| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 04/01/2026 | Permit Issued | NEW EMPIRE BUILDER CORP | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Lg LG - ARUMO36GSS5 42,000 BTU · Vrf Outdoor ×51 LG - ARUM048GSS5 54,000 BTU · Vrf Outdoor ×31 LG - ARNU363B8A4 40,600 BTU · Vrf Indoor ×6 LG - ARNU483B8A4 54,200 BTU · Vrf Indoor ×5 LG - ARUM144BTE5 162,000 BTU · Vrf Outdoor ×3 LG - ARNU283M3A4 31,500 BTU · Vrf Indoor ×2 LG - ARNU053TRD4 6,100 BTU · Vrf Indoor ×1 LG - ARNU183TQD4 21,500 BTU · Vrf Indoor ×1 LG - ARUM192BTE5 216,000 BTU · Vrf Outdoor ×1 LG-ARUM060GSS5 64,000 BTU · Vrf Outdoor ×1 ZRUM144BTE6 144,000 BTU · Vrf Outdoor ×20 ZRUM096BTE6 96,000 BTU · Vrf Outdoor ×8 ZRUM121BTE6 119,700 BTU · Vrf Outdoor ×7 ZRNU363B8AA 36,200 BTU · Vrf Indoor ×4 ZRUM168BTE6 168,000 BTU · Vrf Outdoor ×3 KNSAL241A 22,000 BTU · Vrf Indoor ×1 ZRNU483B8AA 48,100 BTU · Vrf Indoor ×1 ZRNU763B8Z6 76,400 BTU · Vrf Indoor ×1 ZRUM072BTE6 81,000 BTU · Vrf Outdoor ×1 Daikin DAIKIN - FXUQ18PAVJU 20,000 BTU · Vrf Indoor ×26 DAIKIN - RXYQ12OXATJA 135,000 BTU · Vrf Outdoor ×1 DAIKIN - RXYQ144XATJA 162,000 BTU · Vrf Outdoor ×1 DAIKIN-RXYQ72XATJA 81,000 BTU · Vrf Outdoor ×1 Ventilation Renewaire ERV-20-15H 1,830 CFM · Erv ×2 ERV-45-15L 2,160 CFM · Erv ×2 ERV-45-15H 2,730 CFM · Erv ×1 ERVe-45-15H 3,340 CFM · Erv ×1 HE10IN 600 CFM · Erv ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/21/2026 | — | — | 48 heads |
| 04/01/2026 | Permit Issued | RRP PLUMBING CORP | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/01/2026 | Permit Issued | RRP PLUMBING CORP | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/24/2026 | Permit Issued | NASH ELECTRIC SERVICES IN | — |
| 09/23/2026 | Permit Issued | Q.Y. ELECTRIC, INC | — |
| 09/23/2026 | Permit Issued | Q.Y. ELECTRIC, INC | — |
| 09/23/2026 | Permit Issued | Q.Y. ELECTRIC, INC | — |
| 09/23/2026 | Permit Issued | Q.Y. ELECTRIC, INC | — |
| 09/23/2026 | Permit Issued | Q.Y. ELECTRIC, INC | 136 meters, 136 new_meters |
| 03/03/2026 | Permit Issued | NASH ELECTRIC SERVICES IN | — |
| 09/08/2023 | Complete | HIGH QUALITY ELECTRIC OF | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/01/2026 | Permit Issued | NEW EMPIRE BUILDER CORP | Concrete |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/30/2026 | Permit Issued | MC SUPERSTRUCTURE INC | Sidewalk Shed |
| 09/12/2025 | Permit Issued | NEW EMPIRE BUILDER CORP | Fence |
| 07/20/2023 | Permit Issued | NEW EMPIRE BUILDER CORP | Fence |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/01/2026 | Permit Issued | NEW EMPIRE BUILDER CORP | Earthwork |
| Owner | Filings | Most Recent |
|---|---|---|
| LONGHORN CORP | 1 | 04/09/2026 |
| CELTIC SERVICES NYC INC | 5 | 03/22/2026 |
| NEW EMPIRE BUILDER | 2 | 03/22/2026 |
| NERE FLATBUSH MANAGEMENT LLC | 4 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| NOMAD R&D LLC | 1 | 08/13/2026 |
