| Owner | Filings | Most Recent |
|---|---|---|
| 730 BROADWAY SONIC | 21 | 07/08/2026 |
| 805 PENNSYLVANIA AVENUE | 12 | 03/21/2026 |
| RENAISSANCE REALTY GROUP | 8 | 07/08/2026 |
| 1701 UTICA AVE | 2 | 03/21/2026 |
| DANNYS | 1 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| JUST CONSULTING ENGINEERING | 2 | 05/30/2025 |
| RICHARD WAINER ARCHITECT, PLLC | 3 | 05/22/2024 |
| LAWRENCE MAREK ARCHITECT | 4 | 03/28/2024 |
| CHERICO KING ARCHITECT, P.C. | 1 | 03/16/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| D R BROWN | 6 | 03/21/2026 |
| CHERICO KING ARCHITECT P C | 13 | 03/21/2026 |
| CHERICO KING ARCHITECT P.C. | 1 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| CENTAURI DEVELOPMENT INC | General Contractor | 5 | 07/08/2026 |
| TEE BEE SIGN INST | Scaffold | 3 | 07/08/2026 |
| HP SERVICES INC | Plumbing | 2 | 07/08/2026 |
| AURORA ELECL CONTG INC | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| JUST CONSULTING ENGINEERI | 5865 | 2 | 05/30/2025 |
| CHERICO KING ARCHITECT PC | 5674 | 4 | 03/28/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Permit Issued | HP SERVICES INC | 04/04/2025 |
| DOB NOW | Sign | Signed-off | WEINFELD, ELLIOT | 05/29/2024 |
| DOB NOW | Sign | Signed-off | WEINFELD, ELLIOT | 05/29/2024 |
| DOB NOW | Sign | Signed-off | WEINFELD, ELLIOT | 05/29/2024 |
| DOB NOW | Construction Fence | Permit Issued | CENTAURI DEVELOPMENT INC | 04/01/2024 |
| DOB NOW | Plumbing | Permit Issued | HP SERVICES INC | 03/26/2024 |
| DOB NOW | Structural | Signed-off | CENTAURI DEVELOPMENT INC | 02/22/2024 |
| DOB NOW | General Construction | Permit Issued | CENTAURI DEVELOPMENT INC | 01/10/2024 |
| BIS | FP | ISSUED | RELIABLE FIRE PROT. INC | 03/18/2016 |
| BIS | FP | ISSUED | RELIABLE FIRE PROT. INC | 09/30/2015 |
| BIS | PL | ISSUED | ARIANA CONTRACTING INC | 12/18/2014 |
| BIS | FP | ISSUED | RELIABLE FIRE PROT. INC | 10/29/2014 |
| BIS | PL | ISSUED | ARIANA CONTRACTING INC | 10/24/2014 |
| BIS | EQ | ISSUED | THE BMC GROUP CONSULTING | 09/30/2014 |
| BIS | MH | ISSUED | THE BMC GROUP CONSULTING | 09/30/2014 |
| BIS | SP | ISSUED | SAFETY FIRE SPRINKLER CORP | 06/16/2014 |
| BIS | OT | ISSUED | YCK CONTRACTING CORP | 05/29/2014 |
| BIS | EQ | ISSUED | YCK CONTRACTING CORP | 05/29/2014 |
| BIS | — | ISSUED | YCK CONTRACTING CORP | 05/29/2014 |
| BIS | EQ | ISSUED | YCK CONTRACTING CORP | 01/16/2014 |
| BIS | PL | ISSUED | MMI PLUMBING & HEATING INC. | 01/07/2014 |
| BIS | OT | ISSUED | YCK CONTRACTING CORP | 12/31/2013 |
| BIS | — | ISSUED | YCK CONTRACTING CORP | 12/02/2013 |
| BIS | OT | ISSUED | TOWNHOUSE BUILDERS INC | 08/01/2013 |
| BIS | PL | ISSUED | SKILLMAN PLG HTNG | 02/15/2000 |
| BIS | FP | ISSUED | LUND FIRE PROD | 09/08/1999 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/30/2025 | Signed-off | CENTAURI DEVELOPMENT INC | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Trane RELOCATE EXISTING RTU, EUP#: 320942575 (NO CHANGE) 120,000 BTU · Rooftop Unit ×2 Ventilation Captiveaire 4224 ND-2-PSP-F 2,100 CFM · Kitchen Exhaust ×2 |
| 03/16/2024 | — | — | Ventilation Systems | Ventilation Captiveaire ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/30/2025 | Permit Issued | HP SERVICES INC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/16/2024 | Permit Issued | AURORA ELECL CONTG INC | — |
| 06/16/2024 | Permit Issued | AURORA ELECL CONTG INC | — |
| 06/16/2024 | Permit Issued | AURORA ELECL CONTG INC | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/30/2025 | Permit Issued | HP SERVICES INC | Steel |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/07/2024 | Permit Issued | CENTAURI DEVELOPMENT INC | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 04/01/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 12/01/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 04/04/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 03/21/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 11/14/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/06/2024 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 04/12/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 06/10/2025 | Sprayed fire-resistant materials | XIAOJUN WANG | special |
| 06/10/2025 | Structural Steel - Welding | XIAOJUN WANG | special |
| 06/10/2025 | Final | CALVIN TRAN | progress |
| 06/10/2025 | Structural Stability – Alterations of existing buildings | XIAOJUN WANG | special |
| 06/10/2025 | Structural Steel - High Strength Bolting | XIAOJUN WANG | special |
| 06/10/2025 | Concrete - Cast-In-Place | XIAOJUN WANG | special |
| 06/10/2025 | Structural Steel - Details | XIAOJUN WANG | special |
| 05/03/2024 | Final | Richard Wainer | progress |
| 03/28/2024 | Lighting controls | LAWRENCE MAREK | energy_progress |
| 03/28/2024 | Structural Stability – Alterations of existing buildings | LAWRENCE MAREK | special |
| 03/28/2024 | Fire-Resistant Penetrations and Joints | LAWRENCE MAREK | special |
| 03/28/2024 | Energy Code Compliance Inspections | LAWRENCE MAREK | progress |
| 03/28/2024 | Final | LAWRENCE MAREK | progress |
| 03/28/2024 | Fire-Resistance Rated Construction | LAWRENCE MAREK | progress |
| 03/28/2024 | Fenestration areas | LAWRENCE MAREK | energy_progress |
| 03/28/2024 | Maintenance information | LAWRENCE MAREK | energy_progress |
| 03/28/2024 | HVAC-R and service water heating equipment | LAWRENCE MAREK | energy_progress |
| 03/28/2024 | Duct leakage testing, insulation and design | LAWRENCE MAREK | energy_progress |
| 03/28/2024 | Shutoff dampers | LAWRENCE MAREK | energy_progress |
| 03/28/2024 | HVAC-R and service water heating system controls | LAWRENCE MAREK | energy_progress |
| 03/28/2024 | Interior lighting power | LAWRENCE MAREK | energy_progress |
| 03/28/2024 | Air barrier - visual inspection | LAWRENCE MAREK | energy_progress |
| 03/28/2024 | HVAC-R and service water piping design and insulation | LAWRENCE MAREK | energy_progress |
| 03/28/2024 | Insulation placement and R values | LAWRENCE MAREK | energy_progress |
| 03/28/2024 | Protection of exposed foundation insulation | LAWRENCE MAREK | energy_progress |