ECB08/21/2026AT TIME OF INSPECTION OBSERVED SIDEWALK SHED AT EXPOSURE 1 CONSTRUCTION EQUIPMENT INSTALLATION ON SITE WITH AN EXPIRED PERMIT SHED ON FILE WITH THE DEPT OF BUILDINGS. PERMIT #B0037702-I1-SH EXPIRES 6/05/25. REM$1K due
ECB08/21/2026AT TIME OF INSPECTION OBSERVED SIDEWALK SHED ERECTED AT EXPOSURE 1 THEPROTECTION OF PEDESTRIANS DURING SIDEWALK SHED INSTALLED MUST BE SECURED. FOUNDATION MUDSILLS ARE LOOSE AND MISSING UNDERNEATH STEEL POST. R$2K due
ECB08/20/2026ATOI OBSERVED SIDEWALK SHED ERECTED AT GROUND FLOOR OF EXP.1 UNDER PERMIT #B00377702-I1-SH WHICH WAS OBSERVED TO HAVE EXPIRED ON 06/05/2025. VIOLATION ISSUED., RENEW PERMIT$1K due
DOB11/22/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB07/27/2023WORK WITHOUT A PERMIT. NOTED PARTITION WALLS ERECTED TO CREATE SLEEPING QUARTERS, KITCHENS WITH RESIDENTIAL SINK, BATHROOM 3PC (SINK, TOILET, TUB) ON 4TH FLOOR SUITE. REMEDY: OBTAIN PERMIT$2K due
ECB07/13/2023NOTE AT EXPOSURE #2, THE CONDITION TO THE FACADE IS STILL EXIST IN DISREPAIR, EXPOSED REBARS AND DAMAGES AT VARIOUS AT WINDOW SILL AND LINTEL, SEE SUMMONS 35548486K.$1K due
DOB01/12/2022FAILURE TO MAINTAIN EXTERIOR BLDG WALL&APPURTENANCES AT EAST AND SOUTH ELEVATIONS EXPO#1&2 OBSERVED SPALLED CONCRETE AND EXPSOED STEEL REIN FORCEMENT AT MULTIPLE LOCATIONS ALSO BOBSERVED AT SOUTH ELEVATION EXPO #2 BROKEN WINDOW GLASS AT MULTIPLE LOCATIONS.REMEDY:MAINTAIN EXTERIOR BUILDING WALL;REPAIR DEFECTIVE FACADE PROVIDE SAFETY MEASURES
DOB12/17/2021FAILURE TO PERFORM CATEGORY 5 INSPECTION
DOB08/13/2021FAILURE TO COMPLY WITH COMMISSIONER'S ORDER 291184(100520CLL0101SR) ISSUED ON 10/05/2020. AS OF 08/13/2021 OWNER HAS NOT COMPLIED WITH IMMEDIATE CURE ORDER. REMEDY: IMMED COMPLY WITH CODE AND COMMISSIONER'S ORDERS
DOB06/09/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB05/13/2021FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES.NOTED:OBSERVED@EXP2 WALLS IN DISREPAIR W/CRACKS&MISSING PCS OF CONCRETE EXPOSING REBAR.MAINTAIN EXTERIOR BLDG WALL.$1K due
ECB03/10/2021FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES NOTE AT EXP #2 THE MAOSNRY AND STUCCO WALL IS IN DISREAPIR WITH PIECES MISSING CRACKED CHIPPED AND SPALLING SOEM HAVE EXPOSED REBAR AND DAMAGE AT VARIOUS WI$2K due
DOB12/09/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB11/10/2020FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: NOTED: LOOSE STUCCO AT 2ND FL & BROKEN CONCRETE THROUGHOUT. REMEDY: REPAIR &/OR REPAIR.$1K due
DOB10/14/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB10/05/2020FTM FACADE AND APPURTENANCES. ON 7/22/2020 DOB INSPECTOR OBSERVED DEFECTIVE CONCRETE AT EXPOSURE #1: FALLEN PIECES OF CONCRETE FROM 4FL APPROX 6 INCHES: AT EXPOSURE #2: SPALLING AND FALLING CONCRETE INTO ALLEYWAY. REMEDY: RETAIN NYC PE AND ENDORSED CONTRACTOR TO INSPECT AND EVALUATE ENTIRE BUILDING AND PREPARE THE REPAIR DRAWINGS
