← Back
Three families
758 EAST 223 STREET
BRONX · Williamsbridge-Olinville · BIN 2063343
💬 Discuss this project
2022Year Built
3Stories
C0Building Class
R5Zoning
7,147 sfGross Floor Area
3Units
Rent Stabilized4 Open Violations ▸
Three families · Owner of record: NEW EAST 223 LLC · 3,371 sf lot · 2.12 FAR built · Flood zone X
Locations of Work
StructuralElectricalFire Protection
Floor 315p · 2 filings · 20 docs
Floor 217p · 2 filings · 20 docs
Floor 115p · 2 filings · 20 docs
Cellar7p · 1 filing · 9 docs
Site & exterior1p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEW EAST 223 LLC203/22/2026
NEIGHBORHOOD RESTORE HDFC103/21/2026
REALNET HOLDING103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SIDERIS KEFALAS ENGINEERS PC305/29/2024
RAS PE CONSULTING ENGINEERS309/14/2023
STEVEN KUO ARCHITECT PLLC105/24/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
TURNKEY CONTRACTING403/21/2026
ADVANCED BUILDERS SERVICES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GOLDEN GATE BAPAZ CONSTRUGeneral Contractor303/21/2026
MABE GROUP INCGeneral Contractor207/08/2026
DOUG'S PLBG & HTG SERV COFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CENTURY TESTING & CONSULT4081405/29/2024
Building Lifecycle
All (94)Filed (7)Permit Issued (4)Signed Off (3)Violation (48)Inspection (2)Objection (14)Special Inspection (16)
04/30/2026
Violation issued (HPD, open)
A
02/02/2026
Violation issued (HPD, open)
A
02/02/2026
Violation issued (HPD, closed)
B
02/02/2026
Violation issued (HPD, open)
B
02/02/2026
Violation issued (HPD, open)
A
11/18/2025
Violation issued (HPD, closed)
I
06/05/2025
Violation issued (HPD, closed)
A
11/25/2024
Violation issued (HPD, closed)
I
07/02/2024
Signed off — Alteration
INSTALLATION OF SPRINKLER SYSTEM FOR NEW BUILDING
X00416290-I1
06/17/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/07/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
05/29/2024
Filed — Alteration
INSTALLATION OF SPRINKLER SYSTEM FOR NEW BUILDING
X00416290-P2
05/15/2024
Signed off — Alteration
structural design of 1st, 2nd, roof and stair roof framing and bearing system
X00677601-I1
05/11/2024
Signed off — Alteration
INSTALLATION OF NEW CONSTRUCTION FENCE AS PER PLAN.FILING IN CONJUNCTION OFBIS JOB#220488149
X00521174-I1
05/10/2024
Special inspection requirement — Sprinkler Systems
ALDO BRAVO
04/02/2024
Violation issued (HPD, closed)
A
11/16/2023
Violation issued (HPD, closed)
I
09/15/2023
Special inspection requirement — Structural Steel - High Strength Bolting
ALDO BRAVO
09/15/2023
Special inspection requirement — Masonry
ALDO BRAVO
09/15/2023
Special inspection requirement — Structural Steel - Welding
ALDO BRAVO
09/15/2023
Special inspection requirement — Structural Steel - Details
ALDO BRAVO
09/15/2023
Special inspection requirement — Structural Cold-Formed Steel
ALDO BRAVO
09/15/2023
Special inspection requirement — Concrete - Cast-In-Place
ALDO BRAVO
09/15/2023
Special inspection requirement — Final
ALDO BRAVO
09/14/2023
Filed — Alteration
structural design of 1st, 2nd, roof and stair roof framing and bearing system
X00677601-P2
09/13/2023
Permit issued — Sprinklers
X00416290-I1-EW-SP
05/15/2023
Permit issued — Structural
X00677601-I1-ST
05/11/2023
Permit issued — Construction Fence
X00521174-I1-FN
03/16/2023
Violation issued (HPD, closed)
A
12/19/2022
Filed — Alteration
structural design of 1st, 2nd, roof and stair roof framing and bearing system
X00677601-P1
12/15/2022
Special inspection requirement — Concrete - Cast-In-Place
12/15/2022
Special inspection requirement — Masonry
12/15/2022
Special inspection requirement — Structural Cold-Formed Steel
12/15/2022
Special inspection requirement — Structural Steel - Details
12/15/2022
Special inspection requirement — Structural Steel - High Strength Bolting
12/15/2022
Special inspection requirement — Structural Steel - Welding
12/15/2022
Special inspection requirement — Final
11/03/2022
Violation issued (HPD, closed)
I
10/13/2022
Filed — Alteration
INSTALLATION OF SPRINKLER SYSTEM FOR NEW BUILDING
X00416290-P1
10/04/2022
Special inspection requirement — Sprinkler Systems
04/27/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/10/2022
Objection raised — Fire_Protection
03/10/2022
Objection resolved — Addressed
03/10/2022
Objection raised — Structural
03/10/2022
Objection resolved — Addressed
03/10/2022
Objection raised — Structural
03/10/2022
Objection resolved — Addressed
03/10/2022
Objection raised — Structural
03/10/2022
Objection resolved — Addressed
03/10/2022
