← Back
Three families
766 OLMSTEAD AVENUE
BRONX · Castle Hill-Unionport · BIN 2022340
💬 Discuss this project
1930Year Built
2Stories
C0Building Class
R3-2Zoning
3,880 sfGross Floor Area
3Units
0 Open Violations
Three families · 3,002 sf lot · 1.29 FAR built · Flood zone X
Locations of Work
Architecture
Roof3p · 1 filing · 17 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC201/31/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CENTURION SOLAR ENERGYGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854201/31/2025
Building Lifecycle
All (18)Filed (2)Signed Off (1)Violation (1)Objection (4)Special Inspection (10)
02/19/2025
Signed off — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
X01046966-I1
02/07/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
02/07/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
02/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
02/07/2025
Special inspection requirement — Final
TOM PETERSEN
02/07/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
01/31/2025
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
X01046966-P1
09/11/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
09/11/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
09/11/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
09/11/2024
Special inspection requirement — Final
TOM PETERSEN
09/11/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
05/24/2024
Objection resolved — Addressed
05/24/2024
Objection resolved — Addressed
05/13/2024
Objection raised — Structural
05/13/2024
Objection raised — Scope
05/07/2024
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
X01046966-I1
12/21/2018
Violation issued (ECB, closed)
Construction
Nothing on file for this building.
2 projects · most recent 08/06/2024
FiledStatusContractorScope
08/06/2024Permit IssuedBERGER QUALITY ELEC'L CON3 meters
05/05/2024CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
02/07/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
02/07/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
02/07/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
02/07/2025FinalTOM PETERSENprogress
02/07/2025Energy Code Compliance InspectionsTOM PETERSENprogress
09/11/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
09/11/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
09/11/2024Energy Code Compliance InspectionsTOM PETERSENprogress
09/11/2024FinalTOM PETERSENprogress
09/11/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026X01046966-P1Request digital key ↗
08/14/2026X01046966-I1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
08/24/2026X01046966-I1Open ↗
08/24/2026X01046966-I1Open ↗
08/24/2026X01046966-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/24/2026X01046966-I1Open ↗
08/24/2026X01046966-I1Open ↗
08/22/2026X01046966-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026X01046966-I1Open ↗
08/21/2026X01046966-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026X01046966-P1Open ↗
08/14/2026X01046966-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01046966-I1Open ↗