← Back
One family attached or semi-detached
81-10 PENELOPE AVENUE
QUEENS · Middle Village · BIN 4600515
💬 Discuss this project
1940Year Built
2Stories
A5Building Class
R4BZoning
2,210 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One family attached or semi-detached · 1,953 sf lot · 1.13 FAR built · Flood zone X
Locations of Work
Structural
Floor 11 filing · 19 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/13/2021$900K—— → —$407/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FRANK PETRUSO ARCHITECT PC104/22/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&L CONSTRUCTION DEVELOPGeneral Contractor704/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MEHDI GHAZI, P.E. P.C.7129104/22/2022
Building Lifecycle
All (17)Filed (1)Permit Issued (3)Inspection (3)Special Inspection (10)
12/18/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/04/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/05/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/27/2023
Permit issued — Structural
Q00723901-I1-GC
12/22/2023
Permit issued — Earth Work
Q00723901-I1-ST
12/22/2023
Permit issued — Foundation
Q00723901-I1-FO-EA
04/22/2022
Filed — New Building
Q00723901-I1
04/22/2022
Special inspection requirement — Masonry
MEHDI GHAZI
04/22/2022
Special inspection requirement — Concrete - Cast-In-Place
MEHDI GHAZI
04/22/2022
Special inspection requirement — Final
MEHDI GHAZI
04/22/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
MEHDI GHAZI
04/22/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
ELIAS RASABI
04/22/2022
Special inspection requirement — Energy Code Compliance Inspections
MEHDI GHAZI
04/22/2022
Special inspection requirement — Fire-Resistance Rated Construction
MEHDI GHAZI
04/22/2022
Special inspection requirement — Structural Wood Frame
MEHDI GHAZI
04/22/2022
Special inspection requirement — Footing and Foundation
MEHDI GHAZI
04/22/2022
Special inspection requirement — Electric vehicle service equipment requirements
MEHDI GHAZI
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedL&L CONSTRUCTION DEVELOP12/27/2023
DOB NOWEarth WorkSigned-offL&L CONSTRUCTION DEVELOP12/22/2023
DOB NOWFoundationSigned-offL&L CONSTRUCTION DEVELOP12/22/2023
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
12/18/2024Pass-Final CND-Occupancy InspectionPassView ↗
04/04/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/05/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
04/22/2022MasonryMEHDI GHAZIspecial
04/22/2022Concrete - Cast-In-PlaceMEHDI GHAZIspecial
04/22/2022FinalMEHDI GHAZIprogress
04/22/2022Fire-Resistant Penetrations and JointsMEHDI GHAZIspecial
04/22/2022Subsurface Investigations (Borings/Test Pits)ELIAS RASABIspecial
04/22/2022Energy Code Compliance InspectionsMEHDI GHAZIprogress
04/22/2022Fire-Resistance Rated ConstructionMEHDI GHAZIprogress
04/22/2022Structural Wood FrameMEHDI GHAZIprogress
04/22/2022Footing and FoundationMEHDI GHAZIprogress
04/22/2022Electric vehicle service equipment requirementsMEHDI GHAZIenergy_progress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/26/2026Q00723901-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q00723901-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00723901-I1Open ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026Q00723901-I1Open ↗
09/01/2026Q00723901-I1Open ↗
09/01/2026Q00723901-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026Q00723901-I1Open ↗
09/01/2026Q00723901-I1Open ↗
09/01/2026Q00723901-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q00723901-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026Q00723901-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026Q00723901-I1Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00723901-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q00723901-I1Open ↗
▸Other Documents4
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q00723901-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00723901-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/26/2026Q00723901-I1Open ↗
▸DOB NOWFinal Survey1
08/26/2026Q00723901-I1Open ↗