← Back
Three families
74-17 46 AVENUE
QUEENS · BIN 4038210
💬 Discuss this project
1975Year Built
3Stories
C0Building Class
R5Zoning
2,850 sfGross Floor Area
3Units
Rent Stabilized7 Open Violations ▸
Three families · 2,400 sf lot · 1.19 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/10/2023$1.4M—— → —$491/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PONDOSA DESIGN INC202/10/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J. CAIAZZO PLBG & HTG CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PONDOSA DESIGN INC.5126202/10/2022
Building Lifecycle
All (26)Filed (2)Permit Issued (1)Signed Off (1)Violation (16)Special Inspection (6)
11/25/2025
Violation issued (HPD, open)
I
12/04/2024
Violation issued (HPD, open)
I
11/29/2023
Violation issued (HPD, open)
I
02/07/2023
Signed off — Alteration
PLUMBING WORK TYPE FILED IN CONJUNCTION WITH ALT 2 #440619804; NO CHANGE IN USE GROUP, EGRESS OR OCCUPANCY.
Q00385406-I1
02/10/2022
Filed — Alteration
PLUMBING WORK TYPE FILED IN CONJUNCTION WITH ALT 2 #440619804; NO CHANGE IN USE GROUP, EGRESS OR OCCUPANCY.
Q00385406-P1
02/10/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
MANG WONG
02/10/2022
Special inspection requirement — Energy Code Compliance Inspections
MANG WONG
02/10/2022
Special inspection requirement — Maintenance information
MANG WONG
02/10/2022
Special inspection requirement — HVAC and service water heating system controls
MANG WONG
02/10/2022
Special inspection requirement — HVAC and service water heating equipment
MANG WONG
02/10/2022
Special inspection requirement — HVAC insulation and sealing
MANG WONG
02/16/2021
Permit issued — Plumbing
Q00385406-I1-PL
08/20/2020
Filed — Alteration
PLUMBING WORK TYPE FILED IN CONJUNCTION WITH ALT 2 #440619804; NO CHANGE IN USE GROUP, EGRESS OR OCCUPANCY.
Q00385406-I1
05/04/2011
Violation issued (ECB, closed)
Unknown
03/08/2011
Violation issued (ECB, closed)
Unknown
02/23/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/02/2010
Violation issued (ECB, closed)
Unknown
12/02/2010
Violation issued (ECB, closed)
Unknown
10/12/2010
Violation issued (ECB, closed)
Construction
10/12/2010
Violation issued (ECB, closed)
Construction
10/06/2010
Violation issued (HPD, open)
B
10/06/2010
Violation issued (HPD, open)
B
10/06/2010
Violation issued (HPD, open)
B
10/06/2010
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJ. CAIAZZO PLBG & HTG COR02/16/2021
BISOTISSUEDDHC CONTRACTING INC08/16/2021
BISOTISSUEDDHC CONTRACTING INC02/17/2021
1 project · most recent 03/31/2021
General Wiring
FiledStatusContractorScope
03/31/2021CompleteCOMBINED ELECL CONTNG INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
02/10/2022Fire-Resistant Penetrations and JointsMANG WONGspecial
02/10/2022Energy Code Compliance InspectionsMANG WONGprogress
02/10/2022Maintenance informationMANG WONGenergy_progress
02/10/2022HVAC and service water heating system controls MANG WONGenergy_progress
02/10/2022HVAC and service water heating equipment MANG WONGenergy_progress
02/10/2022HVAC insulation and sealing MANG WONGenergy_progress
▾Documents — 32 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Plumbing2
08/28/2026Q00385406-I1Request digital key ↗
08/15/2026Q00385406-P1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
11/23/2020440619804Open ↗
10/21/2020440619804Open ↗
▸BISWORK PERMIT APPLICATION1
02/17/2021440619804Open ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature5
08/23/2026Q00385406-P1Open ↗
08/23/2026Q00385406-P1Open ↗
08/23/2026Q00385406-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q00385406-P1Open ↗
08/13/2026Q00385406-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026Q00385406-P1Open ↗
▸Environmental & Asbestos4
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
12/04/2020440619804Open ↗
08/21/2020440619804Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q00385406-I1Open ↗
08/13/2026Q00385406-P1Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
01/27/2023440619804Open ↗
02/17/2021440619804Open ↗
12/04/2020440619804Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
01/27/2023440619804Open ↗
▸Inspections & Test Reports5
▸BISTECHNICAL REPORT: RESPONSIBILITY5
01/28/2023440619804Open ↗
01/27/2023440619804Open ↗
02/17/2021440619804Open ↗
Showing 3 of 5 on file for this type
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/24/2025440619804Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
01/27/2023440619804Open ↗
11/16/2020440619804Open ↗
08/21/2020440619804Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION2
12/04/2020440619804Open ↗
11/16/2020440619804Open ↗