← Back
Two family brick
7503 6 AVENUE
BROOKLYN · BIN 3148886
💬 Discuss this project
1930Year Built
2Stories
B1Building Class
R4-1Zoning
2,446 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family brick · Owner of record: WANG JIA 1 LLC · 3,313 sf lot · 0.74 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WANG JIA 11607/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/29/2024$1.7M—Private party → WANG JIA 1 LLC$678/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
A PLUS DESIGN INC506/30/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A PLUS DESIGN INC.1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JZ CONSTRUCTION GROUP INCGeneral Contractor407/08/2026
ERIC & NG ELEC'L, INC.Electrical103/22/2026
PREMIER FLOW PLBG AND HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A PLUS DESIGN INC6615506/30/2025
Building Lifecycle
All (40)Filed (5)Permit Issued (3)Signed Off (2)Violation (1)Inspection (5)Special Inspection (24)
08/18/2025
Signed off — Alteration
REMOVE & ERECT PARTIAL PARTITION WALL AND INTERIOR RENOVATION ON CEL, 1ST, & 2ND FLOOR. NO CHANGE IN USE GROUP, EGRESS AND OCCUPANCY. (TOTAL: EXISTING TWO FAMILY DWELLING UNITS UNDER CO# 15758/1922.)
B01142760-I1
08/18/2025
Signed off — Alteration
REMOVE & ERECT PARTIAL PARTITION WALL AND INTERIOR RENOVATION ON CEL, 1ST, & 2ND FLOOR. NO CHANGE IN USE GROUP, EGRESS AND OCCUPANCY. (TOTAL: EXISTING TWO FAMILY DWELLING UNITS UNDER CO# 15758/1922.)
B01142760-S1
06/30/2025
Filed — Alteration
REMOVE & ERECT PARTIAL PARTITION WALL AND INTERIOR RENOVATION ON CEL, 1ST, & 2ND FLOOR. NO CHANGE IN USE GROUP, EGRESS AND OCCUPANCY. (TOTAL: EXISTING TWO FAMILY DWELLING UNITS UNDER CO# 15758/1922.)
B01142760-P3
06/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
HONGTENG CHEN
06/30/2025
Special inspection requirement — Air barrier - visual inspection
HONGTENG CHEN
06/30/2025
Special inspection requirement — Interior lighting power
HONGTENG CHEN
06/30/2025
Special inspection requirement — Fire-Resistance Rated Construction
HONGTENG CHEN
06/30/2025
Special inspection requirement — Final
HONGTENG CHEN
06/30/2025
Special inspection requirement — Energy Code Compliance Inspections
HONGTENG CHEN
06/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
HONGTENG CHEN
06/30/2025
Special inspection requirement — Fire-Resistance Rated Construction
HONGTENG CHEN
06/30/2025
Special inspection requirement — Energy Code Compliance Inspections
HONGTENG CHEN
06/30/2025
Special inspection requirement — Final
HONGTENG CHEN
06/30/2025
Special inspection requirement — Air barrier - visual inspection
HONGTENG CHEN
06/30/2025
Special inspection requirement — Interior lighting power
HONGTENG CHEN
06/24/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/21/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/14/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
03/14/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/14/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/06/2025
Special inspection requirement — Maintenance information
HONGTENG CHEN
03/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
HONGTENG CHEN
03/06/2025
Special inspection requirement — Energy Code Compliance Inspections
HONGTENG CHEN
03/06/2025
Special inspection requirement — HVAC-R and service water heating system controls
HONGTENG CHEN
03/06/2025
Special inspection requirement — HVAC-R and service water heating equipment
HONGTENG CHEN
03/06/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
HONGTENG CHEN
03/05/2025
Filed — Alteration
REMOVE & ERECT PARTIAL PARTITION WALL AND INTERIOR RENOVATION ON CEL, 1ST, & 2ND FLOOR. NO CHANGE IN USE GROUP, EGRESS AND OCCUPANCY. (TOTAL: EXISTING TWO FAMILY DWELLING UNITS UNDER CO# 15758/1922.)
B01142760-P1
03/05/2025
Filed — Alteration
REMOVE & ERECT PARTIAL PARTITION WALL AND INTERIOR RENOVATION ON CEL, 1ST, & 2ND FLOOR. NO CHANGE IN USE GROUP, EGRESS AND OCCUPANCY. (TOTAL: EXISTING TWO FAMILY DWELLING UNITS UNDER CO# 15758/1922.)
