← Back
Primarily 2 family with 1 store or office
7401 10 AVENUE
BROOKLYN · BIN 3148503
💬 Discuss this project
1955Year Built
2Stories
S2Building Class
R5BZoning
2,400 sfGross Floor Area
3Units
Primarily 2 family with 1 store or office · 1,550 sf lot · 1.55 FAR built · Flood zone X
Locations of Work
Architecture
Floor 26p · 1 filing · 20 docs
Floor 16p · 1 filing · 20 docs
Basement6p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/18/2024$1.5M—Private party → Private party$624/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
A PLUS DESIGN INC608/06/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A PLUS DESIGN INC.1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KALE CONSTRUCTION INCGeneral Contractor407/08/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A PLUS DESIGN INC6615608/06/2025
Building Lifecycle
All (45)Filed (6)Permit Issued (3)Signed Off (3)Inspection (6)Objection (12)Special Inspection (15)
10/23/2025
Signed off — Alteration CO
MECHANICAL WORK ON BAS, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT-CO APPLICATION.
B01148926-I1
08/25/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/13/2025
Special inspection requirement — Interior lighting power
PENG LIU
08/13/2025
Special inspection requirement — Fenestration areas
PENG LIU
08/13/2025
Special inspection requirement — Air barrier - visual inspection
PENG LIU
08/13/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
PENG LIU
08/13/2025
Special inspection requirement — Maintenance information
PENG LIU
08/13/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
PENG LIU
08/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
PENG LIU
08/13/2025
Special inspection requirement — Energy Code Compliance Inspections
PENG LIU
08/13/2025
Special inspection requirement — Fire-Resistance Rated Construction
PENG LIU
08/13/2025
Special inspection requirement — Metering
PENG LIU
08/13/2025
Special inspection requirement — Fenestration air leakage
PENG LIU
08/06/2025
Filed — Alteration CO
MECHANICAL WORK ON BAS, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT-CO APPLICATION.
B01148926-P3
07/30/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/18/2025
Signed off — Alteration CO
MECHANICAL WORK ON BAS, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT-CO APPLICATION.
B01148926-S1
07/18/2025
Signed off — Alteration CO
MECHANICAL WORK ON BAS, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT-CO APPLICATION.
B01148926-S2
07/07/2025
Permit issued — Mechanical Systems
B01148926-S2-MS
06/05/2025
Filed — Alteration CO
MECHANICAL WORK ON BAS, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT-CO APPLICATION.
B01148926-S2
05/06/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/06/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
05/02/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/29/2025
Filed — Alteration CO
MECHANICAL WORK ON BAS, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT-CO APPLICATION.
B01148926-P2
04/23/2025
Filed — Alteration CO
MECHANICAL WORK ON BAS, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT-CO APPLICATION.
B01148926-P1
04/21/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
PENG LIU
04/21/2025
Special inspection requirement — Energy Code Compliance Inspections
PENG LIU
04/21/2025
Special inspection requirement — Fire-Resistance Rated Construction
PENG LIU
04/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
PENG LIU
03/11/2025
Permit issued — Plumbing
B01148926-S1-PL
03/10/2025
Permit issued — General Construction
B01148926-I1-GC
03/05/2025
Filed — Alteration CO
MECHANICAL WORK ON BAS, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT-CO APPLICATION.
B01148926-S1
02/19/2025
Objection resolved — Addressed
01/24/2025
Objection resolved — Addressed
01/24/2025
Objection resolved — Addressed
01/21/2025
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
01/13/2025
Objection resolved — Addressed
12/18/2024
Objection resolved — Addressed
12/18/2024
Objection resolved — Addressed
12/17/2024
Objection raised — Other
12/17/2024
Objection raised — Scope
12/17/2024
Objection raised — Energy
12/17/2024
Objection raised — Scope
12/17/2024
Objection raised — Scope
12/17/2024
Objection raised — Other
12/05/2024
Filed — Alteration CO
MECHANICAL WORK ON BAS, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT-CO APPLICATION.
