← Back
Two stories - detached, small or mid-size
75-19 189 STREET
QUEENS · BIN 4155105
💬 Discuss this project
1940Year Built
2Stories
A1Building Class
R2AZoning
1,196 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,300 sf lot · 0.28 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof1p · 1 filing · 6 docs
Floor 23p · 1 filing · 20 docs
Floor 12p · 1 filing · 20 docs
Cellar3p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/24/2023$995K—— → —$832/sf building
02/22/2023$700K—Private party → BSD 189 LLC$585/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AMINOV DESIGN ENGINEER, PC1502/13/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A D BUILDING SOLUTIONS3003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRIMROSE SERVICE INCGeneral Contractor704/09/2026
BT'S PLUMBING AND HEATINGPlumbing207/08/2026
JYNY CONSTRUCTION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP56161302/13/2026
Building Lifecycle
All (72)Filed (15)Permit Issued (8)Signed Off (6)Inspection (8)Objection (5)Special Inspection (30)
03/06/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-I1
02/17/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
02/17/2026
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
02/17/2026
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
02/17/2026
Special inspection requirement — Final
FAHAD FATEH
02/17/2026
Special inspection requirement — Mechanical Systems
FAHAD FATEH
02/17/2026
Special inspection requirement — Permanent certificate
FAHAD FATEH
02/17/2026
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
02/17/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
02/17/2026
Special inspection requirement — Air barrier - visual inspection
FAHAD FATEH
02/17/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
02/17/2026
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
02/17/2026
Special inspection requirement — Electric vehicle service equipment requirements
FAHAD FATEH
02/17/2026
Special inspection requirement — Fenestration areas
FAHAD FATEH
02/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
02/17/2026
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
02/17/2026
Special inspection requirement — Ventilation and air distribution system
FAHAD FATEH
02/17/2026
Special inspection requirement — Air barrier — testing
FAHAD FATEH
02/17/2026
Special inspection requirement — Interior lighting power
FAHAD FATEH
02/13/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-P8
02/13/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
02/13/2026
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
02/13/2026
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
02/13/2026
Special inspection requirement — Fenestration areas
FAHAD FATEH
02/13/2026
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
02/13/2026
Special inspection requirement — Final
FAHAD FATEH
02/13/2026
Special inspection requirement — Permanent certificate
FAHAD FATEH
02/13/2026
Special inspection requirement — Air barrier — testing
FAHAD FATEH
02/13/2026
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
02/13/2026
Special inspection requirement — Electric vehicle service equipment requirements
FAHAD FATEH
02/13/2026
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
02/13/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
12/16/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/05/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-S2
11/24/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-S4
10/14/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-S5
10/14/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-S3
10/09/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-P6
10/09/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-P7
10/08/2025
Permit issued — Plumbing
Q00920641-S2-PL
10/08/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/19/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-S1
07/21/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-P5
04/02/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/18/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
02/21/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/19/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/16/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-P3
08/16/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-P4
08/04/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-P2
08/02/2024
Permit issued — Support of Excavation
Q00920641-S3-SE
07/30/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-P1
07/18/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/12/2024
Permit issued — Structural
Q00920641-S5-ST
06/12/2024
Permit issued — Earth Work
Q00920641-S4-FO-EA
05/02/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/15/2024
Permit issued — General Construction
Q00920641-I1-GC
03/15/2024
Permit issued — General Construction
Q00920641-I1-MS
03/06/2024
Permit issued — Plumbing
Q00920641-S2-PL
03/04/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED HORIZONTAL & VERTICAL ENLARGEMENT TO AN EXISTING ONE FAMILY DWELLING ALONG WITH INTERIOR RENOVATION
Q00920641-S4
Latest 60 of 72 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offBT'S PLUMBING AND HEATING10/08/2025
DOB NOWSupport of ExcavationSigned-offPRIMROSE SERVICE INC08/02/2024
DOB NOWStructuralSigned-offPRIMROSE SERVICE INC06/12/2024
DOB NOWEarth WorkSigned-offPRIMROSE SERVICE INC06/12/2024
DOB NOWGeneral ConstructionPermit IssuedPRIMROSE SERVICE INC03/15/2024
DOB NOWGeneral ConstructionSigned-offPRIMROSE SERVICE INC03/15/2024
DOB NOWPlumbingSigned-offBT'S PLUMBING AND HEATING03/06/2024
DOB NOWConstruction FenceSigned-offJYNY CONSTRUCTION02/27/2024
1 project · most recent 02/13/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
02/13/2026Signed-offPRIMROSE SERVICE INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MODEL# MXZ-4C36NA-U 36,000 BTU · Split System ×2
Model # MXZ-2C20NA-U 20,000 BTU · Vrf Outdoor ×1
Model # MXZ-3C24NA-U 24,000 BTU · Vrf Outdoor ×1
1 project · most recent 02/13/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
02/13/2026Signed-offBT'S PLUMBING AND HEATINGGas, Storm, Water/Sanitary
1 project · most recent 03/15/2024
General Wiring
FiledStatusContractorScope
03/15/2024CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
12/16/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/08/2025Pass-Final CND-Occupancy InspectionPassView ↗
04/02/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/18/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
02/21/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/19/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/18/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/02/2024Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 94
DateRequirementInspectorRole
02/17/2026Air barrier — testing FAHAD FATEHenergy_progress
02/17/2026Air barrier - visual inspectionFAHAD FATEHenergy_progress
02/17/2026Permanent certificateFAHAD FATEHenergy_progress
02/17/2026HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
02/17/2026Insulation placement and R valuesFAHAD FATEHenergy_progress
02/17/2026Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
02/17/2026Interior lighting powerFAHAD FATEHenergy_progress
02/17/2026HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
02/17/2026Fenestration areasFAHAD FATEHenergy_progress
02/17/2026Electric vehicle service equipment requirementsFAHAD FATEHenergy_progress
02/17/2026HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
02/17/2026Ventilation and air distribution systemFAHAD FATEHenergy_progress
02/17/2026Fenestration air leakageFAHAD FATEHenergy_progress
02/17/2026Energy Code Compliance InspectionsFAHAD FATEHprogress
02/17/2026FinalFAHAD FATEHprogress
02/17/2026Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
02/17/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
02/17/2026Mechanical SystemsFAHAD FATEHspecial
02/13/2026Permanent certificateFAHAD FATEHenergy_progress
02/13/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
02/13/2026Mechanical SystemsFAHAD FATEHspecial
02/13/2026Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
02/13/2026Energy Code Compliance InspectionsFAHAD FATEHprogress
02/13/2026FinalFAHAD FATEHprogress
02/13/2026HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
Latest 25 of 94.
