| Owner | Filings | Most Recent |
|---|---|---|
| Triple Power II | 9 | 03/22/2026 |
| Exit 14 Convenient | 5 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 06/23/2022 | $1.6M | — | Private party → 7603 WU INC. | $473/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| Skypeak | 1 | 08/27/2025 |
| Ayala Engineering | 2 | 07/03/2024 |
| JX Flame Solution | 2 | 08/01/2023 |
| J&R Design and Inspection | 3 | 04/26/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| High Quality 338 | 6 | 03/21/2026 |
| Viben Building | 4 | 03/21/2026 |
| Insha Building Consultants | 2 | 03/21/2026 |
| SUN | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| American Standard P&H Cororp | Plumbing | 4 | 07/08/2026 |
| BG Construction NY | General Contractor | 3 | 03/21/2026 |
| Greener County | General Contractor | 3 | 03/21/2026 |
| Timing Construction Team* | General Contractor | 3 | 03/21/2026 |
| High Quality Construction | General Contractor | 1 | 07/08/2026 |
| Superior Plumbing & Heating | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Ayala Engineering | 9207 | 2 | 07/03/2024 |
| NKM Engineering | 6244 | 3 | 04/26/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | Greener County Construction | 09/02/2025 |
| DOB NOW | Plumbing | Permit Issued | Superior Plumbing & Heating | 08/14/2024 |
| DOB NOW | Boiler Equipment | Signed-off | American Standard P&H Cororp | 07/24/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | BG Construction NY | 07/15/2024 |
| DOB NOW | Plumbing | Signed-off | American Standard P&H Cororp | 05/20/2024 |
| DOB NOW | Boiler Equipment | Signed-off | American Standard P&H Cororp | 05/05/2023 |
| DOB NOW | Plumbing | Signed-off | American Standard P&H Cororp | 05/03/2023 |
| DOB NOW | General Construction | Signed-off | High Quality Construction | 04/28/2023 |
| DOB NOW | General Construction | Signed-off | Timing Construction Team* | 02/01/2023 |
| BIS | MH | ISSUED | Herco Machinery | 09/26/1991 |
| BIS | FS | ISSUED | Herco Machinery | 09/26/1991 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/03/2024 | Permit Issued | BG Construction NY | Ventilation Systems | Ventilation Dayton 56JN93 4,800 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/01/2023 | Permit Issued | KJK Electric | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 11/08/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 08/23/2024 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 08/23/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 08/02/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 08/02/2024 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 08/02/2024 | Pass-Final Boiler Equipment Inspection | Pass | View ↗ |
| 07/01/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 06/25/2024 | No Access-Final PL - Up to 3 Requested Floors | No Access | View ↗ |
| 05/20/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 10/16/2023 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/01/2024 | Fenestration areas | Pablo Ayala | energy_progress |
| 07/01/2024 | Fire-Resistance Rated Construction | Pablo Ayala | progress |
| 07/01/2024 | Air barrier - visual inspection | Pablo Ayala | energy_progress |
| 07/01/2024 | Fenestration and door U-factor and product ratings | Pablo Ayala | energy_progress |
| 07/01/2024 | Fenestration air leakage | Pablo Ayala | energy_progress |
| 06/26/2024 | Fire-Resistant Penetrations and Joints | Pablo Ayala | special |
| 06/26/2024 | Tenant Protection Plan Compliance | Pablo Ayala | special |
| 06/26/2024 | Mechanical Systems | Pablo Ayala | special |
| 06/26/2024 | Energy Code Compliance Inspections | Pablo Ayala | progress |
| 06/26/2024 | Final | Pablo Ayala | progress |
| 06/26/2024 | HVAC-R and service water heating equipment | Pablo Ayala | energy_progress |
| 06/26/2024 | HVAC-R and service water piping design and insulation | Pablo Ayala | energy_progress |
| 06/26/2024 | Interior lighting power | Pablo Ayala | energy_progress |
| 06/26/2024 | HVAC-R and service water heating system controls | Pablo Ayala | energy_progress |
| 04/26/2023 | Tenant Protection Plan Compliance | NARESH MAHANGU | special |
| 04/21/2023 | Heating Systems | NARESH MAHANGU | special |
| 04/21/2023 | Fire-Resistant Penetrations and Joints | NARESH MAHANGU | special |
| 04/21/2023 | HVAC-R and service water heating equipment | NARESH MAHANGU | energy_progress |
| 04/21/2023 | HVAC-R and service water heating system controls | NARESH MAHANGU | energy_progress |
| 04/21/2023 | Maintenance information | NARESH MAHANGU | energy_progress |
| 04/14/2023 | HVAC-R and service water heating equipment | NARESH MAHANGU | energy_progress |
| 04/14/2023 | Energy Code Compliance Inspections | NARESH MAHANGU | progress |
| 04/14/2023 | Fire-Resistant Penetrations and Joints | NARESH MAHANGU | special |
| 04/14/2023 | Fire-Resistance Rated Construction | NARESH MAHANGU | progress |
| 04/14/2023 | Fire-Resistant Penetrations and Joints | NARESH MAHANGU | special |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| Exit 14 Convenient | Retail | Floor 1 | Project B01276549 |