ECB09/11/2020FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: OBSERVED AT EXP#2,LOOSE,SPALLING & MISSING CONCRETE AT VARIOUS LEVELS & LOCATIONS THROUGHOUT EXP#2. REMEDY: REPAIR & REPLACE.$3K due
DOB09/02/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/02/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/02/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/02/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB07/22/2020FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES AS NOTED AT TIME OF INSPECTION OBSERVED AT EXPOSURE#2 LOOSE STUCCO AT 2ND FLOOR THAT HAS FALLEN TO GROUND FLOOR AT ALLEY WAY THAT IS GATED ALSO AT FOURTH FLOO$2K due
DOB07/22/2020OBSERVED AT EXP.#1 A SECTION OF CONCRETE FACADE THAT HAS FALLEN FROM THE 4TH FLOOR ALSO EXP.#2 HAS DEFECTS TO FACADE WITH SPALLING AND FALLING FACADE IN ALLEY WAY
ECB03/27/2020FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: OBSERVED AT EXP#2 THE ARE CRACKS AT VARIOUS LOCATIONS,ALSO THE ARE MISSING CONCRETE EXPOSING THE REBARS. REMEDY: REPAIR &/OR REPLACE.$12K due
DOB03/04/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB01/30/2020FAILURE TO MAINTAIN IN BUILDING IN A CODE COMPLIANT AMNNER. @TIME OF INSPECTION @EXP#2 THERE IS FALLEN CRACKED AND/OR SPALLING CONCRETE @MULTIPLE AREAS.REM:REPAIR AND/OR REPLACE.$6K due
ECB12/20/2019FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER. OBSERVED IN 2ND FLOOR (LOFT) UNIT IN THE KIT AREA, THE BUILDING WALL EXPO # 3 LOOSE CONCRETE AROUND THE GAS LINE, AND PIECES FELL FROM THE UPPER HORIZONTAL$1K due
ECB12/19/2019TAMPERED WITH,REMOVED OR DEFACED A WRITTEN POSTED STOP WORK ORDER.NOTED:AT THE TIME OF INSPECTION OBSERVED PARTIAL STOP WORK ORDER WHICH WAS POSTED ON 12-12-2019 AT FRONT ENTRY DOOR WAS COMPLETLY REMOVED.REMEDY$2K due
ECB12/12/2019GAS SUPPLIED FURNACE INCLUDING DUCTWORK, GAS PIPES AND HARDWARE INSTALLED AT FIRST FLOOR. NO PLUMBING PERMIT ON FILE., OBTAIN PERMIT; STOP HEATERS INSTALLATION. MAKE SITE SAFE.$2K due
DOB09/06/2019VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
DOB05/30/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/15/2017VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST
DOB02/11/2015FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB02/11/2015FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB02/11/2015FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB02/11/2015FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB02/11/2015FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB02/11/2015FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB12/31/2014FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB12/31/2014FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB04/01/2002V-DOB VIOLATION - ACTIVE
DOB04/12/1993V-DOB VIOLATION - ACTIVE
ECB12/10/2020FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTE AT EXP#2 THE MASONRY FACADE IS IN REPAIR W/CRACKS,SPALLING & MISSING PIECES OF MASONRY & STUCCO THROUGHOUT. NO CERT OF CORRECTION IN BLDG DEPT RECORDS.Nothing owed — awaiting certificate of correction
