← Back
STATEN ISLAND
75 WOODLAND AVENUE
STATEN ISLAND · Great Kills-Eltingville · BIN 5176306
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
0 Open ViolationsFDNY Report ↗
Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Floor 242p · 2 filings · 20 docs
Floor 151p · 2 filings · 20 docs
Cellar43p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
JM TRINITY HOLDINGS2107/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JAEYOUNG JANG112/10/2025
C&P DESIGN CONSULTANTS705/12/2025
STANLEY M. KREBUSHEVSKI, R.A.111/06/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MODERN BUILDING CONSULTANT103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BEYER CONSTRUCTION CORPGeneral Contractor407/08/2026
PREMIER PL,HTG & MECH INCPlumbing207/08/2026
K.M.D MECHANICAL 1443 LLCFire Protection107/08/2026
JZ CONSTRUCTION GROUP INCGeneral Contractor104/09/2026
QUALITY PLUMBING, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
C&P DESIGN CONSULTANT8472705/12/2025
SRA PLANNING & EXPEDITING5677304/09/2025
Building Lifecycle
All (60)Filed (9)Permit Issued (8)Signed Off (5)Violation (5)Inspection (14)Objection (8)Special Inspection (11)
03/24/2026
Signed off — Alteration
S01331457-I1
03/16/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
02/09/2026
Permit issued — General Construction
S01331457-I1-GC
12/10/2025
Filed — Alteration
S01331457-I1
12/05/2025
Violation issued (ECB, closed)
Construction
12/05/2025
Violation issued (ECB, closed)
Construction
05/30/2025
Signed off — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING.2)INSTALLATION OF EXHAUST AND ERV SYSTEMS FOR VENTILATION OF EACH RESIDENCE.
S00955164-S2
05/19/2025
Signed off — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING.2)INSTALLATION OF EXHAUST AND ERV SYSTEMS FOR VENTILATION OF EACH RESIDENCE.
S00955164-S1
05/12/2025
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING.2)INSTALLATION OF EXHAUST AND ERV SYSTEMS FOR VENTILATION OF EACH RESIDENCE.
S00955164-P2
05/09/2025
Signed off — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING.2)INSTALLATION OF EXHAUST AND ERV SYSTEMS FOR VENTILATION OF EACH RESIDENCE.
S00955164-S3
05/02/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
04/30/2025
Signed off — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING.2)INSTALLATION OF EXHAUST AND ERV SYSTEMS FOR VENTILATION OF EACH RESIDENCE.
S00955164-S4
04/29/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/29/2025
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
04/09/2025
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING.2)INSTALLATION OF EXHAUST AND ERV SYSTEMS FOR VENTILATION OF EACH RESIDENCE.
S00955164-P3
04/09/2025
Permit issued — Mechanical Systems
S00955164-S2-MS
04/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stanislav Pilipenko
04/09/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Stanislav Pilipenko
04/09/2025
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
WILLIAM MONTAGUE
04/09/2025
Special inspection requirement — Energy Code Compliance Inspections
Stanislav Pilipenko
04/09/2025
Special inspection requirement — Maintenance information
Stanislav Pilipenko
04/09/2025
Special inspection requirement — HVAC-R and service water heating system controls
Stanislav Pilipenko
04/09/2025
Special inspection requirement — HVAC-R and service water heating equipment
Stanislav Pilipenko
04/09/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Stanislav Pilipenko
04/09/2025
Special inspection requirement — Permanent certificate
Stanislav Pilipenko
03/14/2025
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
03/02/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/28/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/27/2025
Permit issued — Sprinklers
S00955164-S3-PL
02/24/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/18/2025
Permit issued — Curb Cut
S00955164-S4-CC
02/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stanislav Pilipenko
02/18/2025
Special inspection requirement — Sprinkler Systems
Stanislav Pilipenko
02/17/2025
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING.2)INSTALLATION OF EXHAUST AND ERV SYSTEMS FOR VENTILATION OF EACH RESIDENCE.
S00955164-P1
12/05/2024
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING.2)INSTALLATION OF EXHAUST AND ERV SYSTEMS FOR VENTILATION OF EACH RESIDENCE.
S00955164-S2
11/20/2024
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
11/18/2024
Violation issued (ECB, closed)
Construction
11/14/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
11/13/2024
Violation issued (ECB, closed)
Construction
11/01/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/18/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/18/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/04/2024
Permit issued — Sprinklers
S00955164-S3-EW-SP
09/17/2024
Violation issued (ECB, closed)
Construction
08/14/2024
Permit issued — Plumbing
S34953927-S1-PL
08/01/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/18/2024
Permit issued — Plumbing
S00955164-S1-PL
06/20/2024
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING.2)INSTALLATION OF EXHAUST AND ERV SYSTEMS FOR VENTILATION OF EACH RESIDENCE.
S00955164-S1
06/20/2024
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING.2)INSTALLATION OF EXHAUST AND ERV SYSTEMS FOR VENTILATION OF EACH RESIDENCE.
S00955164-S4
06/18/2024
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING.2)INSTALLATION OF EXHAUST AND ERV SYSTEMS FOR VENTILATION OF EACH RESIDENCE.
