← Back
BuildNYC
Two family converted from one family
755 QUINCY STREET
BROOKLYN · BIN 3044387
💬 Discuss this project
1905Year Built
3Stories
B3Building Class
R6BZoning
2,856 sfGross Floor Area
2Units
Rent Stabilized0 Active ViolationsFDNY Report ↗
Two family converted from one family · 1,700 sf lot · 1.68 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof14p · 1 filing · 20 docs
Bulkhead2p · 1 filing · 20 docs
Floor 315p · 1 filing · 20 docs
Floor 214p · 1 filing · 20 docs
Floor 120p · 1 filing · 20 docs
Cellar19p · 1 filing · 20 docs
Basement1p · 1 filing · 20 docs
Sub-Basement14p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/22/2023$2.1M—LERNER002 LCC → Private party$735/sf building
03/08/2021$1.2M—Private party → LERNER002 LLC$438/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Chi F. Lau Architect811/23/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB Building Consulting1603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Siteline ConstructionGeneral Contractor303/21/2026
Siteline Constructionspecialty_contractor107/08/2026
Best Plumbing & HVACPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD Testing & Inspection S7010811/23/2021
Building Lifecycle
12/04/2024
§27-2107 ADM code owner failed to file a valid registration statement with the department as required by ADM code §27-2097 and is therefore subject…
HPD violation · closed
03/15/2022
Signed off — Alteration
PROPOSE MECHANICAL WORK INCONJUNCTION WITH ARCH AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00509680-S1
03/15/2022
Signed off — Alteration
PROPOSE MECHANICAL WORK INCONJUNCTION WITH ARCH AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00509680-I1
03/11/2022
Signed off — Alteration
PROPOSE MECHANICAL WORK INCONJUNCTION WITH ARCH AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00509680-S2
02/17/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
70 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offBest Plumbing & HVAC07/16/2021
DOB NOWGeneral ConstructionSigned-offSiteline Construction07/16/2021
DOB NOWMechanical SystemsSigned-offSiteline Construction07/16/2021
1 project · most recent 10/15/2021
General Wiring
FiledStatusContractorScope
10/15/2021CompleteJun Safety ElectricalGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/17/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/12/2021Pass-Final PL - Up to 9 Requested FloorsPassView ↗
09/28/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/28/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/16/2021Pass-Final PL - Up to 9 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 22
DateRequirementInspectorRole
09/03/2021Fire-Resistant Penetrations and Joints—special
08/26/2021Structural Stability – Alterations of existing buildingsXIUCHENG LIspecial
08/26/2021Energy Code Compliance InspectionsXIUCHENG LIprogress
08/26/2021FinalXIUCHENG LIprogress
08/26/2021Fire-Resistance Rated ConstructionXIUCHENG LIprogress
08/26/2021Exterior lighting powerXIUCHENG LIenergy_progress
08/26/2021Lighting controlsXIUCHENG LIenergy_progress
08/26/2021Fenestration and door U-factor and product ratingsXIUCHENG LIenergy_progress
08/26/2021Fenestration air leakageXIUCHENG LIenergy_progress
08/26/2021Insulation placement and R valuesXIUCHENG LIenergy_progress
08/26/2021Lighting in dwelling unitsXIUCHENG LIenergy_progress
08/26/2021Interior lighting powerXIUCHENG LIenergy_progress
08/26/2021Fenestration areasXIUCHENG LIenergy_progress
08/26/2021Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
08/26/2021Energy Code Compliance InspectionsXIUCHENG LIprogress
08/26/2021Mechanical SystemsXIUCHENG LIspecial
08/26/2021Energy Code Compliance InspectionsXIUCHENG LIprogress
08/26/2021FinalXIUCHENG LIprogress
08/26/2021HVAC-R and service water piping design and insulationXIUCHENG LIenergy_progress
08/26/2021HVAC-R and service water heating system controlsXIUCHENG LIenergy_progress
08/26/2021Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
08/26/2021HVAC-R and service water heating equipmentXIUCHENG LIenergy_progress
35 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account