← Back
Two stories - detached, small or mid-size
79 OAKDALE STREET
STATEN ISLAND · Great Kills-Eltingville · BIN 5066346
💬 Discuss this project
1955Year Built
2Stories
A1Building Class
R3AZoning
1,296 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,610 sf lot · 0.36 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingCivilGeneral
Filed — no permit issued33p · 2 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STUDIO HUJI307/09/2024
Building Lifecycle
All (20)Filed (3)Objection (1)Special Inspection (16)
08/12/2024
Objection raised — Scope
07/09/2024
Filed — Alteration CO
APPLICATION FILED FOR NEW EAST DORMER AT ROOF AND INTERIOR RENOVATIONS AS PER PLAN AND TO LEGALIZE EXISTING WEST DORMER AND ROOF OVER FRONT PORCH
S01075829-I1
07/09/2024
Special inspection requirement — HVAC-R and service water heating equipment
07/09/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
07/09/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
07/09/2024
Special inspection requirement — HVAC-R and service water heating system controls
07/09/2024
Special inspection requirement — Mechanical Systems
07/09/2024
Special inspection requirement — Final
07/02/2024
Special inspection requirement — Fenestration areas
07/02/2024
Special inspection requirement — Air barrier - visual inspection
07/02/2024
Special inspection requirement — Insulation placement and R values
07/02/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/02/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
07/02/2024
Special inspection requirement — Energy Code Compliance Inspections
07/02/2024
Special inspection requirement — Maintenance information
07/02/2024
Special inspection requirement — Interior lighting power
07/02/2024
Special inspection requirement — Fire-Resistance Rated Construction
07/02/2024
Special inspection requirement — Structural Wood Frame
05/29/2024
Filed — Alteration
S01034780-S1
05/29/2024
Filed — Alteration
S01034780-I1
Nothing on file for this building.
1 project · most recent 07/09/2024
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/09/2024——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MUZ-EF25VG-A1 3 kW · Split System ×1
MXZ-5C42NA3 43,000 BTU · Split System ×1
Ventilation
Nutone HB80RL 80 CFM · Exhaust Fan ×1
1 project · most recent 07/09/2024
Wood
FiledStatusContractorScope
07/09/2024——Wood
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
07/09/2024HVAC-R and service water heating equipment—energy_progress
07/09/2024Structural Stability – Alterations of existing buildings—special
07/09/2024HVAC-R and service water piping design and insulation—energy_progress
07/09/2024HVAC-R and service water heating system controls—energy_progress
07/09/2024Mechanical Systems—special
07/09/2024Final—progress
07/02/2024Fenestration areas—energy_progress
07/02/2024Air barrier - visual inspection—energy_progress
07/02/2024Insulation placement and R values—energy_progress
07/02/2024Fire-Resistant Penetrations and Joints—special
07/02/2024Fenestration and door U-factor and product ratings—energy_progress
07/02/2024Energy Code Compliance Inspections—progress
07/02/2024Maintenance information—energy_progress
07/02/2024Interior lighting power—energy_progress
07/02/2024Fire-Resistance Rated Construction—progress
07/02/2024Structural Wood Frame—progress
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/21/2026S01034780-S1Request digital key ↗
08/21/2026S01034780-I1Request digital key ↗
08/15/2026S01075829-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026S01034780-I1Open ↗
08/13/2026S01075829-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026S01034780-I1Open ↗
08/13/2026S01075829-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S01075829-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/21/2026S01034780-S1Open ↗
08/21/2026S01034780-I1Open ↗
08/21/2026S01075829-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026S01075829-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/21/2026S01034780-S1Open ↗
08/21/2026S01034780-I1Open ↗
08/15/2026S01075829-I1Open ↗
▸Other Documents7
▸DOB NOWSite Survey: Initial2
08/13/2026S01034780-I1Open ↗
08/13/2026S01075829-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/15/2026S01075829-I1Open ↗
08/13/2026S01034780-I1Open ↗
▸DOB NOWPlot Diagram2
08/13/2026S01075829-I1Open ↗
08/13/2026S01034780-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/15/2026S01075829-I1Open ↗