| ALL CITY ENGINEERING, P.C. | 6 | 07/21/2026 |
| FL&M ENGINEERING DESIGN &INSPECTION | 3 | 06/30/2026 |
| BUILDING CONSULTING ENGINEERING | 2 | 05/11/2026 |
| LOMBARDO PROFESSIONAL ENGINEERING | 1 | 04/01/2026 |
| TIMES BUILDINGS ENGINEERING SER PC | 7 | 10/01/2025 |
| MORALI ARCHITECTURE | 3 | 06/23/2025 |
| AP PROFESSIONAL ENGINEERING PLLC | 1 | 09/08/2023 |
| TIMES BUILDINGS ENGINEERING SERVICE | 1 | 07/20/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| SANDEEP KAUR | 1 | 03/21/2026 |
| ANTHONY MORALI ARCHITECT PLLC | 22 | 03/21/2026 |
| ARCHI PRO GROUP | 1 | 03/21/2026 |
| BUILDING CONSULTING ENGINEERING & A | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| NEW EMPIRE BUILDER CORP | General Contractor | 17 | 09/16/2026 |
| MC SUPERSTRUCTURE INC | General Contractor | 3 | 08/14/2026 |
| CELTIC SERVICES NYC INC | General Contractor | 3 | 03/21/2026 |
| RRP PLUMBING CORP | Fire Protection | 2 | 07/08/2026 |
| RRP PLUMBING CORP | Plumbing | 1 | 07/08/2026 |
| ROBERT MARCHISOTTO | Electrical | 1 | 03/21/2026 |
| POSITIVE LIFTING CORP | General Contractor | 1 | 04/09/2026 |
| IRVING PURCELL | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| TIMES BUILDINGS ENGINEERI | 710 | 7 | 03/27/2026 |
| BUILDING CONSULTING ENGIN | 1034 | 2 | 10/01/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Construction Fence | Permit Issued | NEW EMPIRE BUILDER CORP | 09/15/2026 |
| DOB NOW | Support of Excavation | Permit Issued | NEW EMPIRE BUILDER CORP | 08/25/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | NEW EMPIRE BUILDER CORP | 08/25/2026 |
| DOB NOW | General Construction | Permit Issued | NEW EMPIRE BUILDER CORP | 08/20/2026 |
| DOB NOW | Protection and Mechanical Methods | Permit Issued | MC SUPERSTRUCTURE INC | 08/13/2026 |
| DOB NOW | Sidewalk Shed | Permit Issued | MC SUPERSTRUCTURE INC | 08/05/2026 |
| DOB NOW | Construction Fence | Permit Issued | NEW EMPIRE BUILDER CORP | 07/31/2026 |
| DOB NOW | General Construction | Permit Issued | NEW EMPIRE BUILDER CORP | 05/06/2026 |
| DOB NOW | Structural | Permit Issued | NEW EMPIRE BUILDER CORP | 05/01/2026 |
| DOB NOW | Sidewalk Shed | Permit Issued | MC SUPERSTRUCTURE INC | 04/28/2026 |
| DOB NOW | Structural | Permit Issued | NEW EMPIRE BUILDER CORP | 04/10/2026 |
| DOB NOW | Earth Work | Permit Issued | NEW EMPIRE BUILDER CORP | 04/08/2026 |
| DOB NOW | Protection and Mechanical Methods | Permit Issued | POSITIVE LIFTING CORP | 04/02/2026 |
| DOB NOW | Structural | Permit Issued | NEW EMPIRE BUILDER CORP | 12/17/2025 |
| DOB NOW | Sprinklers | Permit Issued | RALPH W. LANDOLFI JR. | 12/11/2025 |
| DOB NOW | Sprinklers | Permit Issued | RALPH W. LANDOLFI JR. | 12/11/2025 |
| DOB NOW | Plumbing | Permit Issued | RRP PLUMBING CORP | 12/11/2025 |
| DOB NOW | Earth Work | Permit Issued | NEW EMPIRE BUILDER CORP | 09/30/2025 |
