special inspection requirement — Ventilation and air distribution system
FAHAD FATEH
05/05/2023
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
05/05/2023
Special inspection requirement — Final
FAHAD FATEH
05/05/2023
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
05/05/2023
Special inspection requirement — Mechanical Systems
FAHAD FATEH
05/03/2023
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
05/03/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/03/2023
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
05/03/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
05/03/2023
Special inspection requirement — Sprinkler Systems
FAHAD FATEH
05/02/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT SPRINKLER APPLICATION FILED HEREWITH.
B00747737-P4
05/02/2023
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
05/02/2023
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
05/02/2023
Special inspection requirement — Air barrier — testing
FAHAD FATEH
05/02/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
05/02/2023
Special inspection requirement — Metering
FAHAD FATEH
05/02/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
FAHAD FATEH
05/02/2023
Special inspection requirement — Fenestration areas
FAHAD FATEH
05/02/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
05/02/2023
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
05/02/2023
Special inspection requirement — Air barrier - visual inspection
FAHAD FATEH
05/02/2023
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
05/02/2023
Special inspection requirement — Interior lighting power
FAHAD FATEH
05/02/2023
Special inspection requirement — Maintenance information
FAHAD FATEH
05/02/2023
Special inspection requirement — Permanent certificate
FAHAD FATEH
05/01/2023
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
05/01/2023
Special inspection requirement — Final
FAHAD FATEH
05/01/2023
Special inspection requirement — Mechanical Systems
FAHAD FATEH
05/01/2023
Special inspection requirement — Duct leakage testing, insulation and design
FAHAD FATEH
04/28/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT SPRINKLER APPLICATION FILED HEREWITH.
B00747737-P2
04/28/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT SPRINKLER APPLICATION FILED HEREWITH.
B00747737-P3
04/28/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/27/2023
Violation issued (HPD, closed)
A
02/22/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/14/2023
Permit issued — Mechanical Systems
B00747737-S1-MS
02/14/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/31/2023
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
01/26/2023
Permit issued — General Construction
B00747737-S4-GC-CX
01/24/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT SPRINKLER APPLICATION FILED HEREWITH.
B00747737-P1
01/17/2023
Permit issued — Sprinklers
B00747737-S3-EW-SP
01/13/2023
Permit issued — Plumbing
B00747737-S2-PL
12/29/2022
Objection raised — Scope
12/29/2022
Objection resolved — Addressed
12/28/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT SPRINKLER APPLICATION FILED HEREWITH.
B00747737-S4
12/16/2022
Permit issued — General Construction
B00747737-I1-GC
10/05/2022
Objection raised — Other
10/05/2022
Objection resolved — Addressed
07/20/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT SPRINKLER APPLICATION FILED HEREWITH.
