← Back
General warehouse
74 THROOP AVENUE
BROOKLYN · BIN 3061432
💬 Discuss this project
1998Year Built
1Stories
E1Building Class
R7AZoning
2,500 sfGross Floor Area
1Units
5 Open Violations 4 unresolved · 1 paperwork only ▸FDNY Report ↗
General warehouse · Owner of record: 76 THROOP AVE LLC · 2,500 sf lot · 1 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalPlumbingCivil
Permit Issued — active, not yet Signed-off
RoofUnder Construction36p · 2 filings · 20 docs
Floor 8Under Construction1p · 2 filings · 20 docs
Floor 7Under Construction1p · 2 filings · 20 docs
Floor 6Under Construction1p · 2 filings · 20 docs
Floor 5Under Construction1p · 2 filings · 20 docs
Floor 4Under Construction34p · 3 filings · 20 docs
Floor 3Under Construction35p · 3 filings · 20 docs
Floor 2Under Construction34p · 3 filings · 20 docs
Floor 1Under Construction41p · 3 filings · 20 docs
CellarUnder Construction1p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OWNERS REP109/26/2026
HIRSCHI GROUP303/22/2026
76 THROOP AVE LLC103/22/2026
OWNER OF 74-76 THROOP103/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC DESIGN FILE803/21/2026
NYC PERMIT SERVICES403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIRSCHI GROUP LLCGeneral Contractor1108/06/2026
YATZIV CORPGeneral Contractor303/21/2026
JOSEPH DI GIACOMOElectrical203/21/2026
TOVIA WERZBERGERElectrical103/21/2026
CORE SCAFFOLD SYSTEMS INC.General Contractor109/26/2026
PIPE SOLUTIONS ADVIS INCPlumbing105/29/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
REGIONAL TESTING CORP.394503/31/2026
BIG APPLE GROUP NY A RMA9168111/18/2025
Building Lifecycle
All (126)Filed (16)Permit Issued (12)Violation (11)Inspection (7)Objection (50)Special Inspection (30)
09/25/2026
Permit issued — Protection and Mechanical Methods
B01449446-I1-PMM
08/19/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/19/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/11/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/05/2026
Permit issued — Structural
B00743602-S2-ST
08/05/2026
Permit issued — Protection and Mechanical Methods
B00743602-S1-PMM
08/04/2026
Permit issued — Construction Fence
B01286498-S7-FN
07/24/2026
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01435563-I1
06/10/2026
Objection raised — Other
06/08/2026
Objection raised — Other
06/05/2026
Objection resolved — Resolved
06/04/2026
Objection raised — Other
05/28/2026
Permit issued — Plumbing
B01286498-S2-PL
05/15/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Filing Combined sprinkler standpipe application subsequent to primary job number B01286498-I1
B01286498-S8
05/15/2026
Permit issued — Protection and Mechanical Methods
B00743602-S1-PMM
05/13/2026
Objection resolved — Addressed
05/13/2026
Objection resolved — Addressed
05/13/2026
Objection resolved — Addressed
05/06/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/27/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Filing Combined sprinkler standpipe application subsequent to primary job number B01286498-I1
B01286498-P1
04/21/2026
Permit issued — Structural
B00743602-S2-ST
04/17/2026
Special inspection requirement — Post-installed Anchors
Paul Raymond
04/17/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Soorjbally Harilall
04/17/2026
Special inspection requirement — Concrete - Cast-In-Place
Paul Raymond
04/17/2026
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
Paul Raymond
04/17/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Paul Raymond
04/17/2026
Special inspection requirement — Subgrade Inspections
Paul Raymond
04/17/2026
Special inspection requirement — Footing and Foundation
Paul Raymond
04/17/2026
Special inspection requirement — Final
Paul Raymond
04/16/2026
Objection resolved — Resolved
04/13/2026
Objection resolved — Addressed
04/13/2026
Objection resolved — Addressed
04/10/2026
Objection raised — Other
03/31/2026
Filed — Alteration
421-A Foundation work in conjunction with NB job number 321562037
B00743602-S1
03/31/2026
Filed — Alteration