Objection raised — Admin
03/10/2022
Objection resolved — Addressed
03/10/2022
Objection raised — Structural
03/10/2022
Objection resolved — Addressed
03/10/2022
Objection raised — Other
03/10/2022
Objection resolved — Addressed
03/04/2022
Filed — Alteration
structural design of 1st, 2nd, roof and stair roof framing and bearing system
X00677601-I1
02/17/2022
Violation issued (HPD, closed)
A
02/17/2022
Violation issued (HPD, closed)
I
02/03/2022
Violation issued (ECB, closed)
Construction
02/03/2022
Violation issued (ECB, closed)
Construction
Latest 60 of 94 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offDOUG'S PLBG & HTG SERV CO09/13/2023
DOB NOWStructuralSigned-offAB BUILDERS NY05/15/2023
DOB NOWConstruction FenceSigned-offAB BUILDERS NY05/11/2023
DOB NOWConstruction FenceSigned-offGOLDEN GATE BAPAZ CONSTRU09/08/2021
BIS—ISSUEDAG CONSTRUCTION GROUP COR06/19/2009
BISEQISSUEDCOLGATE SCAFF & EQUIP CO04/03/2009
1 project · most recent 07/08/2024
General Wiring
FiledStatusContractorScope
07/08/2024CompleteACCURATE ELEC'L CORP.General Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
06/17/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/07/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
05/10/2024Sprinkler SystemsALDO BRAVOspecial
09/15/2023Structural Steel - High Strength BoltingALDO BRAVOspecial
09/15/2023MasonryALDO BRAVOspecial
09/15/2023Structural Steel - WeldingALDO BRAVOspecial
09/15/2023Structural Steel - DetailsALDO BRAVOspecial
09/15/2023Structural Cold-Formed SteelALDO BRAVOspecial
09/15/2023Concrete - Cast-In-PlaceALDO BRAVOspecial
09/15/2023FinalALDO BRAVOprogress
12/15/2022Concrete - Cast-In-Place—special
12/15/2022Masonry—special
12/15/2022Structural Cold-Formed Steel—special
12/15/2022Structural Steel - Details—special
12/15/2022Structural Steel - High Strength Bolting—special
12/15/2022Structural Steel - Welding—special
12/15/2022Final—progress
10/04/2022Sprinkler Systems—special
▾Documents — 60 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch4
08/25/2026X00521174-I1Request digital key ↗
08/23/2026X00677601-P2Request digital key ↗
08/23/2026X00677601-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Sprinkler3
08/21/2026X00416290-P1Request digital key ↗
08/21/2026X00416290-I1Request digital key ↗
08/21/2026X00416290-P2Request digital key ↗
▸Applications & Permits10
▸BISPLAN / WORK APPROVAL APPLICATION9
09/08/2022220747093Open ↗
09/02/2022220747093Open ↗
08/29/2022220747093Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION1
04/03/2009220000736Open ↗
▸Zoning, Tax Lot & Property Records3
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
08/10/2022220747093Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
08/10/2022220747093Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
08/10/2022220747093Open ↗
▸Seals & Professional Certifications21
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/25/2026X00521174-I1Open ↗
08/23/2026X00677601-P2Open ↗
08/23/2026X00677601-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/02/2026X00677601-I1Open ↗
09/02/2026X00677601-I1Open ↗
09/02/2026X00677601-I1Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
12/07/2010220000736Open ↗
12/07/2010220000736Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
09/29/2016220553194Open ↗
04/03/2009220000736Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/29/2016220553194Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
04/03/2009220000736Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/02/2026X00677601-I1Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
09/29/2016220553194Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
04/03/2009220000736Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
05/07/2009220005651Open ↗
▸Approvals, Objections & Sign-offs7
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
12/07/2010220000736Open ↗
11/12/2010220000736Open ↗
07/02/2010220000736Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
11/19/2010220000736Open ↗
07/02/2010220000736Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
05/07/2009220005651Open ↗
04/03/2009220000736Open ↗
▸Filing & Intake Forms6
▸BISEFILING COVER SHEET4
06/17/2022220747093Open ↗
09/29/2016220553194Open ↗
05/07/2009220005651Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION2
09/13/2022220747093Open ↗
06/22/2022220747093Open ↗
▸Other Documents3
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
08/10/2022220747093Open ↗
08/10/2022220747093Open ↗
▸BISPLOT DIAGRAM1
08/10/2022220747093Open ↗