← Back
BuildNYC
Two family converted from one family
8 REVERE PLACE
BROOKLYN · BIN 3030518
💬 Discuss this project
1897Year Built
2Stories
B3Building Class
R6Zoning
2,630 sfGross Floor Area
2Units
2 Active Violations ▸FDNY Report ↗
Two family converted from one family · 1,617 sf lot · 1.63 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 2Interior renovation, 3 story two family house10p · 3 filings · 20 docs
Floor 1Interior renovation, 3 story two family house5p · 3 filings · 20 docs
CellarInterior renovation, 3 story two family house9p · 3 filings · 20 docs
BasementInterior renovation, 3 story two family house4p · 2 filings · 20 docs
Sub-BasementPlumbing fixture replacement and installation3p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BH1003/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/08/2024$2.1M—BHNWN BROOKLYN LLC → Private party$798/sf building
09/18/2019$930K—Private party → BHNWN BROOKLYN LLC$354/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KNF Services Crop612/22/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RCGA Architects803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Deep FormationGeneral Contractor903/21/2026
Better Homes DepotGeneral Contractor103/21/2026
Plumbing P & HPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF Services5616612/22/2023
Building Lifecycle
09/25/2024
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
B00780630-I1-GC
03/22/2024
Signed off — Alteration
Propose to perform an interior renovation work at the basement, 1st and 2nd floor of 3 story -two family brick house. No change in use, egress and occupancy.
B00778986-I1
03/21/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/08/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
02/23/2024
Signed off — Alteration
Filing to remove gas raiser diagram as there was no gas in the building.
B00783814-I1
55 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedDeep Formation09/25/2023
DOB NOWPlumbingSigned-offPlumbing P & H10/20/2022
DOB NOWGeneral ConstructionSigned-offDeep Formation09/17/2022
DOB NOWGeneral ConstructionPermit IssuedDeep Formation09/17/2022
BIS—ISSUEDBetter Homes Depot04/20/2000
1 project · most recent 01/03/2024
General Wiring
FiledStatusContractorScope
01/03/2024CompleteRiviera ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
03/21/2024Pass-Final General Construction Non-Directive 14PassView ↗
03/08/2024Fail-Final General Construction Non-Directive 14FailView ↗
01/08/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/08/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/19/2023Pass-Final CND-Occupancy InspectionPassView ↗
10/03/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
12/18/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
12/18/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
11/20/2023Fenestration areasFAHAD FATEHenergy_progress
11/20/2023MasonryFAHAD FATEHspecial
11/20/2023Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
11/20/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
11/20/2023Fire-Resistance Rated ConstructionFAHAD FATEHprogress
11/20/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
11/20/2023Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
11/20/2023Air barrier - visual inspectionFAHAD FATEHenergy_progress
11/20/2023Lighting in dwelling unitsFAHAD FATEHenergy_progress
11/20/2023Fenestration air leakageFAHAD FATEHenergy_progress
11/20/2023Interior lighting powerFAHAD FATEHenergy_progress
11/09/2023Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
11/09/2023Fenestration air leakageFAHAD FATEHenergy_progress
11/09/2023Interior lighting powerFAHAD FATEHenergy_progress
11/09/2023Lighting in dwelling unitsFAHAD FATEHenergy_progress
11/09/2023Air barrier - visual inspectionFAHAD FATEHenergy_progress
11/09/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
11/09/2023MasonryFAHAD FATEHspecial
11/09/2023Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
11/09/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
11/09/2023Fire-Resistance Rated ConstructionFAHAD FATEHprogress
11/09/2023Fenestration areasFAHAD FATEHenergy_progress
11/25/2022Energy Code Compliance InspectionsFAHAD FATEHprogress
Latest 25 of 34.
41 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account