← Back
Four families
75 CHAMBERS STREET
MANHATTAN · BIN 1001623
💬 Discuss this project
1848Year Built
6Stories
C3Building Class
C6-4AZoning
13,980 sfGross Floor Area
4Units
Rent Stabilized3 Open Violations 2 unresolved · 1 paperwork only ▸FDNY Report ↗
Four families · Owner of record: MADISON CO · 1,921 sf lot · 7.28 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 113p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MADISON COMPANY1403/22/2026
DREAMLAND CONST CORP103/22/2026
CHAMBERS COMPANY403/21/2026
75 CHAMBERS LLC203/21/2026
325 BROADWAY ASSOC203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MJ ENGINEERING & DESIGN209/12/2024
SOTIR ASSOCIATES201/08/2024
LEON SKVIRSKY PE102/04/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SOTIR ASSOCIATES203/21/2026
BUILDING BROTHERS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CT IDEAL SUPPRESSIONGeneral Contractor303/21/2026
M. INT'L ENGINEERING PLLCGeneral Contractor107/08/2026
KATAN P & H INCPlumbing107/08/2026
NATIONAL MAINTENANCEScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE2050201/08/2024
Building Lifecycle
All (66)Filed (5)Permit Issued (4)Signed Off (2)Violation (33)Inspection (8)Objection (2)Special Inspection (12)
04/29/2026
Violation issued (HPD, closed)
A
01/30/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/18/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/15/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
06/04/2025
Violation issued (HPD, closed)
A
09/13/2024
Special inspection requirement — Energy Code Compliance Inspections
09/13/2024
Special inspection requirement — Tenant Protection Plan Compliance
09/12/2024
Filed — Alteration
MECHANICAL WORK IN CONJUNCTION WITH INTERIOR RENOVATION FOR 1ST FLOOR (DELI STORE) FILED UNDER M00970488-I1. CONNECT NEW KITCHEN HOOD DUCT TO EXISTING EXHAUST DUCT UP TO THE ROOF. INSTALL EXHAUST MAKE-UP AIR. INSTALL NEW EXHUAST FAN & COMPRESSORS ON ROOF.
M00970488-P1
07/05/2024
Violation issued (ECB, open)
Unknown
07/03/2024
Signed off — Alteration
MECHANICAL WORK IN CONJUNCTION WITH INTERIOR RENOVATION FOR 1ST FLOOR (DELI STORE) FILED UNDER M00970488-I1. CONNECT NEW KITCHEN HOOD DUCT TO EXISTING EXHAUST DUCT UP TO THE ROOF. INSTALL EXHAUST MAKE-UP AIR. INSTALL NEW EXHUAST FAN & COMPRESSORS ON ROOF.
M00970488-S1
04/01/2024
Violation issued (HPD, closed)
A
03/26/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/06/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
03/01/2024
Inspection — Fail-Final House Connection
Fail
View inspection ↗
02/28/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/26/2024
Inspection — Fail-Final House Connection
Fail
View inspection ↗
02/20/2024
Permit issued — Mechanical Systems
M00970488-S1-MS
02/15/2024
Permit issued — Plumbing
M00970488-S2-PL
02/06/2024
Filed — Alteration
MECHANICAL WORK IN CONJUNCTION WITH INTERIOR RENOVATION FOR 1ST FLOOR (DELI STORE) FILED UNDER M00970488-I1. CONNECT NEW KITCHEN HOOD DUCT TO EXISTING EXHAUST DUCT UP TO THE ROOF. INSTALL EXHAUST MAKE-UP AIR. INSTALL NEW EXHUAST FAN & COMPRESSORS ON ROOF.
M00970488-S2
01/08/2024
Filed — Alteration
MECHANICAL WORK IN CONJUNCTION WITH INTERIOR RENOVATION FOR 1ST FLOOR (DELI STORE) FILED UNDER M00970488-I1. CONNECT NEW KITCHEN HOOD DUCT TO EXISTING EXHAUST DUCT UP TO THE ROOF. INSTALL EXHAUST MAKE-UP AIR. INSTALL NEW EXHUAST FAN & COMPRESSORS ON ROOF.
M00970488-S1
12/28/2023
Permit issued — General Construction
M00970488-I1-GC
12/14/2023
Objection resolved — Addressed
12/13/2023
Objection raised — Other
12/05/2023
Filed — Alteration
MECHANICAL WORK IN CONJUNCTION WITH INTERIOR RENOVATION FOR 1ST FLOOR (DELI STORE) FILED UNDER M00970488-I1. CONNECT NEW KITCHEN HOOD DUCT TO EXISTING EXHAUST DUCT UP TO THE ROOF. INSTALL EXHAUST MAKE-UP AIR. INSTALL NEW EXHUAST FAN & COMPRESSORS ON ROOF.
