ECB10/10/2026Failure to maintain parking structure in safe condition. As noted at of inspection on an active occupied parking structure consisting of 6 levels, observed at exposure #3(south elevation) vertical crack at bulk$2K due
ECB05/27/2022Failure to maintain building. At time of inspection observed at south side of pre-fab parking structure at 1ST thru 3RD severe corrosion to concrete ceiling slab where sections of concrete have detached exposin$25K due
Old · issued 3+ years ago and still listed by DOB; nothing on the city's records either way
DOB05/27/2022Structure rendered non-compliant. At time of inspection minor damage observed to have been sustained to 1ST thru 3RD consisting of glass block windows, scorching of ceiling. Multiple vehicles damaged.Issued 2022; DOB's record still lists it as active
DOB05/27/2022Failure to maintain building. At time of insp observed at south side of parking structure at 1ST thru 3RD severe corrosion to concrete ceiling slab where sections have detached exposing steel re-bar. Severe horizontal/vertical cracks where water has penetrated compromising structural stability. Multiple areas shows severe signsIssued 2022; DOB's record still lists it as active
DOB05/27/2022Emerg wrk-fire occured-2FL ramp sw corner effecting strctr above- 6 bays approx 100'X50' incld 3 cantilevered areas&3 back spans crackd concrt ribs & exposed rebar.3FL slab struct comprmsd.overhd haz ownr immed retain nyspe&contrctr-eval compromisd structr & desgn&instl temp shorng/stblilztn.pe sbmt mean/method to feu by 5/31/22Issued 2022; DOB's record still lists it as active
DOB05/27/2022Ftm-fire on 5/27/22 on 2FL affecting strcture abv for ~6BAYS including 3 canted bays & 3 backspans.unrelatd to fire-spalling concrt @spandrel on ramp & @undrside of slabs,crckd slabs,mild-modrate water-infiltratn thru slab.ownr immed retain nyspe&contrctr-eval entire structr &prform rprs undr prmt.file by 7/1/22,begin by 8/1/22,cmplt 8/1/23Issued 2022; DOB's record still lists it as active