ECB02/26/2018WORK WITHOUT A PERMIT. ON 02/26/18 @ APPROX 3:00PM. I OBSERVED ON THE 1ST, 3RD AND 5TH FLOOR THE CUTTING AND REMOVAL OF WATER, SANITARY AND GAS PIPING WITHOUT ANY PERMITS ON FILE. PARTIAL STOP WORK ORDER GIVEN.Nothing owed — awaiting certificate of correction
ECB11/10/2014UNLAWFUL ACTS. FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER.NOTE: VACATE ORDER #421/2014 ISSUED DUE TO THE LEGAL MANUFACTURING BUILDING IS ILLEGALLY CONVERTED THROUGHOUT INTO MUSIC,ARTIST STUDIOS AND RESINothing owed — awaiting certificate of correction
ECB11/07/2014OCCUPANCY CONTRARY TO THAT ALLOWED BY THE BLDG DEPT.RECORDS.BLDG DEPT RECORDS AS PER PERMITTED APPL.#300988386 SCHEDULE "A"INDICATES OFFICES AT 1ST FLR. FACTORY AT 2ND THRU 6TH FLRS. AT TIME OF INSPEC.OBSERVEDNothing owed — awaiting certificate of correction
ECB11/07/2014BC905.3.1 & NFPA 14 CH3.3.9 REQUIRED STANDPIPE SYSTEM NOT INSTALLED THROUGHOUT CELLAR TO STAIRWELL ALL THE WAY TO THE ROOF ARE MISSING ANDNOT IN PLACE. AFTER IT HAS EENCUT AWAY.RMDY: INSTALL STANDPIPE SYSTEM.Nothing owed — awaiting certificate of correction
ECB11/07/2014PIPING AND/OR EQUIPMENT INSTALLED IMPROPERLY AT 5TH FLR AT CEILING GASPIPE IS CONNECTED W/THE USE OF GAS FLEX'S AT 1ST FL A CEILING HEATING UNIT IS CONNECTED WITH SOLID PIPE.SAME AT HEATING UNIT WITH A GAS VALVNothing owed — awaiting certificate of correction
ECB11/03/2014PLUMBING WORK IN MANUFACTURING DISTRICT FOR RESIDENTIAL USE.NOTED:OBSERVED WATER,WASTE& GAS LINES ON 2ND FLR., CREATING 3PC BATHRM,KITCHEN,GAS STOVE & HEATERS.REMEDY:OBTAIN ALL REQUIRED PERMITS TO RESTORE PREMINothing owed — awaiting certificate of correction
ECB10/30/2014FAILURE TO MAINTAIN BLDG NOTED: ELEMENTS OF SPRINKER SYSTEM RUSTED, CORRODED, INOPERABLE. CELLAR FILLED W/ COMBUSTIBLE ITEMS OF VARIOUS KINDS & HINDERING ACCESS TO SPRINKER SYSTEM. HOLES IN CELLAR FL W/ POOLEDNothing owed — awaiting certificate of correction
ECB10/28/2014FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OFCORRECTION W/ THE DEPT. OF BLDG FOR NOTICE OF VIO. # 35107671Z ISSUED ON 09/29/14 PURSUANT TO 28-204.4 & 1RCNY 102-01. ALTERATION IN A MANUFNothing owed — awaiting certificate of correction
ECB09/29/2014SEC. 28-105.1 PLUMBING WORK IN MANUFACTURING DISTRICT FOR RESIDENTIAL USE. NOTED: OBSERVED WATER,WASTE & GAS LINES ON FLOORS 6,5,CREATING 3PC BATHROOMS,KITCHENS W/GAS STOVES & GAS HEATERS. PREMISES LOCATED INNothing owed — awaiting certificate of correction
ECB09/29/2014ALTERATION IN A MANUFACTURING DISTRICT FOR RESIDENTIAL USE. NOTED: PARTITION WALLS INSTALLED TO CREATE SLEEPING QUARTERS,LIVING ROOMS,KITCHENS & BATHROOMS ON FLOORS 6,5. PREMISES LOCATED IN M1-2 LIGHT MANUFACTUNothing owed — awaiting certificate of correction
ECB03/13/2000FAILURE TO MAINTAIN EXTERIOR BUILDING WALL LOOSE AND SPALLING CONCRETEAT FRONT WALL OF:LORIMER STREET:FROM 1ST TO 6 STORIES AT VARIOUS LOCATION.REMEDY:MAKE SAFE MAINTAIN EXTERIOR BUILDING WALL OBTAIN PERMIT'SNothing owed — awaiting certificate of correction