← Back
Miscellaneous utility property
751 MILL ROAD
STATEN ISLAND · BIN 5176829
💬 Discuss this project
0Year Built
—Stories
U9Building Class
R3XZoning
0 sfGross Floor Area
0Units
5 Open Violations 0 unresolved · 5 paperwork only ▸FDNY Report ↗
Miscellaneous utility property · Owner of record: NYC DEPARTMENT OF ENVIRONMENTAL PROTECTION · 1,142,766 sf lot · 0 FAR built · Flood zone AE
Locations of Work
StructuralMechanical
Roof1p · 1 filing · 13 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYCDEP203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BROWN AND CALDWELL101/22/2025
JUSTIN C MINADEO101/20/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BROWN & CALDWELL403/21/2026
Building Lifecycle
All (39)Filed (2)Objection (10)Special Inspection (27)
10/03/2025
Objection resolved — Addressed
10/03/2025
Objection resolved — Addressed
05/12/2025
Objection raised — Fire_Protection
05/07/2025
Objection resolved — Addressed
05/07/2025
Objection resolved — Addressed
03/10/2025
Objection raised — Scope
03/10/2025
Objection raised — Scope
03/10/2025
Objection raised — Scope
03/04/2025
Objection resolved — Addressed
02/19/2025
Special inspection requirement — Exterior lighting power
02/19/2025
Special inspection requirement — Lighting controls
02/19/2025
Special inspection requirement — Interior lighting power
01/24/2025
Objection raised — Scope
01/22/2025
Filed — New Building
INSTALL 2 MAIN TRANSFORMERS, CONSTRUCT NEW SINGLE-STORY ELECTRICAL SERVICE BLDG, INSTALL ELECTRICAL MANHOLES AND UNDERGROUND DUCTBANKS, NEW SIDEWALKS AND DRIVEWAY, CONSTRUCT NEW STORMWATER MGMT INFILTRATION BASIN, AND DEMO EXISTING TRANSFORMER ENCLOSURE
S01089816-S1
01/20/2025
Filed — New Building
INSTALL 2 MAIN TRANSFORMERS, CONSTRUCT NEW SINGLE-STORY ELECTRICAL SERVICE BLDG, INSTALL ELECTRICAL MANHOLES AND UNDERGROUND DUCTBANKS, NEW SIDEWALKS AND DRIVEWAY, CONSTRUCT NEW STORMWATER MGMT INFILTRATION BASIN, AND DEMO EXISTING TRANSFORMER ENCLOSURE
S01089816-I1
10/28/2024
Special inspection requirement — Fenestration areas
10/28/2024
Special inspection requirement — Fenestration air leakage
09/25/2024
Special inspection requirement — Seismic Isolation Systems
09/25/2024
Special inspection requirement — Structural Steel - Welding
09/25/2024
Special inspection requirement — Subgrade Inspections
09/25/2024
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
09/25/2024
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
09/25/2024
Special inspection requirement — Deep Foundation Elements
09/25/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
09/25/2024
Special inspection requirement — Energy Code Compliance Inspections
09/25/2024
Special inspection requirement — Insulation placement and R values
09/25/2024
Special inspection requirement — Preliminary
09/25/2024
Special inspection requirement — Concrete - Cast-In-Place
09/25/2024
Special inspection requirement — Concrete - Precast
09/25/2024
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
09/25/2024
Special inspection requirement — Post-installed Anchors
09/25/2024
Special inspection requirement — Air barrier - visual inspection
09/25/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
09/16/2024
Special inspection requirement — Structural Steel - Details
09/16/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
09/16/2024
Special inspection requirement — Masonry
08/01/2024
Special inspection requirement — Lowest Floor Elevation
08/01/2024
Special inspection requirement — Final
08/01/2024
Special inspection requirement — Footing and Foundation
Nothing on file for this building.
1 project · most recent 01/22/2025
Air Conditioning Systems Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/22/2025——Air Conditioning Systems, Heating and Air Conditioning Systems, Ventilation Systems
Cooling
Trane 4TTA7048 49,880 BTU · Condensing Unit ×8
Heat / Cool
Trane 4TTA7048 34,100 BTU · Fan Coil Indoor ×8
Ventilation
Greenheck G-120-A 1,771 CFM · Exhaust Fan ×8
IC-24-B5-J1 6,400 CFM · Exhaust Fan ×8
1 project · most recent 01/22/2025
Steel Concrete Masonry
FiledStatusContractorScope
01/22/2025——Steel, Concrete, Masonry
1 project · most recent 01/22/2025
FiledStatusContractorScope
01/22/2025——42 panels, 18.9 kw
▾Special Inspection Requirements (DOB NOW) — 27
DateRequirementInspectorRole
02/19/2025Exterior lighting power—energy_progress
02/19/2025Lighting controls—energy_progress
02/19/2025Interior lighting power—energy_progress
10/28/2024Fenestration areas—energy_progress
10/28/2024Fenestration air leakage—energy_progress
09/25/2024Seismic Isolation Systems—special
09/25/2024Structural Steel - Welding—special
09/25/2024Subgrade Inspections—special
09/25/2024Subsurface Conditions – Fill Placement & In-Place Density—special
09/25/2024Wall Panels, Curtain Walls, and Veneers—special
09/25/2024Deep Foundation Elements—special
09/25/2024Subsurface Investigations (Borings/Test Pits)—special
09/25/2024Energy Code Compliance Inspections—progress
09/25/2024Insulation placement and R values—energy_progress
09/25/2024Preliminary—progress
09/25/2024Concrete - Cast-In-Place—special
09/25/2024Concrete - Precast—special
09/25/2024Excavations - Sheeting, Shoring, and Bracing—special
09/25/2024Post-installed Anchors—special
09/25/2024Air barrier - visual inspection—energy_progress
09/25/2024Fenestration and door U-factor and product ratings—energy_progress
09/16/2024Structural Steel - Details—special
09/16/2024Structural Stability – Alterations of existing buildings—special
09/16/2024Masonry—special
08/01/2024Lowest Floor Elevation—progress
Latest 25 of 27.
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/15/2026S01089816-I1Request digital key ↗
08/15/2026S01089816-S1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S01089816-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026S01089816-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026S01089816-I1Open ↗
08/20/2026S01089816-S1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/15/2026S01089816-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
08/13/2026S01089816-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter2
08/15/2026S01089816-I1Open ↗
08/15/2026S01089816-S1Open ↗
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)1
08/13/2026S01089816-S1Open ↗
▸Other Documents2
▸DOB NOWSite Survey: Initial1
08/13/2026S01089816-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026S01089816-I1Open ↗