B00747737-S2
Latest 60 of 105 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offMJH CONSTRUCTION CORP02/14/2023
DOB NOWGeneral ConstructionSigned-offMJH CONSTRUCTION CORP01/26/2023
DOB NOWSprinklersSigned-offA M B MECHANICAL INC01/17/2023
DOB NOWPlumbingSigned-offYG SERVICES INC01/13/2023
DOB NOWGeneral ConstructionPermit IssuedMJH CONSTRUCTION CORP12/16/2022
1 project · most recent 05/07/2023
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/07/2023Signed-offMJH CONSTRUCTION CORPAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Mitsubishi Electric MUZ-GL12NA 12,000 BTU · Condensing Unit ×4
MUZ-GL15NA 15,000 BTU · Condensing Unit ×3
MXZ-2C20NA3 18,000 BTU · Condensing Unit ×2
Heating
Mitsubishi Electric MUZ-GL12NA 14,400 BTU · Condensing Unit ×4
MUZGL-15NA 18,300 BTU · Condensing Unit ×3
MXZ-2C20NA3 18,900 BTU · Condensing Unit ×2
Ventilation
Nutone AEN110 50 CFM · Exhaust Fan ×8
QTXEN150 100 CFM · Exhaust Fan ×8
1 project · most recent 06/01/2023
General Wiring
FiledStatusContractorScope
06/01/2023CompleteS&R ELECTRICAL & MECHANICGeneral Wiring
1 project · most recent 05/07/2023
Steel Concrete
FiledStatusContractorScope
05/07/2023Signed-offMJH CONSTRUCTION CORPSteel, Concrete
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
07/10/2023Pass-Final CND-Occupancy InspectionPassView ↗
05/23/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
05/19/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/03/2023Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
05/03/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/28/2023Pass-Final CND-Occupancy InspectionPassView ↗
02/22/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/14/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/31/2023Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 64
DateRequirementInspectorRole
05/05/2023HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
05/05/2023Ventilation and air distribution systemFAHAD FATEHenergy_progress
05/05/2023Duct leakage testing, insulation and designFAHAD FATEHenergy_progress
05/05/2023Mechanical SystemsFAHAD FATEHspecial
05/05/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
05/05/2023FinalFAHAD FATEHprogress
05/05/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
05/05/2023HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
05/05/2023HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
05/03/2023Post-installed AnchorsFAHAD FATEHspecial
05/03/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
05/03/2023Sprinkler SystemsFAHAD FATEHspecial
05/02/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
05/02/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
05/02/2023Exterior Insulation and Finish Systems (EIFS)FAHAD FATEHspecial
05/02/2023Permanent certificateFAHAD FATEHenergy_progress
05/02/2023Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
05/02/2023MeteringFAHAD FATEHenergy_progress
05/02/2023Maintenance informationFAHAD FATEHenergy_progress
05/02/2023Air barrier - visual inspectionFAHAD FATEHenergy_progress
05/02/2023Insulation placement and R valuesFAHAD FATEHenergy_progress
05/02/2023Interior lighting powerFAHAD FATEHenergy_progress
05/02/2023Fenestration areasFAHAD FATEHenergy_progress
05/02/2023Fenestration air leakageFAHAD FATEHenergy_progress
05/02/2023Air barrier — testing FAHAD FATEHenergy_progress
Latest 25 of 64.
▾Documents — 67 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/28/2026B00747737-P3Request digital key ↗
08/28/2026B00747737-P2Request digital key ↗
08/28/2026B00747737-P1Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00747737-I1Open ↗
▸Seals & Professional Certifications34
▸DOB NOWSpecial Inspector Seal & Signature14
08/28/2026B00747737-P5Open ↗
08/28/2026B00747737-P5Open ↗
08/28/2026B00747737-P2Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/28/2026B00747737-S4Open ↗
08/28/2026B00747737-P2Open ↗
08/28/2026B00747737-P1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature10
08/28/2026B00747737-P5Open ↗
08/28/2026B00747737-P5Open ↗
08/28/2026B00747737-P2Open ↗
Showing 3 of 10 on file for this type
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
08/28/2026B00747737-P2Open ↗
08/28/2026B00747737-P1Open ↗
08/28/2026B00747737-S3Open ↗
Showing 3 of 10 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00747737-I1Open ↗
▸Inspections & Test Reports3
▸DOB NOWHydrant Flow Test Letter3
08/28/2026B00747737-S3Open ↗
08/28/2026B00747737-P3Open ↗
08/15/2026B00747737-P3Open ↗
▸Other Documents8
▸DOB NOWSite Survey: Initial4
08/13/2026B00747737-S4Open ↗
08/13/2026B00747737-P1Open ↗
08/13/2026B00747737-P5Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWHydraulic Calculations2
08/13/2026B00747737-S3Open ↗
08/13/2026B00747737-P3Open ↗
▸DOB NOWProperty Ownership Certification2
08/28/2026B00747737-P5Open ↗
08/15/2026B00747737-I1Open ↗