| DOB NOW | Construction Fence | Permit Issued | NEW EMPIRE BUILDER CORP | 09/15/2025 |
| DOB NOW | Construction Fence | Permit Issued | NEW EMPIRE BUILDER CORP | 08/06/2025 |
| DOB NOW | Support of Excavation | Permit Issued | NEW EMPIRE BUILDER CORP | 07/07/2025 |
| DOB NOW | Construction Fence | Permit Issued | NEW EMPIRE BUILDER CORP | 08/09/2024 |
| DOB NOW | Sidewalk Shed | Signed-off | CELTIC SERVICES NYC INC | 09/08/2023 |
| DOB NOW | Construction Fence | Permit Issued | NEW EMPIRE BUILDER CORP | 07/24/2023 |
| BIS | EQ | ISSUED | NEW EMPIRE BUILDER CORP | 08/01/2023 |
| BIS | — | ISSUED | NEW EMPIRE BUILDER CORP | 08/01/2023 |
| BIS | PL | ISSUED | ARIANA CONTRACTING INC | 09/22/2011 |
| BIS | EQ | ISSUED | ONE WAY DUCT INC | 09/14/2011 |
| BIS | OT | ISSUED | ONE WAY DUCT INC | 09/14/2011 |
| BIS | FP | ISSUED | NY BUSINESS FIRE SYSTM INC | 07/08/2005 |
| BIS | FP | ISSUED | ACTIVE FIRE EXTINGUISHER CO INC | 04/14/1998 |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/21/2026 | Duct leakage testing, insulation and design | TONY ONYEAGORO | energy_progress |
| 08/21/2026 | Maintenance information | TONY ONYEAGORO | energy_progress |
| 08/21/2026 | HVAC-R and service water heating system controls | TONY ONYEAGORO | energy_progress |
| 08/21/2026 | HVAC-R and service water piping design and insulation | TONY ONYEAGORO | energy_progress |
| 08/21/2026 | HVAC-R and service water heating equipment | TONY ONYEAGORO | energy_progress |
| 08/21/2026 | Shutoff dampers | TONY ONYEAGORO | energy_progress |
| 08/21/2026 | Final | — | progress |
| 08/21/2026 | Energy Code Compliance Inspections | — | progress |
| 08/21/2026 | Mechanical Systems | — | special |
| 08/21/2026 | Chimneys and vents | — | special |
| 08/21/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 08/21/2026 | Exhaust and Vent Systems in Plenums and Ducts | — | special |
| 07/07/2026 | Post-installed Anchors | — | special |
| 07/07/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 07/07/2026 | Sprinkler Systems | — | special |
| 05/23/2026 | Fire-Resistant Penetrations and Joints | ZHUANG MIAO | special |
| 05/23/2026 | Energy Code Compliance Inspections | ZHUANG MIAO | progress |
| 05/23/2026 | Maintenance information | TONY ONYEAGORO | energy_progress |
| 05/23/2026 | HVAC-R and service water piping design and insulation | TONY ONYEAGORO | energy_progress |
| 05/23/2026 | HVAC-R and service water heating equipment | TONY ONYEAGORO | energy_progress |
| 05/23/2026 | HVAC-R and service water heating system controls | TONY ONYEAGORO | energy_progress |
| 05/23/2026 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | ZHUANG MIAO | special |
| 05/06/2026 | Exterior lighting power | TONY ONYEAGORO | energy_progress |
| 05/06/2026 | Fenestration air leakage | TONY ONYEAGORO | energy_progress |
| 05/06/2026 | Lighting in dwelling units | TONY ONYEAGORO | energy_progress |