← Back
Two family converted from one family
78-55 80 STREET
QUEENS · Glendale · BIN 4093570
💬 Discuss this project
1920Year Built
2.75Stories
B3Building Class
R4-1Zoning
1,553 sfGross Floor Area
2Units
Two family converted from one family · 1,665 sf lot · 0.93 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JBA107/25/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WILLIAM JAMES BUSHELL CORGeneral Contractor303/21/2026
AMBER ELECTL CONTNG INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WORLD DESIGN ARCHITECTURE9323107/25/2024
Building Lifecycle
All (7)Filed (1)Permit Issued (1)Special Inspection (5)
07/31/2024
Permit issued — Solar
Q01086401-I1-SL
07/25/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY OR EGRESS. NO CHANGE IN BULK
Q01086401-I1
07/25/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Alicea
07/25/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
William Alicea
07/25/2024
Special inspection requirement — Energy Code Compliance Inspections
JEFFREY BELL
07/25/2024
Special inspection requirement — Final
JEFFREY BELL
07/25/2024
Special inspection requirement — Air barrier - visual inspection
JEFFREY BELL
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offWILLIAM JAMES BUSHELL COR07/31/2024
2 projects · most recent 07/12/2024
FiledStatusContractorScope
07/12/2024Permit IssuedAMBER ELECTL CONTNG INC1 meters
06/26/2024Permit IssuedAMBER ELECTL CONTNG INC—
1 project · most recent 07/25/2024
FiledStatusContractorScope
07/25/2024Signed-offWILLIAM JAMES BUSHELL COR10 panels, 5.5 kw, 680.56 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/25/2024Fire-Resistant Penetrations and JointsWilliam Aliceaspecial
07/25/2024Structural Stability – Alterations of existing buildingsWilliam Aliceaspecial
07/25/2024Energy Code Compliance InspectionsJEFFREY BELLprogress
07/25/2024FinalJEFFREY BELLprogress
07/25/2024Air barrier - visual inspectionJEFFREY BELLenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026Q01086401-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
09/01/2026Q01086401-I1Open ↗
09/01/2026Q01086401-I1Open ↗
09/01/2026Q01086401-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q01086401-I1Open ↗
09/01/2026Q01086401-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/21/2026Q01086401-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/21/2026Q01086401-I1Open ↗