B01148926-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offKALE CONSTRUCTION INC07/07/2025
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC03/11/2025
DOB NOWGeneral ConstructionPermit IssuedKALE CONSTRUCTION INC03/10/2025
1 project · most recent 08/06/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/06/2025Signed-offKALE CONSTRUCTION INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Gree MULTI18HP230V1EO 18,000 BTU · Vrf Outdoor ×5
4LIV12HP230V1AH 424 CFM · Fan Coil Indoor ×2
4LIV09HP230V1AH 353 CFM · Fan Coil Indoor ×1
Ventilation
Greenheck SP-B110 50 CFM · Exhaust Fan ×6
1 project · most recent 08/06/2025
Gas Water/Sanitary
FiledStatusContractorScope
08/06/2025Signed-offCATMAN PLUMBING INCGas, Water/Sanitary
1 project · most recent 03/17/2025
General Wiring
FiledStatusContractorScope
03/17/2025CompleteJ Y ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
08/25/2025Pass-Final CND-Occupancy InspectionPassView ↗
07/30/2025Pass-Final CND-Occupancy InspectionPassView ↗
05/06/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/06/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
05/02/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/21/2025Fail-Final CND-Occupancy InspectionFailView ↗
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
08/13/2025Interior lighting powerPENG LIUenergy_progress
08/13/2025Fenestration areasPENG LIUenergy_progress
08/13/2025Air barrier - visual inspectionPENG LIUenergy_progress
08/13/2025Fenestration and door U-factor and product ratingsPENG LIUenergy_progress
08/13/2025Maintenance informationPENG LIUenergy_progress
08/13/2025Structural Stability – Alterations of existing buildingsPENG LIUspecial
08/13/2025Fire-Resistant Penetrations and JointsPENG LIUspecial
08/13/2025Energy Code Compliance InspectionsPENG LIUprogress
08/13/2025Fire-Resistance Rated ConstructionPENG LIUprogress
08/13/2025MeteringPENG LIUenergy_progress
08/13/2025Fenestration air leakagePENG LIUenergy_progress
04/21/2025Structural Stability – Alterations of existing buildingsPENG LIUspecial
04/21/2025Energy Code Compliance InspectionsPENG LIUprogress
04/21/2025Fire-Resistance Rated ConstructionPENG LIUprogress
04/21/2025Fire-Resistant Penetrations and JointsPENG LIUspecial
▾Documents — 48 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/21/2026B01148926-S1Request digital key ↗
08/21/2026B01148926-I1Request digital key ↗
08/21/2026B01148926-P3Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZoning Exhibit form (1-5)3
08/13/2026B01148926-I1Open ↗
08/13/2026B01148926-P1Open ↗
08/13/2026B01148926-P3Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp3
08/13/2026B01148926-P1Open ↗
08/13/2026B01148926-I1Open ↗
08/13/2026B01148926-P3Open ↗
▸Seals & Professional Certifications21
▸DOB NOWProgress Inspector Seal & Signature11
08/25/2026B01148926-P1Open ↗
08/25/2026B01148926-P1Open ↗
08/25/2026B01148926-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/21/2026B01148926-S1Open ↗
08/21/2026B01148926-I1Open ↗
08/21/2026B01148926-P3Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/25/2026B01148926-P1Open ↗
08/25/2026B01148926-P1Open ↗
08/25/2026B01148926-I1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist3
08/13/2026B01148926-P1Open ↗
08/13/2026B01148926-I1Open ↗
08/13/2026B01148926-P3Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B01148926-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B01148926-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B01148926-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/21/2026B01148926-S1Open ↗
08/21/2026B01148926-I1Open ↗
08/21/2026B01148926-P3Open ↗
Showing 3 of 6 on file for this type
▸Other Documents3
▸DOB NOWProperty Ownership Certification3
08/21/2026B01148926-I1Open ↗
08/21/2026B01148926-P3Open ↗
08/21/2026B01148926-P1Open ↗