S00955164-S3
05/29/2024
Permit issued — Structural
S00955164-I1-GC-CX
03/04/2024
Objection resolved — Addressed
02/12/2024
Objection resolved — Addressed
02/12/2024
Objection resolved — Addressed
02/12/2024
Objection resolved — Addressed
11/30/2023
Objection raised — Other
11/30/2023
Objection raised — Scope
11/30/2023
Objection raised — Other
11/30/2023
Objection raised — Zoning
11/06/2023
Filed — New Building
1)INSTALLATION OF SPLIT-SYSTEM DX AC UNITS FOR COOLING AND COMBI-BOILER WITH FIN-TUBE RADIATORS FOR HEATING.2)INSTALLATION OF EXHAUST AND ERV SYSTEMS FOR VENTILATION OF EACH RESIDENCE.
S00955164-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offJZ CONSTRUCTION GROUP INC02/09/2026
DOB NOWMechanical SystemsSigned-offBEYER CONSTRUCTION04/09/2025
DOB NOWSprinklersSigned-offPREMIER PL,HTG & MECH INC02/27/2025
DOB NOWCurb CutSigned-offBEYER CONSTRUCTION02/18/2025
DOB NOWSprinklersSigned-offK.M.D MECHANICAL 1443 LLC10/04/2024
DOB NOWPlumbingSigned-offQUALITY PLUMBING, INC08/14/2024
DOB NOWPlumbingSigned-offPREMIER PL,HTG & MECH INC07/18/2024
DOB NOWStructuralPermit IssuedBEYER CONSTRUCTION05/29/2024
1 project · most recent 05/12/2025
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/12/2025Signed-offBEYER CONSTRUCTION CORPAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Runtru AHU: A4AH6V48A1C30AA - CU: A4AC3042D1000AA 41,000 BTU · Split System ×1
AHU: A4AH6V48A1D30AA - CU: A4AC3048B1000BA 46,000 BTU · Split System ×1
Heating
Navien NCB-240/110H 100,000 BTU · Boiler ×1
Ventilation
Fantech HERO 150H-EC 195 CFM · Erv ×1
1 project · most recent 05/12/2025
Sprinkler System
FiledStatusContractorScope
05/12/2025Signed-offK.M.D MECHANICAL 1443 LLCSprinkler System
1 project · most recent 05/12/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
05/12/2025Signed-offPREMIER PL,HTG & MECH INCGas, Storm, Water/Sanitary
1 project · most recent 10/29/2024
General Wiring
FiledStatusContractorScope
10/29/2024CompleteRIDGE ELECTRIC CORP.General Wiring
1 project · most recent 05/12/2025
Wood
FiledStatusContractorScope
05/12/2025Signed-offBEYER CONSTRUCTION CORPWood
▾Field Inspections (DOB CAP) — 14
DateTypeResultReport
03/16/2026Pass-Final General Construction Non-Directive 14PassView ↗
05/02/2025Fail-Final General Construction Non-Directive 14FailView ↗
04/29/2025Pass-Final CND-Occupancy InspectionPassView ↗
04/29/2025Pass-Final Curb Cut Non-Directive 14PassView ↗
03/14/2025Pass-Final PL - Up to 9 Requested FloorsPassView ↗
03/02/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/28/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/24/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/20/2024Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
11/14/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
11/01/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/18/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/18/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/01/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
04/09/2025Fire-Resistant Penetrations and JointsStanislav Pilipenkospecial
04/09/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationStanislav Pilipenkospecial
04/09/2025Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesWILLIAM MONTAGUEspecial
04/09/2025Energy Code Compliance InspectionsStanislav Pilipenkoprogress
04/09/2025Maintenance informationStanislav Pilipenkoenergy_progress
04/09/2025HVAC-R and service water heating system controlsStanislav Pilipenkoenergy_progress
04/09/2025HVAC-R and service water heating equipmentStanislav Pilipenkoenergy_progress
04/09/2025HVAC-R and service water piping design and insulationStanislav Pilipenkoenergy_progress
04/09/2025Permanent certificateStanislav Pilipenkoenergy_progress
02/18/2025Fire-Resistant Penetrations and JointsStanislav Pilipenkospecial
02/18/2025Sprinkler SystemsStanislav Pilipenkospecial
▾Documents — 47 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/20/2026S00955164-P3Request digital key ↗
08/20/2026S00955164-P2Request digital key ↗
08/20/2026S00955164-P1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits2
▸BISBPP-5 - Authorization to the Department of Transportation1
11/17/2023540260732Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
11/02/2023540260732Open ↗
▸Zoning, Tax Lot & Property Records4
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
11/17/2023540260732Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026S00955164-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S00955164-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026S00955164-I1Open ↗
▸Seals & Professional Certifications16
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/20/2026S00955164-P2Open ↗
08/20/2026S00955164-P1Open ↗
08/20/2026S00955164-S4Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026S00955164-S3Open ↗
09/01/2026S00955164-P3Open ↗
09/01/2026S00955164-P3Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026S00955164-P3Open ↗
09/01/2026S00955164-P3Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
11/02/2023540260732Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/02/2023540260732Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026S00955164-I1Open ↗
▸Safety & Tenant Protection4
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026S00955164-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026S00955164-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026S00955164-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026S00955164-I1Open ↗
▸Inspections & Test Reports3
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
11/17/2023540260732Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S00955164-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026S00955164-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
11/17/2023540260732Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
11/02/2023540260732Open ↗
▸Other Documents6
▸BISBPP - DOT Builders Pavement Unit Waiver Request Form1
11/17/2023540260732Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
11/17/2023540260732Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026S00955164-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/20/2026S00955164-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026S00955164-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026S00955164-I1Open ↗