| Owner | Filings | Most Recent |
|---|---|---|
| JERRICK ASSOCIATES | 13 | 07/08/2026 |
| DUPONT ASSOCIATES | 13 | 03/22/2026 |
| SOLIL MANAGEMENT | 7 | 03/22/2026 |
| DUPONT ASSOCS. INC. | 9 | 03/22/2026 |
| 80 CRANBERRY STREET | 40 | 03/22/2026 |
| TO THE OF 80 CRANBEERY ST | 1 | 03/22/2026 |
| TO THE OWNER OF 80 CRANBE | 1 | 03/22/2026 |
| OWNER OF THE PREMISES | 1 | 03/22/2026 |
| TO THE OWNER OF THE PREMI | 1 | 03/22/2026 |
| CERONE EXTERIOR REST CORP | 1 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| SOTIR ASSOCIATES | 2 | 08/16/2024 |
| PAUL PERDEK, PROF. ENG. PLLC | 1 | 05/22/2024 |
| MJ ENGINEERING & DESIGN | 2 | 03/28/2024 |
| ASIF JAMIL, RA | 1 | 02/28/2020 |
| BAILEYS ENGINEERING PC | 1 | 02/27/2019 |
| Representative | Filings | Most Recent |
|---|---|---|
| MUNICIPAL BUILDING CONSULTANTS | 1 | 03/21/2026 |
| AE DESIGN SOLUTION | 4 | 03/21/2026 |
| SOTIR ASSOCIATES | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| AL SAEED CONSTRUCTION | General Contractor | 7 | 04/09/2026 |
| JERRICK ASSOCIATES INC | General Contractor | 5 | 07/08/2026 |
| FOTAKOS, GEORGE | Electrical | 4 | 03/21/2026 |
| TORAL WELDING INC | Electrical | 4 | 03/21/2026 |
| DPH PLUMBING & HTG CORP | Plumbing | 2 | 07/08/2026 |
| JOHNNY'S P&H CONTRAC INC | Plumbing | 1 | 07/08/2026 |
| KIM MICHAEL | Electrical | 1 | 03/21/2026 |
| MICHAEL KIM | Electrical | 1 | 03/21/2026 |
| BOROWIDE ELECT'L CONTR'S | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| SOTIR ASSOCIATES | 7473 | 4 | 08/16/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | DPH PLUMBING & HTG CORP | 01/09/2026 |
| DOB NOW | Plumbing | Signed-off | DPH PLUMBING & HTG CORP | 10/28/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | AL SAEED CONSTRUCTION | 07/25/2024 |
| DOB NOW | Sidewalk Shed | Signed-off | GE 2A CONSTRUCTION | 05/23/2024 |
| DOB NOW | General Construction | Permit Issued | AL SAEED CONSTRUCTION | 04/19/2024 |
| DOB NOW | General Construction | Signed-off | AL SAEED CONSTRUCTION | 04/05/2024 |
| DOB NOW | Sidewalk Shed | Permit Issued | GE 2A CONSTRUCTION | 03/17/2020 |
| DOB NOW | Plumbing | Signed-off | JOHNNY NANHU | 03/06/2020 |
| DOB NOW | Sidewalk Shed | Permit Issued | GE 2A CONSTRUCTION | 03/03/2020 |
| DOB NOW | Sidewalk Shed | Permit Issued | GE 2A CONSTRUCTION | 02/28/2019 |
| BIS | OT | ISSUED | ALL CITY REMODELING, INC | 06/23/2020 |
| BIS | OT | ISSUED | ALL CITY REMODELING, INC | 03/06/2020 |
| BIS | OT | ISSUED | SUPER POWER CONSTRUCTION | 01/29/2019 |
| BIS | FP | ISSUED | PINNACLE PLBG & HTG CORP | 11/08/2018 |
| BIS | OT | ISSUED | SUPER POWER CONSTRUCTION | 09/25/2018 |
| BIS | PL | ISSUED | TRI STATE PLBG & HTG INC | 09/25/2018 |
| BIS | OT | ISSUED | ALL CITY REMODELING, INC | 05/09/2018 |
| BIS | OT | ISSUED | ALL CITY REMODELING, INC | 02/06/2018 |
| BIS | OT | ISSUED | LAUNDRO COMBUSTION CORP | 02/02/2017 |
| BIS | PL | ISSUED | TOP DOG PLBG & HTG CORP | 03/22/2016 |
| BIS | OT | ISSUED | KING'S USA GROUP INC | 02/23/2016 |
| BIS | EQ | ISSUED | JERRICK ASSOCIATES INC | 12/07/2012 |
| BIS | PL | ISSUED | HIGHLAND PLUMBING LLC | 05/02/2012 |
| BIS | MH | ISSUED | BAIS CONTRACTORS INC | 04/24/2012 |
| BIS | FP | ISSUED | MASTER FIRE SYSTEMS, INC | 09/09/2011 |
| BIS | OT | ISSUED | CERCONE EXTERIOR REST COR | 07/06/2011 |
| BIS | EQ | ISSUED | SUKHMANY CONSTRUCTION INC | 05/31/2011 |
| BIS | OT | ISSUED | KING'S USA GROUP INC | 05/13/2011 |
| BIS | OT | ISSUED | ALL CITY REMODELING, INC | 03/21/2011 |
| BIS | MH | ISSUED | ALL CITY REMODELING, INC | 03/21/2011 |
| BIS | OT | ISSUED | ALL CITY REMODELING, INC | 03/10/2011 |
