← Back
Church, synagogue, chapel
784 EASTERN PARKWAY
BROOKLYN · BIN 3033034
💬 Discuss this project
1925Year Built
4Stories
M1Building Class
R6Zoning
15,500 sfGross Floor Area
4Units
4 Open Violations ▸FDNY Report ↗
Church, synagogue, chapel · 6,029 sf lot · 2.57 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BUILDWELL GROUP407/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STRUCTURAL ENGINEERING TECHNOLOGIES108/14/2026
SYED ENGINEERING, P.C.111/08/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ADVANCED BUILDERS SERVICES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ARROYO, RAFAELElectrical103/21/2026
CHAIM, LEZERElectrical103/21/2026
ELLIS, HERBERTElectrical103/21/2026
LELIS, ARILSONElectrical103/21/2026
MICHAELOFF, STEVENElectrical103/21/2026
NEU, RICHARDElectrical103/21/2026
RICHARD NEUElectrical103/21/2026
SERGIO GIANNACHIElectrical103/21/2026
SIGMOND FRIEDElectrical103/21/2026
AFFINITY ASSOCIATES 1 INCGeneral Contractor109/10/2026
BUILDWELL GROUP INCGeneral Contractor107/08/2026
Building Lifecycle
All (14)Filed (2)Permit Issued (2)Violation (6)Special Inspection (4)
09/09/2026
Permit issued — Structural
B01454168-I1-GC-CX
08/14/2026
Filed — Alteration
Application filed for permanent backfilling, bracing, and shoring of an excavation approximately 4 feet deep and 60 feet long.
B01444157-I1
08/12/2026
Special inspection requirement — Concrete - Cast-In-Place
08/12/2026
Special inspection requirement — Construction Operations Influencing Adjacent Structures
08/11/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
08/11/2026
Special inspection requirement — Final
03/20/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/20/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/20/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/10/2024
Violation issued (ECB, closed)
Construction
01/10/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/10/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/12/2019
Permit issued — Sidewalk Shed
B00257277-I1-SH
11/08/2019
Filed — Alteration
B00257277-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offAFFINITY ASSOCIATES 1 INC09/09/2026
DOB NOWSidewalk ShedPermit IssuedBUILDWELL GROUP INC11/12/2019
BISSPISSUEDSIRINA FIRE PROTECTION CORP01/07/1994
BISEQRE-ISSUEDURBAN SUBSTRUCTURES04/11/1991
1 project · most recent 11/02/2019
FiledStatusContractorScope
11/02/2019Permit IssuedRICHARD NEU—
1 project · most recent 08/14/2026
Concrete
FiledStatusContractorScope
08/14/2026——Concrete
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
08/12/2026Concrete - Cast-In-Place—special
08/12/2026Construction Operations Influencing Adjacent Structures—special
08/11/2026Structural Stability – Alterations of existing buildings—special
08/11/2026Final—progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/02/2026B00257277-I1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/16/2026B01444157-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/16/2026B01444157-I1Open ↗
08/13/2026B00257277-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWTenant Protection Plan1
08/13/2026B00257277-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter2
08/16/2026B01444157-I1Open ↗
08/13/2026B00257277-I1Open ↗