← Back
Single or multiple dwelling with stores or offices
74 QUENTIN ROAD
BROOKLYN · BIN 3176511
💬 Discuss this project
1931Year Built
2Stories
S9Building Class
R7AZoning
2,886 sfGross Floor Area
4Units
1 Open Violation ▸FDNY Report ↗
Single or multiple dwelling with stores or offices · Owner of record: LUCKY B&S LLC · 1,640 sf lot · 1.76 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 13p · 2 filings · 10 docs
Cellar4p · 2 filings · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LUCKY B&S LLC303/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/17/2019$1.3M—74 QUENTIN ROAD LLC → LUCKY B&S LLC$450/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALLEN SHINFELD, P.E. PLLC205/03/2022
JX FLAME SOLUTION INC102/28/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYX ENGINEERING, PLLC203/21/2026
PROJECT ENTRY203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MHLIN AND PARTNERS INCGeneral Contractor203/21/2026
LG ELITE PLUMBING INCPlumbing207/08/2026
HI-RITE ELECTRIC CORPElectrical103/22/2026
SPEZIALE, JOSEPHElectrical103/21/2026
CROSSFIELD PLBG.&HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALLEN SHINFELD, P.E. PLLC1305205/03/2022
Building Lifecycle
All (33)Filed (3)Permit Issued (4)Signed Off (2)Violation (11)Inspection (1)Objection (8)Special Inspection (4)
03/29/2023
Violation issued (HPD, closed)
A
03/29/2023
Violation issued (HPD, closed)
B
03/29/2023
Violation issued (HPD, open)
A
07/21/2022
Signed off — Alteration
MINOR INTERIOR WORK AS PER PLAN TO ADDRESS ECB VIOLATIONS #35635066J & 35635065H. NO CHANGE TO USE, EGRESS, AND OCCUPANCY. 1:REMOVE NEWLY BUILT ILLEGAL MASSAGE ROOM. 2:CAP & REMOVE NEWLY BUILT ILLEGAL STAND UP SHOWER.
B00730236-I1
07/21/2022
Signed off — Alteration
MINOR INTERIOR WORK AS PER PLAN TO ADDRESS ECB VIOLATIONS #35635066J & 35635065H. NO CHANGE TO USE, EGRESS, AND OCCUPANCY. THIS APPLICATION IS FOR PLUMBING WORKS ONLY. GENERAL CONSTRUCTION FILED UNDER SEPARATE APPLICATION #B00730236
B00729559-I1
07/19/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/12/2022
Permit issued — Plumbing
B00729559-I1-PL
07/07/2022
Permit issued — General Construction
B00730236-I1-GC
05/09/2022
Objection raised — Scope
05/09/2022
Objection resolved — Addressed
05/09/2022
Objection raised — Other
05/09/2022
Objection resolved — Addressed
05/09/2022
Objection raised — Scope
05/09/2022
Objection resolved — Addressed
05/09/2022
Objection raised — Scope
05/09/2022
Objection resolved — Addressed
05/03/2022
Filed — Alteration
MINOR INTERIOR WORK AS PER PLAN TO ADDRESS ECB VIOLATIONS #35635066J & 35635065H. NO CHANGE TO USE, EGRESS, AND OCCUPANCY. 1:REMOVE NEWLY BUILT ILLEGAL MASSAGE ROOM. 2:CAP & REMOVE NEWLY BUILT ILLEGAL STAND UP SHOWER.
B00730236-I1
05/03/2022
Filed — Alteration
MINOR INTERIOR WORK AS PER PLAN TO ADDRESS ECB VIOLATIONS #35635066J & 35635065H. NO CHANGE TO USE, EGRESS, AND OCCUPANCY. THIS APPLICATION IS FOR PLUMBING WORKS ONLY. GENERAL CONSTRUCTION FILED UNDER SEPARATE APPLICATION #B00730236
B00729559-I1
05/03/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALLEN SHINFELD
05/03/2022
Special inspection requirement — Final
ALLEN SHINFELD
05/03/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALLEN SHINFELD
05/03/2022
Special inspection requirement — Energy Code Compliance Inspections
ALLEN SHINFELD
04/20/2022
Violation issued (ECB, closed)
Zoning
04/20/2022
Violation issued (ECB, closed)
Construction
02/10/2021
Permit issued — Plumbing
B91234978-I1-PL
08/19/2020
Permit issued — Plumbing
B00314994-I1-PL
02/28/2020
Filed — Alteration
B00314994-I1
10/09/2015
Violation issued (HPD, closed)
I
08/18/2015
Violation issued (ECB, closed)
Construction
08/07/2015
Violation issued (ECB, closed)
Construction
08/07/2015
Violation issued (ECB, closed)
Construction
05/01/2015
Violation issued (ECB, closed)
Construction
05/01/2015
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCROSSFIELD PLBG.&HTG07/12/2022
DOB NOWGeneral ConstructionSigned-offMHLIN AND PARTNERS INC07/07/2022
DOB NOWPlumbingPermit IssuedLG ELITE PLUMBING INC02/10/2021
DOB NOWPlumbingPermit IssuedLG ELITE PLUMBING INC08/19/2020
BISOTISSUEDSOUTHERN FOLGER CONTRACT08/21/2020
1 project · most recent 07/02/2020
General Wiring
FiledStatusContractorScope
07/02/2020Permit IssuedHI-RITE ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
07/19/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
05/03/2022Fire-Resistant Penetrations and JointsALLEN SHINFELDspecial
05/03/2022FinalALLEN SHINFELDprogress
05/03/2022Fire-Resistant Penetrations and JointsALLEN SHINFELDspecial
05/03/2022Energy Code Compliance InspectionsALLEN SHINFELDprogress
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch2
08/29/2026B00729559-I1Request digital key ↗
08/15/2026B00730236-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing Legalization1
09/02/2026B00314994-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
09/02/2026B00314994-I1Request digital key ↗
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
10/22/2020322001597Open ↗
08/21/2020322001597Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
02/28/2020322001597Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026B00729559-I1Open ↗
08/13/2026B00314994-I1Open ↗
08/13/2026B00730236-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/31/2026B00730236-I1Open ↗
08/24/2026B00729559-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/31/2026B00730236-I1Open ↗
08/24/2026B00729559-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
02/28/2020322001597Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/28/2020322001597Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
02/28/2020322001597Open ↗
▸Safety & Tenant Protection2
▸BISTenant Protection Plan and Notes1
02/28/2020322001597Open ↗
▸DOB NOWTenant Protection Plan1
08/13/2026B00314994-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026B00314994-I1Open ↗
08/13/2026B00730236-I1Open ↗
08/13/2026B00729559-I1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/28/2020322001597Open ↗
▸Energy Compliance4
▸BISAS-BUILT ENERGY ANALYSIS2
02/24/2021322001597Open ↗
02/23/2021322001597Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
02/23/2021322001597Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
02/28/2020322001597Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY4
02/23/2021322001597Open ↗
02/23/2021322001597Open ↗
02/23/2021322001597Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
02/26/2021322001597Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
02/23/2021322001597Open ↗
02/28/2020322001597Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
02/28/2020322001597Open ↗
▸Other Documents2
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION2
02/26/2021322001597Open ↗
02/23/2021322001597Open ↗