← Back
One story retail building
760 MCDONALD AVENUE
BROOKLYN · BIN 3336274
💬 Discuss this project
1933Year Built
1Stories
K1Building Class
M1-1Zoning
2,000 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story retail building · Owner of record: 760 MCDONALD LLC · 2,000 sf lot · 1 FAR built · Flood zone X
Locations of Work
Mechanical
Roof1p · 1 filing · 5 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/08/2022$1.1M—Private party → 760 MCDONALD LLC$550/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASHRAF CORP204/19/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MA DESIGNS NYC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIGH SKY CONSTRUCTION INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ASHRAF CORPORATION1973104/19/2022
FRANCISCO D. PEREZ PE3306104/19/2022
Building Lifecycle
All (26)Filed (2)Permit Issued (1)Violation (1)Objection (16)Special Inspection (6)
06/10/2022
Permit issued — Mechanical Systems
B00720309-I1-GC-CX
05/24/2022
Objection resolved — Addressed
05/23/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
AKM HOQUE
05/18/2022
Objection resolved — Addressed
05/14/2022
Special inspection requirement — Energy Code Compliance Inspections
AKM HOQUE
05/05/2022
Objection resolved — Addressed
05/05/2022
Objection resolved — Addressed
05/05/2022
Objection resolved — Addressed
05/05/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
AKM HOQUE
04/27/2022
Objection resolved — Addressed
04/27/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
FRANCISCO PEREZ
04/26/2022
Objection resolved — Addressed
04/26/2022
Objection resolved — Addressed
04/25/2022
Objection raised — Admin
04/25/2022
Objection raised — Admin
04/25/2022
Objection raised — Structural
04/25/2022
Objection raised — Fire_Protection
04/25/2022
Objection raised — Inspections
04/25/2022
Objection raised — Admin
04/25/2022
Objection raised — Fire_Protection
04/25/2022
Objection raised — Inspections
04/19/2022
Filed — Alteration
INSTALL NEW KITCHEN COOKING EQUIPMENT AND PLUMBING FIXTURES AS PER PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00720311-I1
04/19/2022
Filed — Alteration
MINOR INTERIOR RENOVATION AND INSTALL NEW HOOD AT THE FIRST FLOOR COMMERCIAL SPACE AS PER PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00720309-I1
04/17/2022
Special inspection requirement — Mechanical Systems
FRANCISCO PEREZ
04/17/2022
Special inspection requirement — Final
Jay Kavi
05/10/2006
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedHIGH SKY CONSTRUCTION INC06/10/2022
BISOTISSUEDQUINTUNA SERVICE CORP10/19/2017
BISPLISSUEDPRECISION PLBG SVCS., INC10/19/2017
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
05/23/2022HVAC-R and service water piping design and insulationAKM HOQUEenergy_progress
05/14/2022Energy Code Compliance InspectionsAKM HOQUEprogress
05/05/2022Fire-Resistant Penetrations and JointsAKM HOQUEspecial
04/27/2022Fire-Resistant Penetrations and JointsFRANCISCO PEREZspecial
04/17/2022Mechanical SystemsFRANCISCO PEREZspecial
04/17/2022FinalJay Kaviprogress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/29/2026B00720309-I1Request digital key ↗
08/14/2026B00720311-I1Request digital key ↗
▸Applications & Permits8
▸BISWORK PERMIT APPLICATION4
10/23/2017321388734Open ↗
10/23/2017321388734Open ↗
10/23/2017321388734Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION2
11/30/2017321388734Open ↗
10/02/2017321388734Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION2
02/21/2018321388734Open ↗
11/11/2017321388734Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/29/2026B00720311-I1Open ↗
08/13/2026B00720309-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
10/02/2017321388734Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/02/2017321388734Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/02/2017321388734Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/26/2026B00720309-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026B00720309-I1Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
11/30/2017321388734Open ↗
10/02/2017321388734Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/14/2026B00720311-I1Open ↗
08/13/2026B00720309-I1Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
10/02/2017321388734Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
10/02/2017321388734Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
09/29/2017321388734Open ↗
▸BISADDITIONAL INFORMATION1
11/30/2017321388734Open ↗