← Back
One family attached or semi-detached
77-01 82 STREET
QUEENS · BIN 4093048
💬 Discuss this project
1930Year Built
2.75Stories
A5Building Class
R4BZoning
1,870 sfGross Floor Area
1Units
0 Open Violations
One family attached or semi-detached · 2,767 sf lot · 0.68 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Cellar2p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/19/2023$998K—Private party → Private party$534/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TL ARCHITECT, PLLC102/23/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ACON CONSTRUCTION/REN CORGeneral Contractor203/21/2026
Building Lifecycle
All (16)Filed (1)Permit Issued (1)Signed Off (1)Violation (1)Objection (6)Special Inspection (6)
02/25/2025
Signed off — Alteration
Interior renovation and replacement of windows and door on 1st floor as per plan. No change in use, egress, or occupancy.
Q01002684-I1
03/29/2024
Permit issued — General Construction
Q01002684-I1-GC
03/06/2024
Objection resolved — Addressed
03/06/2024
Objection resolved — Addressed
03/06/2024
Objection resolved — Addressed
03/06/2024
Special inspection requirement — Interior lighting power
Timothy Lee
02/28/2024
Objection raised — Energy
02/28/2024
Objection raised — Fire_Protection
02/28/2024
Objection raised — Other
02/23/2024
Filed — Alteration
Interior renovation and replacement of windows and door on 1st floor as per plan. No change in use, egress, or occupancy.
Q01002684-I1
02/23/2024
Special inspection requirement — Energy Code Compliance Inspections
Timothy Lee
02/23/2024
Special inspection requirement — Insulation placement and R values
Timothy Lee
02/23/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Timothy Lee
02/23/2024
Special inspection requirement — Air barrier - visual inspection
Timothy Lee
02/17/2024
Special inspection requirement — Final
Timothy Lee
05/23/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offACON CONSTRUCTION/REN COR03/29/2024
1 project · most recent 09/22/2023
FiledStatusContractorScope
09/22/2023CompleteELMAC ELECTRIC INC.—
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
03/06/2024Interior lighting powerTimothy Leeenergy_progress
02/23/2024Energy Code Compliance InspectionsTimothy Leeprogress
02/23/2024Insulation placement and R valuesTimothy Leeenergy_progress
02/23/2024Fenestration and door U-factor and product ratingsTimothy Leeenergy_progress
02/23/2024Air barrier - visual inspectionTimothy Leeenergy_progress
02/17/2024FinalTimothy Leeprogress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/23/2026Q01002684-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature6
08/25/2026Q01002684-I1Open ↗
08/25/2026Q01002684-I1Open ↗
08/25/2026Q01002684-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/23/2026Q01002684-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/23/2026Q01002684-I1Open ↗