← Back
Elevator cooperative
75 HENRY STREET
BROOKLYN · BIN 3326018
💬 Discuss this project
1967Year Built
33Stories
D4Building Class
R8Zoning
593,599 sfGross Floor Area
370Units
LL97 CoveredRent Stabilized3 Open Violations 2 unresolved · 1 paperwork only ▸FDNY Report ↗
Elevator cooperative · Owner of record: WHITMAN OWNERS CORP · 139,721 sf lot · 4.25 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction21p · 1 filing · 18 docs
Floor 2Under Construction14p · 1 filing · 18 docs
Floor 1Under Construction14p · 1 filing · 18 docs
CellarUnder Construction22p · 1 filing · 18 docs
1 job · most recent 08/11/2025
Gas Water/Sanitary
FiledStatusContractorScope
08/11/2025Permit IssuedJOHN'S PLUMBING & HEATINGGas, Water/Sanitary
Building Lifecycle
All (15)Filed (4)Permit Issued (6)Inspection (5)
09/21/2026
Permit issued — Plumbing
B00882726-S2-PL
01/23/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/23/2025
Permit issued — Plumbing
B00882726-S2-PL
08/11/2025
Filed — Alteration
NEW SANITARY/VENT BRANCH PIPING AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00882726-P1
01/02/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/02/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/30/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/23/2024
Permit issued — Plumbing
B00882726-S2-PL
12/22/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/11/2023
Permit issued — Plumbing
B00882726-S2-PL
08/30/2023
Permit issued — Mechanical Systems
B00882726-S1-MS
08/30/2023
Permit issued — General Construction
B00882726-I1-GC
08/14/2023
Filed — Alteration
NEW SANITARY/VENT BRANCH PIPING AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00882726-S2
08/02/2023
Filed — Alteration
NEW SANITARY/VENT BRANCH PIPING AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00882726-S1
06/30/2023
Filed — Alteration
NEW SANITARY/VENT BRANCH PIPING AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00882726-I1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WHITMAN OWNER1309/22/2026
GUMLEY HAFT103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
E4P CONSULTING ENGINEERING PLLC308/11/2025
LETA ARCHITECTURE PLLC106/30/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CONSTRUCTION PERMIT SERVICES803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JOHN'S PLBG & HTG, INCPlumbing409/22/2026
L.V. REMODELING LLCGeneral Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616208/02/2023
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedJOHN'S PLBG & HTG, INC09/21/2026
DOB NOWPlumbingPermit IssuedJOHN'S PLUMBING & HEATING09/23/2025
DOB NOWPlumbingPermit IssuedJOHN'S PLUMBING & HEATING09/23/2024
DOB NOWPlumbingPermit IssuedJOHN'S PLUMBING & HEATING10/11/2023
DOB NOWMechanical SystemsPermit IssuedL.V. REMODELING LLC08/30/2023
DOB NOWGeneral ConstructionPermit IssuedL.V. REMODELING LLC08/30/2023
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
01/23/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/02/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/02/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/30/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/22/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
07/05/2023HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
07/05/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
07/05/2023Duct leakage testing, insulation and designFAHAD FATEHenergy_progress
07/05/2023HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
07/05/2023Maintenance informationFAHAD FATEHenergy_progress
07/05/2023Shutoff dampersFAHAD FATEHenergy_progress
07/05/2023HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
05/31/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
05/31/2023FinalFAHAD FATEHprogress
05/31/2023FinalFAHAD FATEHprogress
05/31/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
05/31/2023Interior lighting powerFAHAD FATEHenergy_progress
05/31/2023Fenestration air leakageFAHAD FATEHenergy_progress
05/31/2023Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
05/31/2023Mechanical SystemsFAHAD FATEHspecial
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026B00882726-S2Request digital key ↗
08/27/2026B00882726-S1Request digital key ↗
08/15/2026B00882726-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026B00882726-S2Open ↗
08/27/2026B00882726-P1Open ↗
08/27/2026B00882726-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/31/2026B00882726-I1Open ↗
08/31/2026B00882726-I1Open ↗
08/23/2026B00882726-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/31/2026B00882726-I1Open ↗
08/23/2026B00882726-S1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/27/2026B00882726-S2Open ↗
08/27/2026B00882726-S1Open ↗
08/15/2026B00882726-P1Open ↗
Showing 3 of 4 on file for this type