M00970488-I1
12/05/2023
Special inspection requirement — Tenant Protection Plan Compliance
PAUL MARINO
12/05/2023
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
12/05/2023
Special inspection requirement — HVAC-R and service water heating equipment
PAUL MARINO
12/05/2023
Special inspection requirement — Post-installed Anchors
PAUL MARINO
12/01/2023
Special inspection requirement — Final
Hany Demetry
12/01/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
PAUL MARINO
12/01/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
PAUL MARINO
12/01/2023
Special inspection requirement — Tenant Protection Plan Compliance
PAUL MARINO
12/01/2023
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
12/01/2023
Special inspection requirement — Mechanical Systems
PAUL MARINO
03/15/2023
Violation issued (HPD, closed)
A
11/02/2022
Violation issued (HPD, closed)
I
02/15/2022
Violation issued (HPD, closed)
A
03/08/2021
Signed off — Alteration
M00404109-I1
02/08/2021
Permit issued — Sign
M00404109-I1-SG
02/04/2021
Filed — Alteration
M00404109-I1
03/10/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/14/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/24/2016
Violation issued (HPD, closed)
I
02/25/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/04/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/20/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/19/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/04/2009
Violation issued (ECB, closed)
Construction
06/22/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/10/2009
Violation issued (ECB, closed)
Construction
03/18/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/21/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/23/2007
Violation issued (ECB, closed)
Cranes and Derricks
08/23/2007
Violation issued (ECB, closed)
Cranes and Derricks
08/25/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/01/2005
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/10/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/13/2003
Violation issued (ECB, closed)
Boilers
06/04/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/10/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Latest 60 of 66 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offCT IDEAL SUPPRESSION02/20/2024
DOB NOWPlumbingPermit IssuedKATAN P & H INC02/15/2024
DOB NOWGeneral ConstructionPermit IssuedM. INT'L ENGINEERING PLLC12/28/2023
DOB NOWSignSigned-offNATIONAL MAINTENANCE, INC02/08/2021
BISOTISSUEDROMANOV INC05/23/2017
BISOTISSUEDKIM & CHO CARPENTRY CORP08/29/2012
BISEQISSUEDALL-SAFE LLC09/22/2011
BISEQISSUEDH & B CONSTRUCTION NY INC06/22/2010
BISOTISSUEDARIF BASHIR04/21/2010
BISEQISSUEDPERIMETER BRIDGE & SCAFFO03/19/2010
BISOTISSUEDARIF BASHIR01/27/2010
BISEQISSUEDPERIMETER BRIDGE & SCAFFO06/18/2009
BISOTISSUEDCHAMBERS COMPANY01/27/2005
BIS—ISSUEDWING KIN CONSTRUCION INC05/25/2000
BISPLISSUEDMAINLAND PLBG & HTG INC02/09/2000
BISBLISSUEDKIN CHI PLG AND HTG COEP08/31/1999
BISPLISSUEDKIN CHI PLG AND HTG COEP08/25/1999
BISPLISSUEDMAINLAND PLBG & HTG INC01/25/1999
BIS—ISSUEDWING KIN CONSTRUCION INC01/11/1999
BISPLISSUEDSTELLMAR PLBG & MECH.CORP03/20/1995
BIS—ISSUEDRICHTER & RATNER CONTRACTING COR06/15/1994
1 project · most recent 09/12/2024
Associated Ducts and Piping Heating and Air Conditioning Systems Refrigeration Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/12/2024Signed-offCT IDEAL SUPPRESSIONAssociated Ducts and Piping, Heating and Air Conditioning Systems, Refrigeration Systems, Ventilation Systems
Heat / Cool
Daikin DZ14XA0903 93,000 BTU · Heat Pump Outdoor ×2
Ventilation
Dayton 5DVP8 1,816 CFM · Kitchen Exhaust ×1
Greenheck BSQ-240 2,400 CFM · Makeup Air ×1
Refrigeration
Copeland XFAM 030Z TFC 081 45,000 BTU · Refrigeration Unit ×2
Ducts & Piping
Greenheck N/A Ductwork ×1
1 project · most recent 09/12/2024
Gas Water/Sanitary
FiledStatusContractorScope
09/12/2024Permit IssuedKATAN P & H INCGas, Water/Sanitary
1 project · most recent 08/19/2024
General Wiring
FiledStatusContractorScope
08/19/2024Permit IssuedVERE ELECTRIC CORP.General Wiring
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
01/30/2026Pass-Final CND-Occupancy InspectionPassView ↗
12/18/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/15/2025Fail-Final General Construction Non-Directive 14FailView ↗
03/26/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/06/2024Pass-Final PL - UndergroundPassView ↗
03/01/2024Fail-Final House ConnectionFailView ↗
