← Back
Primarily 2 family with 1 store or office
79-17 ROOSEVELT AVENUE
QUEENS · BIN 4029973
💬 Discuss this project
1931Year Built
2Stories
S2Building Class
R6Zoning
2,418 sfGross Floor Area
3Units
0 Open Violations
Primarily 2 family with 1 store or office · 1,553 sf lot · 1.56 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KAY FUNG ENTERPRISES307/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EDWARD GLOEGGLER, PE104/29/2025
RIGID STRUCTURAL DESIGN, LLC204/01/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Rigid Structural Design, LLC403/21/2026
ADJ BUILDING CONSULTANT203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
INTERSYSTEMS INSTAL S&SGeneral Contractor303/21/2026
SCLAFMORE CONSTRUCTION LLGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GLOEGGLER ENGINEERING, PL9506204/29/2025
Building Lifecycle
All (30)Filed (3)Permit Issued (2)Signed Off (2)Violation (9)Objection (8)Special Inspection (6)
08/27/2025
Signed off — Alteration
Installation of a temporarily heavy-duty sidewalk shed per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
Q01199062-I1
07/23/2025
Signed off — Alteration
FACADE REPAIR IN RELATION TO ECB VIOLATION # 39129720Z. STRUCTURAL WORK. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q01207244-I1
07/09/2025
Permit issued — Structural
Q01207244-I1-ST
06/17/2025
Objection resolved — Addressed
06/17/2025
Objection resolved — Addressed
06/17/2025
Objection resolved — Addressed
06/05/2025
Objection resolved — Addressed
05/19/2025
Objection raised — Cost
05/19/2025
Objection raised — Scope
05/19/2025
Objection raised — Other
05/19/2025
Objection raised — Scope
04/29/2025
Filed — Alteration
FACADE REPAIR IN RELATION TO ECB VIOLATION # 39129720Z. STRUCTURAL WORK. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q01207244-I1
04/21/2025
Special inspection requirement — Structural Cold-Formed Steel
EDWARD GLOEGGLER
04/09/2025
Special inspection requirement — Tenant Protection Plan Compliance
EDWARD GLOEGGLER
04/08/2025
Special inspection requirement — Masonry
EDWARD GLOEGGLER
04/08/2025
Special inspection requirement — Structural Steel - Details
EDWARD GLOEGGLER
04/08/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
EDWARD GLOEGGLER
04/08/2025
Special inspection requirement — Final
EDWARD GLOEGGLER
04/01/2025
Filed — Alteration
Installation of a temporarily heavy-duty sidewalk shed per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
Q01199062-P1
03/28/2025
Permit issued — Sidewalk Shed
Q01199062-I1-SH
03/27/2025
Filed — Alteration
Installation of a temporarily heavy-duty sidewalk shed per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
Q01199062-I1
11/07/2024
Violation issued (ECB, closed)
Construction
11/08/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/2005
Violation issued (ECB, closed)
Quality of Life
02/10/2005
Violation issued (ECB, closed)
Quality of Life
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/13/1988
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offSCLAFMORE CONSTRUCTION LL07/09/2025
DOB NOWSidewalk ShedSigned-offINTERSYSTEMS INSTAL S&S03/28/2025
1 project · most recent 04/01/2025
FiledStatusContractorScope
04/01/2025Permit IssuedAURORA ELECL CONTG INC—
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
04/21/2025Structural Cold-Formed SteelEDWARD GLOEGGLERspecial
04/09/2025Tenant Protection Plan ComplianceEDWARD GLOEGGLERspecial
04/08/2025MasonryEDWARD GLOEGGLERspecial
04/08/2025Structural Steel - DetailsEDWARD GLOEGGLERspecial
04/08/2025Structural Stability – Alterations of existing buildingsEDWARD GLOEGGLERspecial
04/08/2025FinalEDWARD GLOEGGLERprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/20/2026Q01199062-I1Request digital key ↗
08/20/2026Q01199062-P1Request digital key ↗
08/20/2026Q01207244-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWSpecial Inspector Seal & Signature5
08/29/2026Q01207244-I1Open ↗
08/29/2026Q01207244-I1Open ↗
08/29/2026Q01207244-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/20/2026Q01199062-P1Open ↗
08/20/2026Q01199062-I1Open ↗
08/13/2026Q01207244-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/29/2026Q01207244-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1