← Back
Two family converted from one family
8005 13 AVENUE
BROOKLYN · BIN 3163043
💬 Discuss this project
1910Year Built
2.75Stories
B3Building Class
R5BZoning
3,875 sfGross Floor Area
2Units
Two family converted from one family · Owner of record: 8005 LLC · 6,000 sf lot · 0.65 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 3Under Construction20p · 1 filing · 20 docs
Floor 2Under Construction17p · 1 filing · 20 docs
Floor 1Under Construction17p · 1 filing · 20 docs
CellarUnder Construction17p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BAY 341109/14/2026
8005 LLC203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/20/2020$2.2M—— → —$575/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
S M TAM ARCHITECT, PLLC709/10/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HTC CONSTRUCTION MANAGEMENTGeneral Contractor104/09/2026
ARCO PLBG AND HTG INCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD TESTING & INSPECTION S7010609/10/2026
Building Lifecycle
All (50)Filed (7)Permit Issued (2)Inspection (9)Objection (2)Special Inspection (30)
09/10/2026
Filed — Alteration
PROPOSED PLUMBING WORK AT CELLAR TO 3RD FLOOR AS PER PLAN.
B01266803-P4
09/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
09/10/2026
Special inspection requirement — Maintenance information
XIUCHENG LI
09/10/2026
Special inspection requirement — HVAC-R and service water heating equipment
XIUCHENG LI
09/10/2026
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
09/10/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
XIUCHENG LI
09/10/2026
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
08/25/2026
Filed — Alteration
PROPOSED PLUMBING WORK AT CELLAR TO 3RD FLOOR AS PER PLAN.
B01266803-P3
08/25/2026
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
08/25/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
08/25/2026
Special inspection requirement — Insulation placement and R values
XIUCHENG LI
08/25/2026
Special inspection requirement — Air barrier - visual inspection
XIUCHENG LI
08/25/2026
Special inspection requirement — Interior lighting power
XIUCHENG LI
08/25/2026
Special inspection requirement — Fire-Resistance Rated Construction
XIUCHENG LI
08/25/2026
Special inspection requirement — Final
XIUCHENG LI
08/19/2026
Filed — Alteration
PROPOSED PLUMBING WORK AT CELLAR TO 3RD FLOOR AS PER PLAN.
B01266803-S2
08/13/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/10/2026
Special inspection requirement — Mechanical Systems
08/10/2026
Special inspection requirement — Final
08/10/2026
Special inspection requirement — Energy Code Compliance Inspections
08/10/2026
Special inspection requirement — HVAC-R and service water heating system controls
08/10/2026
Special inspection requirement — Maintenance information
08/10/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
08/10/2026
Special inspection requirement — HVAC-R and service water heating equipment
06/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
06/22/2026
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
06/22/2026
Special inspection requirement — HVAC-R and service water heating equipment
XIUCHENG LI
06/22/2026
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
06/22/2026
Special inspection requirement — Maintenance information
XIUCHENG LI
06/22/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
XIUCHENG LI
06/08/2026
Objection resolved — Addressed
06/05/2026
Objection raised — Other
05/27/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/21/2026
Filed — Alteration
PROPOSED PLUMBING WORK AT CELLAR TO 3RD FLOOR AS PER PLAN.
B01266803-P2
05/21/2026
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
05/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIUCHENG LI
05/21/2026
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
05/21/2026
Special inspection requirement — Maintenance information
XIUCHENG LI
04/21/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/15/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/19/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/13/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/13/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/13/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/10/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/09/2026
Permit issued — Plumbing
B01266803-S1-PL
02/25/2026
Filed — Alteration
PROPOSED PLUMBING WORK AT CELLAR TO 3RD FLOOR AS PER PLAN.
B01266803-S1
02/05/2026
Filed — Alteration
PROPOSED PLUMBING WORK AT CELLAR TO 3RD FLOOR AS PER PLAN.
B01266803-P1
10/31/2025
Permit issued — General Construction
B01266803-I1-GC
09/17/2025
Filed — Alteration
PROPOSED PLUMBING WORK AT CELLAR TO 3RD FLOOR AS PER PLAN.
