← Back
Two family converted from one family
789 LEXINGTON AVENUE
BROOKLYN · Bedford-Stuyvesant (East) · BIN 3044165
💬 Discuss this project
1899Year Built
2Stories
B3Building Class
R6BZoning
1,428 sfGross Floor Area
2Units
3 Open Violations ▸FDNY Report ↗
Two family converted from one family · 1,700 sf lot · 0.84 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalPlumbing
Roof1 filing · 14 docs
Floor 22p · 2 filings · 7 docs
Floor 12p · 2 filings · 7 docs
Cellar1p · 1 filing · 4 docs
Basement3p · 3 filings · 20 docs
Sub-Basement2p · 2 filings · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NY103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/27/2023$1.3M—— → —$900/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC209/02/2026
KELLEY DESIGN206/06/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PROGENY MANAGEMENT & EXPEDITING SER403/21/2026
KAMTECH RESTORATION CORP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GUCI ENTERPRISES INCGeneral Contractor303/21/2026
BELLA CRUISE ELECTRICALElectrical103/22/2026
ORPHEOUS ELECTRICAL INCElectrical103/22/2026
KAMTECH RESTORATION CORPGeneral Contractor104/09/2026
XPRESS PLBG AND HTG LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802209/02/2026
Building Lifecycle
All (39)Filed (4)Permit Issued (3)Signed Off (2)Violation (17)Inspection (3)Special Inspection (10)
09/02/2026
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
B01252030-P1
09/02/2026
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
09/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
09/02/2026
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
09/02/2026
Special inspection requirement — Final
Kaijin Liang
06/02/2026
Violation issued (HPD, open)
B
07/23/2025
Permit issued — Solar
B01252030-I1-SL
07/07/2025
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
B01252030-I1
07/07/2025
Special inspection requirement — Final
Kaijin Liang
07/07/2025
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
07/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
07/07/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
07/07/2025
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
05/07/2024
Signed off — Alteration
RENOVATION OF (2) APARTMENTS. APARTMENT 1: BASEMENT REPL 3 PIECE BATHROOM AND KITCHEN SINK, DW, & CLOTHES WASHER. FIRST FLOOR REPL 3 PIECE BATHROOM. APARTMENT 2: REPL 3 PIECE BATHROOM AND KITCHEN SINK, DW, & CLOTHES WASHER. INSTALL NEW GAS HEATER.
B00877694-I1
03/06/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/06/2024
Violation issued (ECB, open)
Unknown
02/28/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/01/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/26/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/15/2023
Signed off — Alteration
RENOVATE 2 APARTMENTS WITH MINOR PARTITION WORK. NO CHANGE IN USE, EGRESS, OR OCCUPANCY. THIS PERMIT IS TO RESOLVE WORK WITHOUT A PERMIT VIOLATIONS.
B00877693-I1
07/26/2023
Permit issued — Plumbing
B00877694-I1-PL
07/25/2023
Permit issued — General Construction
B00877693-I1-GC
06/06/2023
Filed — Alteration
RENOVATION OF (2) APARTMENTS. APARTMENT 1: BASEMENT REPL 3 PIECE BATHROOM AND KITCHEN SINK, DW, & CLOTHES WASHER. FIRST FLOOR REPL 3 PIECE BATHROOM. APARTMENT 2: REPL 3 PIECE BATHROOM AND KITCHEN SINK, DW, & CLOTHES WASHER. INSTALL NEW GAS HEATER.
B00877694-I1
05/31/2023
Filed — Alteration
RENOVATE 2 APARTMENTS WITH MINOR PARTITION WORK. NO CHANGE IN USE, EGRESS, OR OCCUPANCY. THIS PERMIT IS TO RESOLVE WORK WITHOUT A PERMIT VIOLATIONS.
B00877693-I1
05/18/2023
Special inspection requirement — Final
Beth Kelley
05/02/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/09/2018
Violation issued (ECB, closed)
Construction
02/09/2018
Violation issued (ECB, closed)
Construction
02/09/2018
Violation issued (ECB, closed)
Construction
02/09/2018
Violation issued (ECB, closed)
Plumbing
04/24/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/24/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/24/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/24/2014
Violation issued (ECB, closed)
Unknown
01/24/2014
Violation issued (ECB, closed)
Construction
01/24/2014
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP07/23/2025
DOB NOWPlumbingSigned-offXPRESS PLBG AND HTG LLC07/26/2023
DOB NOWGeneral ConstructionSigned-offGUCI ENTERPRISES INC07/25/2023
4 projects · most recent 07/03/2025
General Wiring
FiledStatusContractorScope
07/03/2025CompleteBERGER QUALITY ELEC'L CON—
04/25/2024CompleteBELLA CRUISE ELECTRICAL—
11/29/2023CompleteBELLA CRUISE ELECTRICALGeneral Wiring
05/23/2023CompleteORPHEOUS ELECTRICAL INCGeneral Wiring
1 project · most recent 09/02/2026
FiledStatusContractorScope
09/02/2026Signed-offKAMTECH RESTORATION CORP11 panels, 5.06 kw, 771.71 roof_area_sqft
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
02/28/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/01/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/26/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
09/02/2026Air barrier - visual inspectionKaijin Liangenergy_progress
09/02/2026Fire-Resistant Penetrations and JointsKaijin Liangspecial
09/02/2026Energy Code Compliance InspectionsKaijin Liangprogress
09/02/2026FinalKaijin Liangprogress
07/07/2025FinalKaijin Liangprogress
07/07/2025Air barrier - visual inspectionKaijin Liangenergy_progress
07/07/2025Fire-Resistant Penetrations and JointsKaijin Liangspecial
07/07/2025Structural Stability – Alterations of existing buildingsKaijin Liangspecial
07/07/2025Energy Code Compliance InspectionsKaijin Liangprogress
05/18/2023FinalBeth Kelleyprogress
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/27/2026B00877693-I1Request digital key ↗
08/27/2026B00877694-I1Request digital key ↗
08/21/2026B01252030-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
01/31/2014320776291Open ↗
06/29/2013320776291Open ↗
▸Seals & Professional Certifications15
▸DOB NOWProgress Inspector Seal & Signature7
09/23/2026B01252030-P1Open ↗
09/23/2026B01252030-P1Open ↗
09/23/2026B01252030-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/15/2026B01252030-P1Open ↗
08/27/2026B00877694-I1Open ↗
08/13/2026B01252030-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026B01252030-P1Open ↗
08/29/2026B01252030-I1Open ↗
08/29/2026B01252030-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
06/29/2013320776291Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/15/2026B01252030-P1Open ↗
08/27/2026B00877694-I1Open ↗
08/13/2026B00877693-I1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/29/2013320776291Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
06/29/2013320776291Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
06/29/2013320776291Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
06/29/2013320776291Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
06/29/2013320776291Open ↗