B01142760-P2
03/05/2025
Special inspection requirement — HVAC-R and service water heating system controls
HONGTENG CHEN
03/05/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
HONGTENG CHEN
03/05/2025
Special inspection requirement — HVAC-R and service water heating equipment
HONGTENG CHEN
03/05/2025
Special inspection requirement — Maintenance information
HONGTENG CHEN
03/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
HONGTENG CHEN
03/04/2025
Special inspection requirement — Energy Code Compliance Inspections
HONGTENG CHEN
12/26/2024
Permit issued — General Construction
B01142760-I1-GC
12/20/2024
Permit issued — Plumbing
B01142760-S1-PL
11/27/2024
Permit issued — General Construction
B01142760-I1-GC
11/22/2024
Filed — Alteration
REMOVE & ERECT PARTIAL PARTITION WALL AND INTERIOR RENOVATION ON CEL, 1ST, & 2ND FLOOR. NO CHANGE IN USE GROUP, EGRESS AND OCCUPANCY. (TOTAL: EXISTING TWO FAMILY DWELLING UNITS UNDER CO# 15758/1922.)
B01142760-S1
11/21/2024
Filed — Alteration
REMOVE & ERECT PARTIAL PARTITION WALL AND INTERIOR RENOVATION ON CEL, 1ST, & 2ND FLOOR. NO CHANGE IN USE GROUP, EGRESS AND OCCUPANCY. (TOTAL: EXISTING TWO FAMILY DWELLING UNITS UNDER CO# 15758/1922.)
B01142760-I1
11/15/2010
Violation issued (ECB, closed)
Unknown
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offJZ CONSTRUCTION GROUP INC12/26/2024
DOB NOWPlumbingSigned-offGALICJA PLBG AND HTG.CORP12/20/2024
DOB NOWGeneral ConstructionSigned-offJZ CONSTRUCTION GROUP INC11/27/2024
2 projects · most recent 07/30/2025
General Wiring
FiledStatusContractorScope
07/30/2025CompleteERIC & NG ELEC'L, INC.General Wiring
04/17/2025CompleteERIC & NG ELEC'L, INC.3 meters, 3 new_meters
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
06/24/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/21/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/14/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/14/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/14/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
06/30/2025Fire-Resistant Penetrations and JointsHONGTENG CHENspecial
06/30/2025Air barrier - visual inspectionHONGTENG CHENenergy_progress
06/30/2025Interior lighting powerHONGTENG CHENenergy_progress
06/30/2025Fire-Resistance Rated ConstructionHONGTENG CHENprogress
06/30/2025FinalHONGTENG CHENprogress
06/30/2025Energy Code Compliance InspectionsHONGTENG CHENprogress
06/30/2025Fire-Resistant Penetrations and JointsHONGTENG CHENspecial
06/30/2025Fire-Resistance Rated ConstructionHONGTENG CHENprogress
06/30/2025Energy Code Compliance InspectionsHONGTENG CHENprogress
06/30/2025FinalHONGTENG CHENprogress
06/30/2025Air barrier - visual inspectionHONGTENG CHENenergy_progress
06/30/2025Interior lighting powerHONGTENG CHENenergy_progress
03/06/2025Maintenance informationHONGTENG CHENenergy_progress
03/06/2025Fire-Resistant Penetrations and JointsHONGTENG CHENspecial
03/06/2025Energy Code Compliance InspectionsHONGTENG CHENprogress
03/06/2025HVAC-R and service water heating system controlsHONGTENG CHENenergy_progress
03/06/2025HVAC-R and service water heating equipmentHONGTENG CHENenergy_progress
03/06/2025HVAC-R and service water piping design and insulationHONGTENG CHENenergy_progress
03/05/2025HVAC-R and service water heating system controlsHONGTENG CHENenergy_progress
03/05/2025HVAC-R and service water piping design and insulationHONGTENG CHENenergy_progress
03/05/2025HVAC-R and service water heating equipmentHONGTENG CHENenergy_progress
03/05/2025Maintenance informationHONGTENG CHENenergy_progress
03/04/2025Fire-Resistant Penetrations and JointsHONGTENG CHENspecial
03/04/2025Energy Code Compliance InspectionsHONGTENG CHENprogress
▾Documents — 39 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/22/2026B01142760-I1Request digital key ↗
08/22/2026B01142760-P3Request digital key ↗
08/22/2026B01142760-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications29
▸DOB NOWProgress Inspector Seal & Signature20
09/25/2026B01142760-S1Open ↗
09/25/2026B01142760-S1Open ↗
09/25/2026B01142760-S1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/22/2026B01142760-P2Open ↗
08/22/2026B01142760-I1Open ↗
08/22/2026B01142760-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/25/2026B01142760-S1Open ↗
09/19/2026B01142760-P1Open ↗
08/29/2026B01142760-P3Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/22/2026B01142760-P2Open ↗
08/22/2026B01142760-S1Open ↗
08/22/2026B01142760-I1Open ↗
Showing 3 of 5 on file for this type