← Back
Two family converted from one family
76-24 264 STREET
QUEENS · Glen Oaks-Floral Park-New Hyde Park · BIN 4174002
💬 Discuss this project
1950Year Built
1.67Stories
B3Building Class
R2AZoning
1,147 sfGross Floor Area
2Units
2 Open Violations ▸FDNY Report ↗
Two family converted from one family · 4,000 sf lot · 0.29 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar1p · 1 filing · 4 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/31/2024$675K—Private party → Private party$588/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASKON ARCHITECTS, P.C.206/16/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC RAPID CONSTRUCTION203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRI CITY MECHANICAL GROUP CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ASKON ARCHITECT, P.C.3596110/19/2024
Building Lifecycle
All (27)Filed (2)Permit Issued (1)Violation (5)Inspection (4)Objection (14)Special Inspection (1)
10/30/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
09/23/2025
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
08/19/2025
Objection resolved — Addressed
08/19/2025
Objection resolved — Addressed
07/02/2025
Objection raised — Scope
07/02/2025
Objection raised — Inspections
07/02/2025
Objection resolved — Addressed
07/02/2025
Objection raised — Scope
06/16/2025
Filed — Alteration
AMEND PLAN AND RISER DIAGRAM
Q01121928-I1
06/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/21/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/07/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/04/2025
Violation issued (ECB, closed)
Unknown
04/04/2025
Violation issued (ECB, closed)
Construction
04/04/2025
Violation issued (ECB, open)
Unknown
12/16/2024
Permit issued — Plumbing
Q01123193-I1-PL
11/15/2024
Objection resolved — Addressed
11/15/2024
Objection resolved — Addressed
11/15/2024
Objection resolved — Addressed
11/14/2024
Objection resolved — Addressed
10/25/2024
Objection raised — Other
10/25/2024
Objection raised — Other
10/25/2024
Objection raised — Other
10/25/2024
Objection raised — Other
10/19/2024
Filed — Alteration
Q01123193-I1
09/13/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/03/2007
Violation issued (ECB, closed)
Zoning
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedFLAVIO MECHANICAL CORP12/16/2024
BISOTISSUEDANAND J. SOLANKI, P.E.03/20/2003
2 projects · most recent 06/16/2025
Gas Water/Sanitary
FiledStatusContractorScope
06/16/2025——Gas
10/19/2024Permit IssuedTRI CITY MECHANICAL GROUPGas, Water/Sanitary
1 project · most recent 04/20/2026
General Wiring
FiledStatusContractorScope
04/20/2026CompleteDM ELECTRICAL CORPORATIONGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
10/30/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/23/2025No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
04/21/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/07/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
06/16/2025Fire-Resistant Penetrations and Joints—special
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/21/2026Q01123193-I1Request digital key ↗
08/21/2026Q01123193-S2Request digital key ↗
08/20/2026Q01121928-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026Q01123193-S1Open ↗
08/13/2026Q01123193-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/21/2026Q01123193-I1Open ↗
08/21/2026Q01123193-S2Open ↗
08/13/2026Q01121928-I1Open ↗