← Back
Primarily 2 family with 1 store or office
74-24 JAMAICA AVENUE
QUEENS · Woodhaven · BIN 4182900
💬 Discuss this project
1930Year Built
2Stories
S2Building Class
R6AZoning
2,480 sfGross Floor Area
3Units
Rent Stabilized16 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: 74-24 JAMAICA CORP · 2,145 sf lot · 1.16 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
Floor 2Under Construction7p · 1 filing · 20 docs
Floor 1Under Construction3p · 1 filing · 20 docs
CellarUnder Construction4p · 1 filing · 20 docs
Site & exteriorUnder Construction1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FELIPE ASSOCIATES2107/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KENNY LEE ARCHITECT702/06/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KORMAN DESIGN & BUILD1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SEBA HOLDINGS LLCGeneral Contractor603/21/2026
GLENNS PLUMBING SVCS INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KORMAN DESIGN & BUILD2055702/06/2024
Building Lifecycle
All (74)Filed (7)Permit Issued (4)Violation (20)Inspection (7)Objection (6)Special Inspection (30)
02/20/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/31/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/31/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/12/2025
Permit issued — Plumbing
Q00703031-S1-PL
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/04/2024
Special inspection requirement — Concrete - Cast-In-Place
DAVID UH
03/04/2024
Special inspection requirement — Structural Steel - Welding
DAVID UH
03/04/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
DAVID UH
03/04/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DAVID UH
03/04/2024
Special inspection requirement — Heating Systems
DAVID UH
03/04/2024
Special inspection requirement — Mechanical Systems
DAVID UH
03/04/2024
Special inspection requirement — Structural Steel - Details
DAVID UH
03/04/2024
Special inspection requirement — Energy Code Compliance Inspections
DAVID UH
03/04/2024
Special inspection requirement — Final
DAVID UH
03/04/2024
Special inspection requirement — Interior lighting power
DAVID UH
03/04/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
DAVID UH
03/04/2024
Special inspection requirement — HVAC-R and service water heating system controls
DAVID UH
03/04/2024
Special inspection requirement — Lighting controls
DAVID UH
03/04/2024
Special inspection requirement — HVAC-R and service water heating equipment
DAVID UH
03/04/2024
Special inspection requirement — Metering
DAVID UH
02/22/2024
Objection resolved — Addressed
02/13/2024
Objection raised — Energy
02/06/2024
Filed — Alteration CO
BUILDING C/O CHANGE ON FIRST FLOOR FROM STORE TO BUSINESS OFFICE , SECOND FLOOR STAY SAME AS TWO FAMILY .
Q00703031-P6
02/06/2024
Filed — Alteration CO
BUILDING C/O CHANGE ON FIRST FLOOR FROM STORE TO BUSINESS OFFICE , SECOND FLOOR STAY SAME AS TWO FAMILY .
Q00703031-P7
01/23/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DAVID UH
01/23/2024
Special inspection requirement — Energy Code Compliance Inspections
DAVID UH
01/23/2024
Special inspection requirement — HVAC-R and service water heating equipment
DAVID UH
01/23/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
DAVID UH
01/23/2024
Special inspection requirement — HVAC-R and service water heating system controls
DAVID UH
01/22/2024
Special inspection requirement — Concrete - Cast-In-Place
DAVID UH
01/22/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DAVID UH
01/22/2024
Special inspection requirement — Heating Systems
DAVID UH
01/22/2024
Special inspection requirement — Mechanical Systems
DAVID UH
01/22/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
DAVID UH
01/22/2024
Special inspection requirement — Structural Steel - Details
DAVID UH
01/22/2024
Special inspection requirement — Structural Steel - Welding
DAVID UH
01/22/2024
Special inspection requirement — Energy Code Compliance Inspections
DAVID UH
01/22/2024
Special inspection requirement — Final
DAVID UH
01/22/2024
Special inspection requirement — HVAC-R and service water heating system controls
DAVID UH
11/17/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/28/2023
Permit issued — Structural
Q00703031-I1-GC-CX
06/23/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/23/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/21/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/24/2023
Permit issued — Plumbing
Q00703031-S1-PL
12/28/2022
Filed — Alteration CO
BUILDING C/O CHANGE ON FIRST FLOOR FROM STORE TO BUSINESS OFFICE , SECOND FLOOR STAY SAME AS TWO FAMILY .
Q00703031-P5
12/28/2022
Filed — Alteration CO
BUILDING C/O CHANGE ON FIRST FLOOR FROM STORE TO BUSINESS OFFICE , SECOND FLOOR STAY SAME AS TWO FAMILY .
Q00703031-P4
11/18/2022
Violation issued (HPD, closed)
I
07/14/2022
Permit issued — Mechanical Systems
Q00703031-I1-GC-CX
07/01/2022
Objection resolved — Addressed
06/15/2022
Objection raised — Accessibility
06/13/2022
Filed — Alteration CO
BUILDING C/O CHANGE ON FIRST FLOOR FROM STORE TO BUSINESS OFFICE , SECOND FLOOR STAY SAME AS TWO FAMILY .
Q00703031-P1
04/07/2022
Filed — Alteration CO
BUILDING C/O CHANGE ON FIRST FLOOR FROM STORE TO BUSINESS OFFICE , SECOND FLOOR STAY SAME AS TWO FAMILY .