421-A Foundation work in conjunction with NB job number 321562037
B00743602-P2
03/31/2026
Filed — Alteration
421-A Foundation work in conjunction with NB job number 321562037
B00743602-S2
03/31/2026
Objection resolved — Addressed
03/30/2026
Special inspection requirement — Subgrade Inspections
Paul Raymond
03/30/2026
Special inspection requirement — Structural Steel - Details
Paul Raymond
03/30/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Paul Raymond
03/30/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Paul Raymond
03/27/2026
Special inspection requirement — Final
Paul Raymond
03/26/2026
Objection resolved — Addressed
03/19/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Soorjbally Harilall
03/19/2026
Special inspection requirement — Concrete - Cast-In-Place
Paul Raymond
03/19/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Paul Raymond
03/19/2026
Special inspection requirement — Post-installed Anchors
Paul Raymond
03/19/2026
Special inspection requirement — Subgrade Inspections
Paul Raymond
03/19/2026
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
Paul Raymond
03/19/2026
Special inspection requirement — Final
Paul Raymond
03/19/2026
Special inspection requirement — Footing and Foundation
Paul Raymond
03/18/2026
Violation issued (ECB, closed)
Construction
03/18/2026
Violation issued (ECB, closed)
Construction
03/18/2026
Violation issued (ECB, open)
Unknown
03/18/2026
Objection resolved — Addressed
03/18/2026
Objection resolved — Addressed
03/17/2026
Objection resolved — Addressed
03/12/2026
Objection resolved — Addressed
03/06/2026
Objection resolved — Addressed
03/06/2026
Objection resolved — Addressed
Latest 60 of 126 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWProtection and Mechanical MethodsPermit IssuedCORE SCAFFOLD SYSTEMS INC.09/25/2026
DOB NOWStructuralPermit IssuedHIRSCHI GROUP LLC08/05/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedHIRSCHI GROUP LLC08/05/2026
DOB NOWConstruction FencePermit IssuedHIRSCHI GROUP LLC08/04/2026
DOB NOWPlumbingPermit IssuedPIPE SOLUTIONS ADVIS INC05/28/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedHIRSCHI GROUP LLC05/15/2026
DOB NOWStructuralPermit IssuedHIRSCHI GROUP LLC04/21/2026
DOB NOWConstruction FencePermit IssuedHIRSCHI GROUP LLC01/26/2026
DOB NOWFoundationPermit IssuedHIRSCHI GROUP LLC01/02/2026
DOB NOWFoundationPermit IssuedHIRSCHI GROUP LLC10/21/2025
DOB NOWConstruction FencePermit IssuedHIRSCHI GROUP LLC10/31/2024
DOB NOWFoundationPermit IssuedYATZIV CORP06/10/2022
BIS—ISSUEDHIRSCHI GROUP LLC06/27/2025
1 project · most recent 05/15/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/15/2026Permit IssuedHIRSCHI GROUP LLCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PEFY-P30NMAU-E4 30,000 BTU · Vrf Indoor ×8
MXZ-SM120TAM-U1 120,000 BTU · Condensing Unit ×7
PEFY-P36NMAU-E4 36,000 BTU · Vrf Indoor ×7
PEFY-P48NMAU-E4 48,000 BTU · Vrf Indoor ×5
MXZ-SM72TAM-U1 72,000 BTU · Condensing Unit ×2
PEFY-P24NMAU-E4 24,000 BTU · Vrf Indoor ×1
PMFY-P12NBMU-ER5 12,000 BTU · Vrf Indoor ×1
Beacon Morris SR-A CAST IRON 6,505 BTU · Baseboard ×30
Nutone AEN110 50 CFM · Exhaust Fan ×28
Markel E3323TD-RP 175 CFM · Electric Heater ×2
Qmark MUH0381 350 CFM · Electric Heater ×1
Ventilation
Fantech DB4XLT 195 CFM · Exhaust Fan ×4
Carnes RSDB 1,306 CFM · Vav Box ×2
Greenheck AS-20-428-A15 2,814 CFM · Exhaust Fan ×1
1 project · most recent 05/15/2026
Sprinkler System
FiledStatusContractorScope
05/15/2026——Sprinkler System
3 projects · most recent 09/09/2026
General Wiring
FiledStatusContractorScope
09/09/2026Permit IssuedPOWER DIRECT ELECTRIC INCGeneral Wiring
12/19/2025Permit IssuedPOWER DIRECT ELECTRIC INCGeneral Wiring
12/17/2025Permit IssuedM.R. ELEC'L SERVICE LLCGeneral Wiring
2 projects · most recent 05/15/2026
Steel
FiledStatusContractorScope
05/15/2026Permit IssuedHIRSCHI GROUP LLCSteel
03/31/2026Permit IssuedHIRSCHI GROUP LLCSteel
3 projects · most recent 07/24/2026
Fence Sidewalk Shed
FiledStatusContractorScope
07/24/2026——Sidewalk Shed
05/15/2026Permit IssuedHIRSCHI GROUP LLCFence
