DOB12/05/2021DUE TO VEHICLE STRIKING THE SIDEWALK SHED WITHOUT A SECTION APPROXIMAT ELY 6'X10' COLLAPSED ONTO PEDESTRIAN WALKWAY
DOB09/03/2019FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019
DOB04/05/2019VIOLATION ISSUED TO ELEVATOR - FAILURE TO FILE CATEGORY 1 2017 INSPECTION/TEST
DOB03/21/2019V-DOB VIOLATION - ACTIVE
DOB03/15/2018V-DOB VIOLATION - ACTIVE
DOB09/15/2017VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST
DOB01/03/2017VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
DOB11/14/2016VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
DOB03/02/2016V-DOB VIOLATION - ACTIVE
DOB03/02/2015V-DOB VIOLATION - ACTIVE
DOB05/30/2014VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
DOB05/30/2014VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
DOB03/31/2008V-DOB VIOLATION - ACTIVE
DOB11/01/2006V-DOB VIOLATION - ACTIVE
DOB01/13/1997V-DOB VIOLATION - ACTIVE
DOB05/03/1991DEVICE #1F832
DOB05/03/1991DEVICE #1P19825
DOB05/03/1991DEVICE #1P19826
DOB05/03/1991DEVICE #1P19827
ECB07/09/2025EXPIRED SIDEWALK SHED PERMIT. AS NOTED: AT THE TIME OF MY INSPECTION IOBSERVED THAT SIDEWALK SHED PERMIT WAS EXPIRED. REMEDY: RENEW PERMIT.Nothing owed — awaiting certificate of correction
ECB06/02/2025TEMPORARY CONSTRUCTION EQUIPMENT ON SITE: EXPIRED PERMIT. AS NOTED: PIPE SCAFFOLD PERMIT WAS EXPIRED AT THE TIME OF MY INSPECRION. REMEDY: RENEW PERMIT.Nothing owed — awaiting certificate of correction
ECB05/23/2024MISCELLANEOUS VIOLATIONS. 3314.4.2.4. NO RIGGER OR RIGGER FOREMAN PRESENT ON SITE. AT TIME OF INSPECTION OF AN ACTIVE JOB SITE, OBSEREVED SUSPENDED SCAFFOLD IN USE WITH NO RIGGING FOREMAN OR THE SPECIAL RIGGERNothing owed — awaiting certificate of correction
ECB01/16/2024FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B AND 9B REPORT INDICATING CORRECTION OF UNSAFE DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #900374. REMEDY: FILE ACCEPTABLE REPORT.Nothing owed — awaiting certificate of correction
ECB11/15/2019SEC. 27-929.1 A.C.27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS& FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BLDGNothing owed — awaiting certificate of correction
ECB01/27/2010FAILURE TO FILE AN ARCHITECT/ENGINEER REPORT CERTIFYING EXIT/DIRECTIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER SOURCE/STORAGE BATTERY EQUIPMENT.REM:FILE ARCHITECT/ENGINEER REPORTNothing owed — awaiting certificate of correction
ECB09/25/2008FAILURE TO FILE AFFIDAVITS AND OR COMPLY W/ OTHER REQUIREMENTS SET FORTH FOR PHOTOLUMINESCENT EXIT PATH MARKING. REMEDY: COMPLY W/ REQUIREMENTS OF REFERENCE STANDARDS RS 6-1Nothing owed — awaiting certificate of correction