← Back
Two family converted from one family
80-60 57 STREET
QUEENS · Glendale · BIN 4434973
💬 Discuss this project
1910Year Built
1Stories
B3Building Class
R4-1Zoning
720 sfGross Floor Area
2Units
22 Open Violations 13 unresolved · 9 paperwork only ▸FDNY Report ↗
Two family converted from one family · Owner of record: CAM REAL ESTATE XIA, LLC · 2,160 sf lot · 0.33 FAR built · Flood zone X
Locations of Work
Architecture
Cellar2p · 2 filings · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/07/2023$678K—Private party → CAM REAL ESTATE XIA, LLC$942/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MALCOLM BARKAN207/07/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
4444 PPPP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
XH&RC PLBG AND HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MARKANICS CORP4600207/07/2021
Building Lifecycle
All (40)Filed (2)Permit Issued (1)Violation (34)Inspection (1)Special Inspection (2)
11/10/2021
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/25/2021
Permit issued — Plumbing
Q00541098-I1-PL
07/07/2021
Filed — Alteration
Q00541103-I1
07/07/2021
Filed — Alteration
propose to provide plumbing plans for cellar to restore to prior legal conditions .Plumbing work for cellar to cap and remove plumbing fixtures and gas fixtures only. propose work to comply with ecb violations
Q00541098-I1
06/15/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Malcolm Barkan
06/15/2021
Special inspection requirement — Energy Code Compliance Inspections
Malcolm Barkan
10/03/2020
Violation issued (HPD, open)
C
10/03/2020
Violation issued (HPD, open)
B
10/03/2020
Violation issued (HPD, open)
B
10/03/2020
Violation issued (HPD, open)
B
06/27/2020
Violation issued (HPD, open)
C
06/27/2020
Violation issued (HPD, open)
B
06/27/2020
Violation issued (HPD, open)
B
06/27/2020
Violation issued (HPD, open)
B
06/08/2020
Violation issued (HPD, open)
I
06/05/2020
Violation issued (HPD, open)
B
06/05/2020
Violation issued (HPD, open)
B
06/05/2020
Violation issued (HPD, closed)
C
10/16/2013
Violation issued (ECB, open)
Construction
08/12/2013
Violation issued (ECB, open)
Construction
06/06/2013
Violation issued (ECB, open)
Construction
04/12/2013
Violation issued (ECB, open)
Construction
02/12/2013
Violation issued (ECB, open)
Construction
12/08/2012
Violation issued (ECB, closed)
Construction
10/02/2012
Violation issued (ECB, closed)
Construction
08/04/2012
Violation issued (ECB, open)
Construction
06/05/2012
Violation issued (ECB, open)
Construction
05/18/2012
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/11/2012
Violation issued (ECB, closed)
Construction
02/17/2012
Violation issued (ECB, open)
Quality of Life
02/15/2012
Violation issued (ECB, open)
Construction
08/13/2008
Violation issued (HPD, open)
C
02/27/2006
Violation issued (ECB, closed)
Construction
02/21/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/28/2005
Violation issued (ECB, closed)
Construction
07/28/2005
Violation issued (ECB, closed)
Construction
07/28/2005
Violation issued (ECB, closed)
Construction
08/02/2004
Violation issued (ECB, closed)
Construction
09/24/2001
Violation issued (ECB, closed)
Zoning
09/24/2001
Violation issued (ECB, closed)
Zoning
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offXH&RC PLBG AND HTG INC10/25/2021
BISPLISSUEDROOTER PLUS, INC05/11/2006
BISOTISSUEDJD HOME IMPROVEMENT CORP01/25/2006
BISOTISSUEDN/A08/02/2005
BIS—ISSUEDN/A12/10/2004
1 project · most recent 07/07/2021
Gas Water/Sanitary
FiledStatusContractorScope
07/07/2021Signed-offXH&RC PLBG AND HTG INCGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
11/10/2021Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
06/15/2021Fire-Resistant Penetrations and JointsMalcolm Barkanspecial
06/15/2021Energy Code Compliance InspectionsMalcolm Barkanprogress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026Q00541103-I1Request digital key ↗
08/27/2026Q00541098-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/27/2026Q00541098-I1Open ↗
08/13/2026Q00541103-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/27/2026Q00541098-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026Q00541098-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/27/2026Q00541098-I1Open ↗
08/13/2026Q00541103-I1Open ↗