Q00703031-S1
04/07/2022
Objection raised — Fire_Protection
Latest 60 of 74 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedGLENNS PLUMBING SVCS INC11/12/2025
DOB NOWStructuralPermit IssuedSEBA HOLDINGS LLC06/28/2023
DOB NOWPlumbingPermit IssuedGLENNS PLUMBING SVCS INC02/24/2023
DOB NOWMechanical SystemsPermit IssuedSEBA HOLDINGS LLC07/14/2022
1 project · most recent 02/06/2024
Air Conditioning Systems Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
02/06/2024Permit IssuedSEBA HOLDINGS LLCAir Conditioning Systems, Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MSZ-GL09NA 9,000 BTU · Fan Coil Indoor ×6
MSZ-GL24NA 24,000 BTU · Split System ×4
MXZ-3C30NA2 30,000 BTU · Heat Pump Outdoor ×2
MXZ-5C42NA2 42,000 BTU · Heat Pump Outdoor ×2
Gree 4LIV24HP230V1AH 24,000 BTU · Heat Pump Outdoor ×4
MULTI42HP230V1EO 40,000 BTU · Heat Pump Outdoor ×2
Carrier 24ACC660 60,000 BTU · Condensing Unit ×2
Rheem R801CA125524MSA 60,000 BTU · Furnace ×2
Ventilation
__Junk__ TBD 2,000 CFM · Exhaust Fan ×2
Cooling
Mitsubishi Electric MXZ-3C3ONA2 30,000 BTU · Condensing Unit ×1
MXZ-5C42NA2 42,000 BTU · Condensing Unit ×1
Carrier 24ACC660 60,000 BTU · Condensing Unit ×1
Heating
Mitsubishi Electric MSZ-GL09NA 9,000 BTU · Heat Pump Outdoor ×3
MSZ-GL24NA 24,000 BTU · Heat Pump Outdoor ×2
Luxaire G2FD060S24G 60,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 02/06/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
02/06/2024Permit IssuedGLENNS PLUMBING SVCS INCGas, Storm, Water/Sanitary
1 project · most recent 08/25/2020
FiledStatusContractorScope
08/25/2020Permit IssuedRM ELECTRIC CO., INC.4 meters, 4 new_meters
1 project · most recent 02/06/2024
Steel
FiledStatusContractorScope
02/06/2024Permit IssuedGLENNS PLUMBING SVCS INCSteel
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
02/20/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/31/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/31/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/17/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
06/23/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/23/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/21/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 50
DateRequirementInspectorRole
03/04/2024Concrete - Cast-In-PlaceDAVID UHspecial
03/04/2024Structural Steel - WeldingDAVID UHspecial
03/04/2024Structural Stability – Alterations of existing buildingsDAVID UHspecial
03/04/2024Fire-Resistant Penetrations and JointsDAVID UHspecial
03/04/2024Heating SystemsDAVID UHspecial
03/04/2024Mechanical SystemsDAVID UHspecial
03/04/2024Structural Steel - DetailsDAVID UHspecial
03/04/2024Energy Code Compliance InspectionsDAVID UHprogress
03/04/2024FinalDAVID UHprogress
03/04/2024Interior lighting powerDAVID UHenergy_progress
03/04/2024HVAC-R and service water piping design and insulationDAVID UHenergy_progress
03/04/2024HVAC-R and service water heating system controlsDAVID UHenergy_progress
03/04/2024Lighting controlsDAVID UHenergy_progress
03/04/2024HVAC-R and service water heating equipmentDAVID UHenergy_progress
03/04/2024MeteringDAVID UHenergy_progress
01/23/2024Fire-Resistant Penetrations and JointsDAVID UHspecial
01/23/2024Energy Code Compliance InspectionsDAVID UHprogress
01/23/2024HVAC-R and service water heating equipmentDAVID UHenergy_progress
01/23/2024HVAC-R and service water piping design and insulationDAVID UHenergy_progress
01/23/2024HVAC-R and service water heating system controlsDAVID UHenergy_progress
01/22/2024Concrete - Cast-In-PlaceDAVID UHspecial
01/22/2024Fire-Resistant Penetrations and JointsDAVID UHspecial
01/22/2024Heating SystemsDAVID UHspecial
01/22/2024Mechanical SystemsDAVID UHspecial
01/22/2024Structural Stability – Alterations of existing buildingsDAVID UHspecial
Latest 25 of 50.
▾Documents — 48 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/23/2026Q00703031-P4Request digital key ↗
08/23/2026Q00703031-S1Request digital key ↗
08/23/2026Q00703031-P8Request digital key ↗
Showing 3 of 8 on file for this type
▸Seals & Professional Certifications23
▸DOB NOWProgress Inspector Seal & Signature10
09/01/2026Q00703031-P6Open ↗
09/01/2026Q00703031-P6Open ↗
09/01/2026Q00703031-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/23/2026Q00703031-P1Open ↗
08/23/2026Q00703031-S1Open ↗
08/23/2026Q00703031-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/01/2026Q00703031-P6Open ↗
09/01/2026Q00703031-I1Open ↗
08/29/2026Q00703031-P7Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist4
08/13/2026Q00703031-P5Open ↗
08/13/2026Q00703031-P6Open ↗
08/13/2026Q00703031-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00703031-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/23/2026Q00703031-P8Open ↗
08/23/2026Q00703031-S1Open ↗
08/23/2026Q00703031-P7Open ↗
Showing 3 of 8 on file for this type
▸Other Documents4
▸DOB NOWProperty Ownership Certification4
08/23/2026Q00703031-P5Open ↗
08/15/2026Q00703031-P6Open ↗
08/15/2026Q00703031-I1Open ↗
Showing 3 of 4 on file for this type