| BIS | MH | ISSUED | ALL CITY REMODELING, INC | 03/07/2011 |
| BIS | MH | ISSUED | KING'S ASSOCIATES, INC | 02/16/2011 |
| BIS | PL | ISSUED | THE PLUMBING COMPANY INC | 02/15/2011 |
| BIS | OT | ISSUED | KING'S ASSOCIATES, INC | 02/02/2011 |
| BIS | EQ | ISSUED | CERCONE EXTERIOR REST COR | 10/01/2010 |
| BIS | OT | ISSUED | CERCONE EXTERIOR REST COR | 09/08/2010 |
| BIS | EQ | ISSUED | JERRICK ASSOCIATES INC | 11/12/2008 |
| BIS | OT | ISSUED | ALL CITY REMODELING, INC | 04/02/2008 |
| BIS | OT | ISSUED | ALL CITY REMODELING, INC | 06/29/2007 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/16/2024 | Permit Issued | AL SAEED CONSTRUCTION | Refrigeration Systems, Ventilation Systems | Ventilation Captiveaire NCA18FA 5,500 CFM · Kitchen Exhaust ×2 Greenheck BSQ-240 5,500 CFM · Makeup Air ×2 Refrigeration Copeland XFAL 040Z TFC 081 29,610 BTU · Condensing Unit ×1 XFAL 050Z TFC 081 32,880 BTU · Condensing Unit ×1 XFAM 060Z TFC 081 53,500 BTU · Condensing Unit ×1 Trenton TEZA008H8-HT3D-B 32,880 BTU · Refrigeration Unit ×1 TEZA011H8-HT3D-B 29,610 BTU · Refrigeration Unit ×1 TEZA025L8-HT3D-F 53,500 BTU · Refrigeration Unit ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/28/2024 | Signed-off | JMW PLUMBING, INC | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/26/2019 | Complete | BOROWIDE ELECT'L CONTR'S | — |
| 11/27/2018 | Complete | A.C. MORGAN ELECTRIC | General Wiring, Lighting |
| Date | Type | Result | Report |
|---|---|---|---|
| 01/30/2026 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 01/30/2026 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 01/15/2026 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 01/14/2026 | Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish | Certified | View ↗ |
| 01/12/2026 | Certified Sprinkler (PL)-Sprinkler-Hydro | Certified | View ↗ |
| 01/14/2025 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 11/08/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 09/16/2024 | Energy Code Compliance Inspections | Hany Demetry | progress |
| 09/16/2024 | Mechanical Systems | Hany Demetry | special |
| 09/16/2024 | Structural Stability – Alterations of existing buildings | Hany Demetry | special |
| 09/16/2024 | Fire-Resistant Penetrations and Joints | Hany Demetry | special |
| 09/16/2024 | HVAC-R and service water heating equipment | Hany Demetry | energy_progress |
| 09/16/2024 | Final | Hany Demetry | progress |
| 09/16/2024 | Post-installed Anchors | Hany Demetry | special |
| 09/16/2024 | Tenant Protection Plan Compliance | Hany Demetry | special |
| 08/16/2024 | Energy Code Compliance Inspections | Hany Demetry | progress |
| 08/16/2024 | Fire-Resistant Penetrations and Joints | Hany Demetry | special |
| 08/16/2024 | Mechanical Systems | Hany Demetry | special |
| 08/16/2024 | Post-installed Anchors | Hany Demetry | special |
| 08/16/2024 | Structural Stability – Alterations of existing buildings | Hany Demetry | special |
| 08/16/2024 | Tenant Protection Plan Compliance | Hany Demetry | special |
| 08/16/2024 | Final | Hany Demetry | progress |
| 08/16/2024 | HVAC-R and service water heating equipment | Hany Demetry | energy_progress |
| 03/26/2024 | Tenant Protection Plan Compliance | Hany Demetry | special |
| 03/26/2024 | Energy Code Compliance Inspections | Hany Demetry | progress |
| 03/26/2024 | Tenant Protection Plan Compliance | Hany Demetry | special |
| 03/26/2024 | Structural Stability – Alterations of existing buildings | Hany Demetry | special |
| 03/26/2024 | Fire-Resistant Penetrations and Joints | Hany Demetry | special |
| 03/26/2024 | Energy Code Compliance Inspections | Hany Demetry | progress |