← Back
Three families
779 HANCOCK STREET
BROOKLYN · Bedford-Stuyvesant (East) · BIN 3045968
💬 Discuss this project
1899Year Built
2Stories
C0Building Class
R6BZoning
3,412 sfGross Floor Area
3Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Three families · 2,000 sf lot · 1.71 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
URENA CONSTRUCTION & DESIGN907/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SOTIR ASSOCIATES307/08/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
INFINITI ESC PLUMBING CORPlumbing707/08/2026
ODALIS URENAGeneral Contractor103/21/2026
URENA CONST & DESIGN INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE2050109/07/2021
Building Lifecycle
All (27)Filed (3)Permit Issued (2)Signed Off (2)Violation (13)Inspection (5)Special Inspection (2)
11/20/2025
Violation issued (HPD, closed)
I
06/09/2025
Violation issued (HPD, closed)
A
04/10/2024
Violation issued (HPD, closed)
A
11/22/2023
Violation issued (HPD, closed)
I
03/23/2023
Violation issued (HPD, closed)
A
11/14/2022
Violation issued (HPD, closed)
I
10/26/2022
Signed off — Alteration
REPLACE PLUMBING FIXTURES AS PER PLANS. IN CONJUNCTION WITH GC APP #B00578104
B00578143-I1
10/24/2022
Signed off — Alteration
B00578104-I1
10/24/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/21/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/19/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/12/2022
Special inspection requirement — Energy Code Compliance Inspections
Hany Demetry
07/08/2022
Filed — Alteration
REPLACE PLUMBING FIXTURES AS PER PLANS. IN CONJUNCTION WITH GC APP #B00578104
B00578143-P1
07/08/2022
Special inspection requirement — Energy Code Compliance Inspections
Hany Demetry
02/25/2022
Violation issued (HPD, closed)
A
12/03/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/03/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/19/2021
Permit issued — Plumbing
B00578143-I1-PL
11/18/2021
Filed — Alteration
REPLACE PLUMBING FIXTURES AS PER PLANS. IN CONJUNCTION WITH GC APP #B00578104
B00578143-I1
09/10/2021
Permit issued — General Construction
B00578104-I1-GC
09/07/2021
Filed — Alteration
B00578104-I1
04/09/2021
Violation issued (HPD, closed)
A
10/30/2019
Violation issued (HPD, closed)
I
11/09/2016
Violation issued (HPD, closed)
I
10/09/2015
Violation issued (HPD, closed)
I
04/13/1998
Violation issued (HPD, open)
B
04/13/1998
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR11/19/2021
DOB NOWGeneral ConstructionSigned-offURENA CONST & DESIGN INC09/10/2021
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/24/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/21/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/19/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/03/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/03/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
07/12/2022Energy Code Compliance InspectionsHany Demetryprogress
07/08/2022Energy Code Compliance InspectionsHany Demetryprogress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
09/01/2026B00578104-I1Request digital key ↗
08/31/2026B00578143-P1Request digital key ↗
08/31/2026B00578143-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
09/01/2026B00578104-I1Open ↗
08/31/2026B00578143-I1Open ↗
08/31/2026B00578143-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026B00578143-I1Open ↗
08/23/2026B00578143-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/01/2026B00578104-I1Open ↗
08/31/2026B00578143-I1Open ↗
08/31/2026B00578143-P1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00578104-I1Open ↗