B01266803-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedARCO PLBG AND HTG INC03/09/2026
DOB NOWGeneral ConstructionPermit IssuedHTC CONSTRUCTION MANAGEME10/31/2025
1 project · most recent 09/10/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/10/2026Permit IssuedHTC CONSTRUCTION MANAGEMEHeating and Air Conditioning Systems
Heat / Cool
Gree LIV09HP230VIR32AH 9,100 BTU · Split System ×29
MUL24HP230V1R32AO 24,000 BTU · Condensing Unit ×8
MUL18HP230V1R32AO 18,000 BTU · Condensing Unit ×4
1 project · most recent 09/10/2026
Gas Water/Sanitary
FiledStatusContractorScope
09/10/2026Permit IssuedARCO PLBG AND HTG INCGas, Water/Sanitary
1 project · most recent 09/20/2025
General Wiring
FiledStatusContractorScope
09/20/2025Permit IssuedW 8 ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
08/13/2026Pass-Final CND-Occupancy InspectionPassView ↗
05/27/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/21/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/15/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/19/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/13/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/13/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/13/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/10/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 46
DateRequirementInspectorRole
09/10/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
09/10/2026Maintenance informationXIUCHENG LIenergy_progress
09/10/2026HVAC-R and service water heating equipmentXIUCHENG LIenergy_progress
09/10/2026HVAC-R and service water heating system controlsXIUCHENG LIenergy_progress
09/10/2026HVAC-R and service water piping design and insulationXIUCHENG LIenergy_progress
09/10/2026Energy Code Compliance InspectionsXIUCHENG LIprogress
08/25/2026Energy Code Compliance InspectionsXIUCHENG LIprogress
08/25/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
08/25/2026Insulation placement and R valuesXIUCHENG LIenergy_progress
08/25/2026Air barrier - visual inspectionXIUCHENG LIenergy_progress
08/25/2026Interior lighting powerXIUCHENG LIenergy_progress
08/25/2026Fire-Resistance Rated ConstructionXIUCHENG LIprogress
08/25/2026FinalXIUCHENG LIprogress
08/10/2026Mechanical Systems—special
08/10/2026Final—progress
08/10/2026Energy Code Compliance Inspections—progress
08/10/2026HVAC-R and service water heating system controls—energy_progress
08/10/2026Maintenance information—energy_progress
08/10/2026HVAC-R and service water piping design and insulation—energy_progress
08/10/2026HVAC-R and service water heating equipment—energy_progress
06/22/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
06/22/2026Energy Code Compliance InspectionsXIUCHENG LIprogress
06/22/2026HVAC-R and service water heating equipmentXIUCHENG LIenergy_progress
06/22/2026HVAC-R and service water heating system controlsXIUCHENG LIenergy_progress
06/22/2026Maintenance informationXIUCHENG LIenergy_progress
Latest 25 of 46.
▾Documents — 55 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/20/2026B01266803-S2Request digital key ↗
08/16/2026B01266803-P1Request digital key ↗
08/16/2026B01266803-S1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
08/14/2025322120575Open ↗
▸Zoning, Tax Lot & Property Records4
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
12/05/2025322120575Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
12/05/2025322120575Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
12/05/2025322120575Open ↗
▸DOB NOWRestrictive Declaration/Easement 11
09/15/2026B01266803-P4Open ↗
▸Seals & Professional Certifications25
▸DOB NOWProgress Inspector Seal & Signature12
09/23/2026B01266803-P3Open ↗
09/23/2026B01266803-P4Open ↗
09/23/2026B01266803-P4Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
09/15/2026B01266803-P4Open ↗
08/20/2026B01266803-S2Open ↗
08/16/2026B01266803-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/23/2026B01266803-P4Open ↗
09/23/2026B01266803-P3Open ↗
08/29/2026B01266803-P2Open ↗
Showing 3 of 6 on file for this type
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
09/15/2026B01266803-P4Open ↗
08/20/2026B01266803-S2Open ↗
08/16/2026B01266803-P1Open ↗
Showing 3 of 7 on file for this type
▸Approvals, Objections & Sign-offs5
▸BISLETTERS - SUPPORTING DOCUMENTATION5
12/05/2025322120575Open ↗
12/05/2025322120575Open ↗
12/05/2025322120575Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
08/14/2025322120575Open ↗
09/16/2021322100141Open ↗
▸Other Documents5
▸BISPLOT DIAGRAM4
12/05/2025322120575Open ↗
12/05/2025322120575Open ↗
08/25/2025322120575Open ↗
Showing 3 of 4 on file for this type
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
12/05/2025322120575Open ↗