← Back
Home for indigent children, aged, homeless
74 CLIFTON PLACE
BROOKLYN · BIN 3329903
💬 Discuss this project
1978Year Built
6Stories
N2Building Class
R6BZoning
—Gross Floor Area
150Units
32 Open Violations 31 unresolved · 1 paperwork only ▸FISP: UNSAFEFDNY Report ↗
Home for indigent children, aged, homeless · Owner of record: GREENE AVE 2012 BSRC HOUSING DEV FUND CO MPANY INC · 1.96 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
RoofUnder Construction1p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
JASCO707/08/2026
TUC MANAGEMENT107/04/2026
GREENE AVE 2012 BSRC HOUSING DEV FUND CO MPANY INC403/22/2026
GREENE AVE HOUSING DEVELO503/22/2026
GREENE AVENUE HOUSING HDFC303/22/2026
GREENE AVE HDFC CPR103/22/2026
GREENE AVENUE HDFC403/21/2026
MMS GROUP103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ADVANCED BUILDING CONSULTANTS103/26/2026
MJE PROFESSIONAL SERVICES104/18/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JASCO, INCGeneral Contractor507/08/2026
PROTECTOR BUILDER GENERALGeneral Contractor107/04/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FRAMEWORK ENGINEERING PC8217103/26/2026
Building Lifecycle
All (81)Filed (2)Permit Issued (4)Facade (FISP) (12)Violation (60)Special Inspection (3)
07/01/2026
Violation issued (HPD, open)
C
07/01/2026
Violation issued (HPD, closed)
B
07/01/2026
Violation issued (HPD, open)
A
04/20/2026
Violation issued (ECB, open)
Local Law
04/14/2026
Permit issued — General Construction
B01345461-I1-GC
04/02/2026
Violation issued (HPD, closed)
A
03/26/2026
Filed — Alteration
Facade restoration projects, as depicted in the provided plans.
B01345461-I1
03/24/2026
Special inspection requirement — Masonry
JAMES NAPOLI
03/24/2026
Special inspection requirement — Tenant Protection Plan Compliance
JAMES NAPOLI
01/15/2026
Permit issued — Sidewalk Shed
B01038034-I1-SH
01/13/2026
Violation issued (FDNY_NOV, closed)
01/12/2026
Special inspection requirement — Final
JAMES NAPOLI
04/07/2025
Violation issued (HPD, open)
C
04/07/2025
Violation issued (HPD, open)
B
04/07/2025
Violation issued (HPD, open)
B
04/07/2025
Violation issued (HPD, open)
C
04/07/2025
Violation issued (HPD, open)
B
04/07/2025
Violation issued (HPD, open)
C
04/07/2025
Violation issued (HPD, open)
B
04/07/2025
Violation issued (HPD, open)
B
03/20/2025
Permit issued — Sidewalk Shed
B01038034-I1-SH
08/01/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/27/2024
Cycle 9 facade report signed — UNSAFE
05/18/2024
Cycle 9 facade inspection completed
04/18/2024
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B01038034-I1
04/18/2024
Permit issued — Sidewalk Shed
B01038034-I1-SH
02/22/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/21/2024
Cycle 9 facade report submitted
02/21/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/18/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/16/2021
Violation issued (HPD, closed)
A
04/16/2021
Violation issued (HPD, closed)
I
01/29/2021
Violation issued (HPD, closed)
C
01/29/2021
Violation issued (HPD, closed)
B
01/29/2021
Violation issued (HPD, closed)
B
01/29/2021
Violation issued (HPD, closed)
A
01/29/2021
Violation issued (HPD, open)
B
01/29/2021
Violation issued (HPD, open)
C
09/25/2020
Violation issued (FDNY_NOV, closed)
09/25/2020
Violation issued (FDNY_NOV, closed)
09/25/2020
Violation issued (FDNY_NOV, closed)
09/23/2020
Violation issued (FDNY_NOV, closed)
07/08/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/04/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/27/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/27/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/27/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/27/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/27/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/17/2019
Violation issued (ECB, closed)
Elevators
06/10/2019
Violation issued (HPD, closed)
A
06/10/2019
Violation issued (HPD, closed)
A
02/20/2019
Cycle 8 facade report submitted
02/11/2019
Cycle 8 facade report signed — SWARMP
02/10/2019
Violation issued (HPD, closed)
C
02/06/2019
Cycle 8 facade inspection completed
12/19/2018
Violation issued (HPD, closed)
A
12/19/2018
Violation issued (HPD, closed)
B
12/19/2018
Violation issued (HPD, closed)
B
10/09/2018
Violation issued (HPD, closed)
C
Latest 60 of 81 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedPROTECTOR BUILDER GENERAL04/14/2026
DOB NOWSidewalk ShedPermit IssuedJASCO, INC01/15/2026
DOB NOWSidewalk ShedPermit IssuedJASCO, INC03/20/2025