▾Documents — 128 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
08/24/2026Q00892034-I1Request digital key ↗
08/21/2026Q00920641-P2Request digital key ↗
08/21/2026Q00920641-P1Request digital key ↗
Showing 3 of 15 on file for this type
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION1
10/06/2023440806692Open ↗
▸BISBPP-DOT: SIDEWALK/CURB/ROAD WORK PERMITS1
10/20/2025440806692Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
10/06/2023440806692Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram5
08/21/2026Q00920641-I1Open ↗
08/21/2026Q00920641-P8Open ↗
08/21/2026Q00920641-P7Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/21/2026Q00920641-I1Open ↗
▸Seals & Professional Certifications51
▸DOB NOWProgress Inspector Seal & Signature21
09/01/2026Q00920641-S4Open ↗
08/29/2026Q00920641-P2Open ↗
08/29/2026Q00920641-P2Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature15
08/21/2026Q00920641-P2Open ↗
08/21/2026Q00920641-P1Open ↗
08/21/2026Q00920641-S5Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature13
09/01/2026Q00920641-S3Open ↗
09/01/2026Q00920641-S4Open ↗
09/01/2026Q00920641-S4Open ↗
Showing 3 of 13 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
10/06/2023440806692Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/06/2023440806692Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)4
08/21/2026Q00920641-I1Open ↗
08/21/2026Q00920641-P8Open ↗
08/21/2026Q00920641-P7Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
11/16/2023440806692Open ↗
▸Environmental & Asbestos13
▸DOB NOWDEP ACP-5: Asbestos Assessment Report13
08/21/2026Q00920641-P2Open ↗
08/21/2026Q00920641-P1Open ↗
08/21/2026Q00920641-S5Open ↗
Showing 3 of 13 on file for this type
▸Inspections & Test Reports5
▸DOB NOWSOIL REPORT2
08/21/2026Q00920641-S4Open ↗
08/21/2026Q00920641-P4Open ↗
▸BISBPP: FIELD INSPECTION1
10/20/2025440806692Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/21/2026Q00920641-S4Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/21/2026Q00920641-S4Open ↗
▸Approvals, Objections & Sign-offs1
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
10/20/2025440806692Open ↗
▸Cost, Insurance & Ownership1
▸BISBPP: ENGINEERS AFFIDAVIT1
10/20/2025440806692Open ↗
▸Filing & Intake Forms3
▸BISEFILING JOB APPLICATION COVER SHEET1
10/06/2023440806692Open ↗
▸BISADDITIONAL INFORMATION1
10/20/2025440806692Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
10/06/2023440806692Open ↗
▸Other Documents25
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
08/21/2026Q00920641-I1Open ↗
08/21/2026Q00920641-P8Open ↗
08/21/2026Q00920641-P7Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSite Survey: Initial5
08/21/2026Q00920641-I1Open ↗
08/21/2026Q00920641-P8Open ↗
08/21/2026Q00920641-P7Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProperty Ownership Certification4
08/21/2026Q00920641-I1Open ↗
08/21/2026Q00920641-P8Open ↗
08/21/2026Q00920641-P7Open ↗
Showing 3 of 4 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION3
10/20/2025440806692Open ↗
10/20/2025440806692Open ↗
10/06/2023440806692Open ↗
▸DOB NOWAdjoining Owners Notification2
08/21/2026Q00920641-S4Open ↗
08/21/2026Q00920641-S3Open ↗
▸BISCURB CUT: PROVIDE EXISTING NUMBER1
11/16/2023440806692Open ↗
▸BISBPP: TOPOGRAPHIC SURVEY1
11/16/2023440806692Open ↗
▸BISBPP: FINAL AS-BUILT PHOTOGRAPHS1
10/20/2025440806692Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
11/16/2023440806692Open ↗
▸DOB NOWPlot Diagram1
08/13/2026Q00892034-I1Open ↗
▸DOB NOWFinal Survey1
08/21/2026Q00920641-I1Open ↗