Locations of Work
ArchitectureStructural
Roof2p · 1 filing · 20 docs
Floor 21p · 1 filing · 20 docs
Floor 12p · 1 filing · 20 docs
Cellar1p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/14/2016$805K—Private party → Private party$673/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
YAGUDAYEV ARCHITECTURE STUDIO P.C.410/25/2023
SAFE CONSULTING LLC410/03/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
YAGUDAYEV ARCHITECTURE STUDIO P C803/21/2026
Building Lifecycle
All (62)Filed (8)Objection (24)Special Inspection (30)
11/06/2023
Objection resolved — Addressed
10/25/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUESNT FILING FOR STRUCTURAL WORK
Q00930731-P1
10/25/2023
Special inspection requirement — HVAC-R and service water heating system controls
10/25/2023
Special inspection requirement — Air barrier — testing
10/25/2023
Special inspection requirement — Fire-Resistance Rated Construction
10/25/2023
Special inspection requirement — Final
10/25/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
10/25/2023
Special inspection requirement — Mechanical Systems
10/25/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
10/25/2023
Special inspection requirement — Energy Code Compliance Inspections
10/25/2023
Special inspection requirement — Insulation placement and R values
10/25/2023
Special inspection requirement — HVAC-R and service water heating equipment
10/25/2023
Special inspection requirement — Metering
10/25/2023
Special inspection requirement — Permanent certificate
10/25/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
10/25/2023
Special inspection requirement — Protection of exposed foundation insulation
10/25/2023
Special inspection requirement — Interior lighting power
10/25/2023
Special inspection requirement — Maintenance information
10/25/2023
Special inspection requirement — Fenestration air leakage
10/25/2023
Special inspection requirement — Fenestration areas
10/25/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
10/25/2023
Special inspection requirement — Electric vehicle service equipment requirements
10/25/2023
Special inspection requirement — Air barrier - visual inspection
10/16/2023
Objection resolved — Addressed
10/16/2023
Objection resolved — Addressed
10/16/2023
Objection resolved — Addressed
10/16/2023
Objection resolved — Addressed
10/16/2023
Objection resolved — Addressed
10/16/2023
Objection resolved — Addressed
10/16/2023
Objection resolved — Addressed
10/16/2023
Objection resolved — Addressed
10/16/2023
Objection resolved — Addressed
10/16/2023
Objection resolved — Addressed
10/16/2023
Objection resolved — Addressed
10/06/2023
Objection raised — Admin
10/06/2023
Objection raised — Structural
10/06/2023
Objection raised — Structural
10/06/2023
Objection raised — Other
10/06/2023
Objection raised — Fire_Protection
10/05/2023
Objection raised — Admin
10/05/2023
Objection raised — Structural
10/05/2023
Objection raised — Other
10/05/2023
Objection raised — Admin
10/05/2023
Objection raised — Other
10/05/2023
Objection raised — Other
10/05/2023
Objection raised — Structural
10/03/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUESNT FILING FOR STRUCTURAL WORK
Q00930731-S1
10/03/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUESNT FILING FOR STRUCTURAL WORK
Q00930731-I1
10/03/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUESNT FILING FOR STRUCTURAL WORK
Q00930731-S4
10/03/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUESNT FILING FOR STRUCTURAL WORK
Q00930731-S5
10/03/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUESNT FILING FOR STRUCTURAL WORK
Q00930731-S6
10/03/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUESNT FILING FOR STRUCTURAL WORK
Q00930731-S3
10/03/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUESNT FILING FOR STRUCTURAL WORK
Q00930731-S2
10/03/2023
Special inspection requirement — Subgrade Inspections
10/03/2023
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
10/03/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
10/03/2023
Special inspection requirement — Subgrade Inspections
10/03/2023
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
10/03/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
10/03/2023
Special inspection requirement — Subgrade Inspections
Latest 60 of 62 events.
Nothing on file for this building.
1 project · most recent 10/25/2023
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
10/25/2023——Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-4C36NA 36,000 BTU · Condensing Unit ×8
1 project · most recent 10/25/2023
Gas Storm Water/Sanitary
FiledStatusContractorScope
10/25/2023——Gas, Storm, Water/Sanitary
1 project · most recent 10/25/2023
Steel Concrete
FiledStatusContractorScope
10/25/2023——Steel, Concrete
1 project · most recent 10/25/2023
Fence
FiledStatusContractorScope
10/25/2023——Fence
▾Special Inspection Requirements (DOB NOW) — 46
DateRequirementInspectorRole
10/25/2023HVAC-R and service water heating system controls—energy_progress
10/25/2023Air barrier — testing —energy_progress
10/25/2023Fire-Resistance Rated Construction—progress
10/25/2023Final—progress
10/25/2023Fire-Resistant Penetrations and Joints—special
10/25/2023Mechanical Systems—special
10/25/2023Structural Stability – Alterations of existing buildings—special
10/25/2023Energy Code Compliance Inspections—progress
10/25/2023Insulation placement and R values—energy_progress
10/25/2023HVAC-R and service water heating equipment—energy_progress
10/25/2023Metering—energy_progress
10/25/2023Permanent certificate—energy_progress
10/25/2023HVAC-R and service water piping design and insulation—energy_progress
10/25/2023Protection of exposed foundation insulation—energy_progress
10/25/2023Interior lighting power—energy_progress
10/25/2023Maintenance information—energy_progress
10/25/2023Fenestration air leakage—energy_progress
10/25/2023Fenestration areas—energy_progress
10/25/2023Fenestration and door U-factor and product ratings—energy_progress
10/25/2023Electric vehicle service equipment requirements—energy_progress
10/25/2023Air barrier - visual inspection—energy_progress
10/03/2023Subgrade Inspections—special
10/03/2023Subsurface Conditions – Fill Placement & In-Place Density—special
10/03/2023Structural Stability – Alterations of existing buildings—special
10/03/2023Subgrade Inspections—special
Latest 25 of 46.
▾Documents — 46 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/24/2026Q00930731-I1Request digital key ↗
08/24/2026Q00930731-P1Request digital key ↗
08/24/2026Q00930731-S6Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits2
▸BISBPP-5 - Authorization to the Department of Transportation1
10/07/2023440806629Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
10/07/2023440806629Open ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q00930731-P1Open ↗
08/13/2026Q00930731-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00930731-I1Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/24/2026Q00930731-P1Open ↗
08/24/2026Q00930731-S6Open ↗
08/24/2026Q00930731-S5Open ↗
Showing 3 of 8 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
10/07/2023440806629Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/07/2023440806629Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026Q00930731-P1Open ↗
08/13/2026Q00930731-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/24/2026Q00930731-P1Open ↗
08/24/2026Q00930731-S6Open ↗
08/24/2026Q00930731-S5Open ↗
Showing 3 of 8 on file for this type
▸Inspections & Test Reports5
▸DOB NOWGeotechnical Report (BC 1803.6)3
08/13/2026Q00930731-S5Open ↗
08/13/2026Q00930731-S3Open ↗
08/13/2026Q00930731-S4Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q00930731-S5Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00930731-S5Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
10/07/2023440806629Open ↗
▸Other Documents7
▸DOB NOWProperty Ownership Certification2
08/24/2026Q00930731-I1Open ↗
08/24/2026Q00930731-P1Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026Q00930731-P1Open ↗
08/13/2026Q00930731-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q00930731-P1Open ↗
08/13/2026Q00930731-I1Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
10/07/2023440806629Open ↗