← Back
Two family converted from one family
754 MADISON STREET
BROOKLYN · BIN 3045274
💬 Discuss this project
1910Year Built
2Stories
B3Building Class
R6BZoning
1,944 sfGross Floor Area
2Units
Two family converted from one family · 1,800 sf lot · 1.08 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 11p · 1 filing · 16 docs
Cellar1p · 1 filing · 16 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/09/2021$2.0M—— → —$1,016/sf building
09/21/2018$1.6M—SHABAT HOMES LLC → Private party$818/sf building
04/20/2017$600K—— → —$309/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GAMILL ENGINEERING, P.C406/17/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GAMILL ENGINEERING, PC803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PETRI PBG & HTG INCPlumbing207/08/2026
FRANCIS CAPORALEElectrical103/21/2026
MARIO CASTROElectrical103/21/2026
PETRI PLUMBING & HEATINGGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GAMILL ENGINEERING, P.C.1773406/17/2020
Building Lifecycle
All (12)Filed (4)Permit Issued (2)Signed Off (2)Special Inspection (4)
07/08/2020
Signed off — Alteration
B00316187-I1
07/08/2020
Signed off — Alteration
NEW HOT WATER HEATERS, FURNACE AND ASSOCIATED GAS PIPING. NO CHANGE IN USE, OCCUPANCY OR MEANS OF EGRESS.
B00315546-I1
06/23/2020
Permit issued — Mechanical Systems
B00316187-I1-MS
06/17/2020
Filed — Alteration
B00316187-I1
03/05/2020
Filed — Alteration
NEW HOT WATER HEATERS, FURNACE AND ASSOCIATED GAS PIPING. NO CHANGE IN USE, OCCUPANCY OR MEANS OF EGRESS.
B00315546-P2
03/04/2020
Filed — Alteration
NEW HOT WATER HEATERS, FURNACE AND ASSOCIATED GAS PIPING. NO CHANGE IN USE, OCCUPANCY OR MEANS OF EGRESS.
B00315546-P1
03/02/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
JACK GAMILL
03/02/2020
Special inspection requirement — HVAC insulation and sealing
JACK GAMILL
03/02/2020
Special inspection requirement — HVAC and service water heating equipment
JACK GAMILL
03/02/2020
Special inspection requirement — HVAC and service water heating system controls
JACK GAMILL
02/21/2020
Filed — Alteration
NEW HOT WATER HEATERS, FURNACE AND ASSOCIATED GAS PIPING. NO CHANGE IN USE, OCCUPANCY OR MEANS OF EGRESS.
B00315546-I1
02/21/2020
Permit issued — Plumbing
B00315546-I1-PL
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offPETRI PLUMBING & HEATING06/23/2020
DOB NOWPlumbingSigned-offPETRI PBG & HTG INC02/21/2020
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
03/02/2020Fire-Resistant Penetrations and JointsJACK GAMILLspecial
03/02/2020HVAC insulation and sealing JACK GAMILLenergy_progress
03/02/2020HVAC and service water heating equipment JACK GAMILLenergy_progress
03/02/2020HVAC and service water heating system controls JACK GAMILLenergy_progress
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Plumbing3
09/02/2026B00315546-I1Request digital key ↗
08/15/2026B00315546-P1Request digital key ↗
08/15/2026B00315546-P2Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/02/2026B00316187-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/13/2026B00316187-I1Open ↗
08/13/2026B00315546-I1Open ↗
08/13/2026B00315546-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/28/2026B00315546-P1Open ↗
08/28/2026B00315546-P1Open ↗
08/28/2026B00315546-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026B00315546-P1Open ↗
▸Safety & Tenant Protection4
▸DOB NOWTenant Protection Plan4
08/13/2026B00316187-I1Open ↗
08/13/2026B00315546-P2Open ↗
08/13/2026B00315546-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026B00315546-P2Open ↗
08/13/2026B00315546-P1Open ↗
08/13/2026B00315546-I1Open ↗
Showing 3 of 4 on file for this type