06/09/2022Permit IssuedHIRSCHI GROUP LLCFence
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
08/19/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/19/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/11/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/06/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/02/2026Pass-Final PL - More than 10 Requested FloorsPassView ↗
08/06/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/30/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 47
DateRequirementInspectorRole
04/17/2026Post-installed AnchorsPaul Raymondspecial
04/17/2026Subsurface Investigations (Borings/Test Pits)Soorjbally Harilallspecial
04/17/2026Concrete - Cast-In-PlacePaul Raymondspecial
04/17/2026Subsurface Conditions – Fill Placement & In-Place DensityPaul Raymondspecial
04/17/2026Excavations - Sheeting, Shoring, and BracingPaul Raymondspecial
04/17/2026Subgrade InspectionsPaul Raymondspecial
04/17/2026Footing and FoundationPaul Raymondprogress
04/17/2026FinalPaul Raymondprogress
03/30/2026Subgrade InspectionsPaul Raymondspecial
03/30/2026Structural Steel - DetailsPaul Raymondspecial
03/30/2026Structural Stability – Alterations of existing buildingsPaul Raymondspecial
03/30/2026Structural Stability – Alterations of existing buildingsPaul Raymondspecial
03/27/2026FinalPaul Raymondprogress
03/19/2026Subsurface Investigations (Borings/Test Pits)Soorjbally Harilallspecial
03/19/2026Concrete - Cast-In-PlacePaul Raymondspecial
03/19/2026Excavations - Sheeting, Shoring, and BracingPaul Raymondspecial
03/19/2026Post-installed AnchorsPaul Raymondspecial
03/19/2026Subgrade InspectionsPaul Raymondspecial
03/19/2026Subsurface Conditions – Fill Placement & In-Place DensityPaul Raymondspecial
03/19/2026FinalPaul Raymondprogress
03/19/2026Footing and FoundationPaul Raymondprogress
01/12/2026Duct leakage testing, insulation and design—energy_progress
01/07/2026Deep Foundation Elements—special
01/06/2026Subgrade Inspections—special
01/06/2026Structural Stability – Alterations of existing buildings—special
Latest 25 of 47.
▾Documents — 77 on file (BIS + DOB NOW)
▸Plans & Drawings18
▸DOB NOWPlans/Sketch18
08/29/2026B00749302-I1Request digital key ↗
08/17/2026B00743602-S2Request digital key ↗
08/17/2026B00743602-S1Request digital key ↗
Showing 3 of 18 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/15/2026B01286498-I1Open ↗
08/15/2026B01286498-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/15/2026B01286498-I1Open ↗
08/15/2026B01286498-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026B01286498-I1Open ↗
▸Seals & Professional Certifications37
▸DOB NOWDPL-1: Design Professional Seal & Signature18
08/17/2026B00743602-I1Open ↗
08/17/2026B00743602-S2Open ↗
08/17/2026B00743602-P2Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature14
09/02/2026B00743602-I1Open ↗
09/02/2026B00743602-I1Open ↗
09/02/2026B00743602-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/02/2026B00743602-I1Open ↗
09/02/2026B00743602-I1Open ↗
08/28/2026B00743602-P2Open ↗
Showing 3 of 5 on file for this type
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/15/2026B01286498-I1Open ↗
08/15/2026B01286498-P1Open ↗
▸DOB NOWFDNY: Letter of No Objection1
08/15/2026B01286498-S3Open ↗
▸Environmental & Asbestos4
▸DOB NOWOER: Notice to Proceed3
08/17/2026B00743602-S2Open ↗
08/17/2026B00743602-I1Open ↗
08/17/2026B01286498-S2Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/17/2026B01286498-S2Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/17/2026B00743602-I1Open ↗
08/17/2026B00743602-P2Open ↗
▸DOB NOWTR4 Plot Diagram1
08/17/2026B00743602-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/17/2026B00743602-I1Open ↗
▸Other Documents6
▸DOB NOWSite Survey: Initial2
08/15/2026B01286498-I1Open ↗
08/15/2026B01286498-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/15/2026B01286498-I1Open ↗
08/15/2026B01286498-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/15/2026B01286498-I1Open ↗
08/15/2026B01286498-P1Open ↗