← Back
BuildNYC
Unlicensed parking lot
Graffiti House
8-48 ASTORIA BOULEVARD · BIN 4541911
💬 Discuss this project
0Year Built
—Stories
G7Building Class
R6AZoning
—Gross Floor Area
0Units
1 Active Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Unlicensed parking lot · Owner of record: Cojam Construction · 0 FAR built · Flood zone X
Locations of Work
ArchitectureGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof1 filing · 7 docs
Floor 71 filing · 7 docs
Floor 61 filing · 7 docs
Floor 51 filing · 7 docs
Floor 41 filing · 7 docs
Floor 31 filing · 7 docs
Floor 21 filing · 7 docs
Floor 11 filing · 7 docs
Cellar1 filing · 7 docs
Filed — no permit issued8-48 Astoria10p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Cojam Construction103/22/2026
Cojam Realty103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Yaker Engineering110/01/2026
Versatile Engineering209/26/2026
Dome Archietcture, Design & Engineering109/09/2026
Building Lifecycle
All (25)Filed (4)Violation (3)Objection (3)Special Inspection (15)
10/02/2026
Objection raised — Other
10/01/2026
Filed — Full Demolition
8' PLYWOOD CONSTRUCTION FENCE DURING DEMOLITION WORK
Q01462069-I1
10/01/2026
Objection resolved — Resolved
09/28/2026
Objection raised — Other
09/26/2026
Filed — New Building
Sprinklers system throughout new 7-story monolithic concrete building
Q01450056-S4
09/26/2026
Special inspection requirement — Maintenance information
09/26/2026
Special inspection requirement — HVAC-R and service water heating system controls
09/26/2026
Special inspection requirement — Duct leakage testing, insulation and design
09/26/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
09/26/2026
Special inspection requirement — HVAC-R and service water heating equipment
09/26/2026
Special inspection requirement — Shutoff dampers
09/18/2026
Special inspection requirement — Structural Stability – Alterations of existing Buildings
09/18/2026
Special inspection requirement — Demolition
09/09/2026
Filed — New Building
Sprinklers system throughout new 7-story monolithic concrete building
Q01450056-S8
09/09/2026
Filed — New Building
Sprinklers system throughout new 7-story monolithic concrete building
Q01450056-I1
09/08/2026
Special inspection requirement — Fenestration areas
09/08/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
09/08/2026
Special inspection requirement — Fenestration air leakage
09/08/2026
Special inspection requirement — Air barrier - visual inspection
09/08/2026
Special inspection requirement — Insulation placement and R values
08/23/2026
Special inspection requirement — Final
08/23/2026
Special inspection requirement — Mechanical Systems
02/06/2016
Violation issued (ECB, closed)
Construction
05/18/2011
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
02/18/2011
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISPLISSUEDAriana Contracting04/09/2003
BIS—ISSUEDCojam Realty03/21/2003
BISEQISSUEDCojam Realty02/04/2003
BISEQISSUEDCojam Realty07/01/2002
1 project · most recent 09/26/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/26/2026——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MULTI V S R32 27,000 BTU · Condensing Unit ×26
Ventilation
Renewaire HE10-JRTV-S15AA-GNT-L 535 CFM · Erv ×1
1 project · most recent 09/26/2026
Storm Water/Sanitary
FiledStatusContractorScope
09/26/2026——Storm, Water/Sanitary
1 project · most recent 09/26/2026
Concrete
FiledStatusContractorScope
09/26/2026——Concrete
2 projects · most recent 10/01/2026
Fence
FiledStatusContractorScope
10/01/2026——Fence
09/26/2026——Fence
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
09/26/2026Maintenance information—energy_progress
09/26/2026HVAC-R and service water heating system controls—energy_progress
09/26/2026Duct leakage testing, insulation and design—energy_progress
09/26/2026HVAC-R and service water piping design and insulation—energy_progress
09/26/2026HVAC-R and service water heating equipment—energy_progress
09/26/2026Shutoff dampers—energy_progress
09/18/2026Structural Stability – Alterations of existing Buildings—special
09/18/2026Demolition—special
09/08/2026Fenestration areas—energy_progress
09/08/2026Fenestration and door U-factor and product ratings—energy_progress
09/08/2026Fenestration air leakage—energy_progress
09/08/2026Air barrier - visual inspection—energy_progress
09/08/2026Insulation placement and R values—energy_progress
08/23/2026Final—progress
08/23/2026Mechanical Systems—special
▾Tenants in the building
TenantSpaceFloorsRenovation projects
8-48 AstoriaParking—
Project Q01462069 Full Demolition · Plan Examiner Review · 10/01/2026
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
10/04/2026Q01450056-S4Request digital key ↗
10/04/2026Q01450056-S8Request digital key ↗
10/04/2026Q01462069-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
10/04/2026Q01450056-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature6
10/04/2026Q01450056-I1Open ↗
10/04/2026Q01450056-S1Open ↗
10/04/2026Q01450056-S8Open ↗
Showing 3 of 6 on file for this type
▸Other Documents2
▸DOB NOWStructure Photographs1
10/04/2026Q01462069-I1Open ↗
▸DOB NOWSite Survey: Initial1
10/04/2026Q01450056-I1Open ↗