DOB NOWSidewalk ShedPermit IssuedJASCO, INC04/18/2024
BISOTISSUEDPROCIDA CONSTRUCTION CORP.05/15/2013
BISPLISSUEDJ-J PLUMBING CORP03/12/2013
BISBLISSUEDJ-J PLUMBING CORP08/09/2012
BISOTISSUEDPROCIDA CONSTRUCTION CORP.05/14/2012
BISEQISSUEDTALICO CONSTRUCTION CORP04/25/2012
BISPLISSUEDJ-J PLUMBING CORP03/27/2012
BISOTISSUEDPROCIDA CONSTRUCTION CORP.12/09/2011
BISEQISSUEDOUTDOOR INST11/02/2007
BISOTISSUEDMCFAR CONTRACTORS10/18/2007
BISPLISSUEDMAXWELL PLUMB MECH. CORP11/03/2005
BISFBISSUEDRB HTG CONSULTING GROUP11/03/2005
BISFBISSUEDRB HTG CONSULTING GROUP10/08/2004
BISPLISSUEDMAXWELL PLUMB MECH. CORP09/24/2004
2 projects · most recent 04/19/2024
FiledStatusContractorScope
04/19/2024Permit IssuedRICHARD NEU—
02/25/2021Permit IssuedC.Q. ELECTR'L CONTRG CORP76 meters, 76 new_meters
1 project · most recent 04/18/2024
Sidewalk Shed
FiledStatusContractorScope
04/18/2024Permit IssuedJASCO, INCSidewalk Shed
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
03/24/2026MasonryJAMES NAPOLIspecial
03/24/2026Tenant Protection Plan ComplianceJAMES NAPOLIspecial
01/12/2026FinalJAMES NAPOLIprogress
▾Documents — 92 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026B01038034-I1Request digital key ↗
08/17/2026B01345461-I1Request digital key ↗
▸Applications & Permits15
▸BISWORK PERMIT APPLICATION9
12/17/2019322006486Open ↗
05/20/2013320389799Open ↗
08/10/2012320532045Open ↗
Showing 3 of 9 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION6
12/17/2019322006486Open ↗
08/12/2013320389799Open ↗
03/15/2013320389799Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications27
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION9
12/17/2019322006486Open ↗
08/12/2013320389799Open ↗
08/07/2012320532045Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST6
12/17/2019322006486Open ↗
08/07/2012320532045Open ↗
04/27/2012320468819Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM5
08/07/2012320532045Open ↗
04/27/2012320468819Open ↗
11/12/2011320389799Open ↗
Showing 3 of 5 on file for this type
▸BISPC FULL REPORT2
11/01/2007310043002Open ↗
10/17/2007310050574Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026B01345461-I1Open ↗
08/13/2026B01038034-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/17/2019322006486Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/26/2026B01345461-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026B01345461-I1Open ↗
▸Trade Schedules & Equipment5
▸BISSCHEDULE B - PLUMBING2
03/15/2013320389799Open ↗
11/12/2011320389799Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
03/29/2013320389799Open ↗
01/30/2013320389799Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
08/07/2012320532045Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
12/17/2019322006486Open ↗
▸Environmental & Asbestos7
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
11/12/2011320389799Open ↗
10/17/2007310050574Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
12/17/2019322006486Open ↗
12/17/2019322006486Open ↗
▸BISASBESTOS INSPECTION REPORT1
08/07/2012320532045Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
11/01/2007310043002Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/17/2026B01345461-I1Open ↗
▸Energy Compliance4
▸BISAS-BUILT ENERGY ANALYSIS2
07/27/2020322006486Open ↗
08/29/2013320389799Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
12/17/2019322006486Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/27/2020322006486Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/27/2020322006486Open ↗
▸Approvals, Objections & Sign-offs16
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST6
08/10/2020322006486Open ↗
09/17/2013320389799Open ↗
08/29/2013320389799Open ↗
Showing 3 of 6 on file for this type
▸BISADMINISTRATIVE OBJECTIONS5
08/07/2012320532045Open ↗
04/27/2012320468819Open ↗
11/12/2011320389799Open ↗
Showing 3 of 5 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION4
09/17/2013320389799Open ↗
08/20/2013320389799Open ↗
04/16/2013320468819Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter1
08/13/2026B01038034-I1Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
07/27/2020322006486Open ↗
12/17/2019322006486Open ↗
08/20/2013320389799Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms8
▸BISADDITIONAL INFORMATION4
01/28/2021322006486Open ↗
12/04/2012320532045Open ↗
11/20/2012320389799Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET4
12/16/2019322006486Open ↗
08/07/2012320532045Open ↗
04/27/2012320468819Open ↗
Showing 3 of 4 on file for this type