02/28/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/26/2024Fail-Final House ConnectionFailView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
09/13/2024Energy Code Compliance Inspections—progress
09/13/2024Tenant Protection Plan Compliance—special
12/05/2023Tenant Protection Plan CompliancePAUL MARINOspecial
12/05/2023Energy Code Compliance InspectionsPAUL MARINOprogress
12/05/2023HVAC-R and service water heating equipmentPAUL MARINOenergy_progress
12/05/2023Post-installed AnchorsPAUL MARINOspecial
12/01/2023FinalHany Demetryprogress
12/01/2023Fire-Resistant Penetrations and JointsPAUL MARINOspecial
12/01/2023Structural Stability – Alterations of existing buildingsPAUL MARINOspecial
12/01/2023Tenant Protection Plan CompliancePAUL MARINOspecial
12/01/2023Energy Code Compliance InspectionsPAUL MARINOprogress
12/01/2023Mechanical SystemsPAUL MARINOspecial
▾Documents — 98 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch4
08/28/2026M00970488-P1Request digital key ↗
08/28/2026M00970488-S2Request digital key ↗
08/28/2026M00970488-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Sign1
09/04/2026M00404109-I1Request digital key ↗
▸Applications & Permits18
▸BISWORK PERMIT APPLICATION7
05/23/2017140644462Open ↗
05/17/2017140644462Open ↗
08/30/2012121346418Open ↗
Showing 3 of 7 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION6
05/17/2017140644462Open ↗
10/06/2010120489275Open ↗
06/23/2010120389828Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWLPC Approval/Permit5
08/13/2026M00970488-I1Open ↗
08/13/2026M00970488-S1Open ↗
08/13/2026M00970488-S2Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications35
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION11
06/21/2017140644462Open ↗
01/02/2013120489275Open ↗
10/06/2010120489275Open ↗
Showing 3 of 11 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM7
10/06/2010120489275Open ↗
06/23/2010120389828Open ↗
04/06/2010120238689Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
09/04/2026M00404109-I1Open ↗
08/28/2026M00970488-S2Open ↗
08/28/2026M00970488-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/31/2026M00970488-I1Open ↗
08/31/2026M00970488-I1Open ↗
08/27/2026M00970488-S1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
10/06/2010120489275Open ↗
01/06/2010120238689Open ↗
06/18/2009120067952Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/31/2026M00970488-I1Open ↗
08/27/2026M00970488-S1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
05/17/2017140644462Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
05/17/2017140644462Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
05/17/2017140644462Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
01/06/2010120238689Open ↗
▸DOB NOWTenant Protection Plan1
08/13/2026M00404109-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/28/2026M00970488-P1Open ↗
08/28/2026M00970488-S2Open ↗
08/28/2026M00970488-S1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER3
10/06/2010120489275Open ↗
04/06/2010120238689Open ↗
06/18/2009120067952Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
01/06/2010120238689Open ↗
▸Energy Compliance3
▸BISTR8: Energy Code Progress Inspections1
12/04/2012121346418Open ↗
▸BISEN2 - As Built Energy Analysis1
12/04/2012121346418Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026M00970488-S1Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
05/23/2017140644462Open ↗
05/17/2017140644462Open ↗
▸Approvals, Objections & Sign-offs12
▸BISLANDMARKS APPROVAL4
06/21/2017140644462Open ↗
05/17/2017140644462Open ↗
12/04/2012121346418Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
10/06/2010120489275Open ↗
06/23/2010120389828Open ↗
01/06/2010120238689Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
06/21/2017140644462Open ↗
01/02/2013120489275Open ↗
12/04/2012121346418Open ↗
Showing 3 of 4 on file for this type
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
06/21/2017140644462Open ↗
05/17/2017140644462Open ↗
11/30/2010120238689Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms6
▸BISEFILING COVER SHEET4
10/06/2010120489275Open ↗
06/23/2010120389828Open ↗
01/06/2010120238689Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION1
06/18/2009120067952Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
05/17/2017140644462Open ↗
▸Other Documents2
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
11/30/2010120238689Open ↗
11/30/2010120238689Open ↗