← Back
One story retail building
81-28 LEFFERTS BOULEVARD
QUEENS · BIN 4440788
💬 Discuss this project
1931Year Built
1Stories
K1Building Class
R4-1Zoning
—Gross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
One story retail building · Owner of record: BICU'S PLAYGROUND LLC · 0.98 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Roof1p · 1 filing · 8 docs
Floor 12p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BAISLY REALTY509/13/2026
BICU'S PLAYGROUND LLC103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEON SKVIRSKY PE107/21/2026
LAWRENCE MAREK ARCHITECT205/26/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GS CONSTRUCTION OF NY INCGeneral Contractor206/27/2026
THE SIGN LAB NYC LLCGeneral Contractor108/05/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NORMAN C. LOK818107/21/2026
CHERICO KING ARCHITECT PC5674105/26/2026
Building Lifecycle
All (28)Filed (3)Permit Issued (3)Signed Off (3)Violation (2)Inspection (1)Special Inspection (16)
08/11/2026
Signed off — Alteration
NON-ILLUMINATED NON-ADVERTISING ACCESSORY STOREFRONT AWNING - DUNKIN. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q01420331-I1
08/04/2026
Permit issued — General Construction
Q01420331-I1-GC
07/22/2026
Signed off — Alteration
Q01398745-S1
07/22/2026
Signed off — Alteration
Q01398745-I1
07/21/2026
Filed — Alteration
NON-ILLUMINATED NON-ADVERTISING ACCESSORY STOREFRONT AWNING - DUNKIN. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q01420331-I1
07/10/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/11/2026
Permit issued — Mechanical Systems
Q01398745-I1-GC-CX
06/11/2026
Permit issued — Construction Fence
Q01398745-S1-FN
05/26/2026
Filed — Alteration
Q01398745-S1
05/26/2026
Filed — Alteration
Q01398745-I1
05/08/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
LAWRENCE MAREK
05/08/2026
Special inspection requirement — Tenant Protection Plan Compliance
LAWRENCE MAREK
05/08/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
LAWRENCE MAREK
05/08/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
LAWRENCE MAREK
05/08/2026
Special inspection requirement — Energy Code Compliance Inspections
LAWRENCE MAREK
05/08/2026
Special inspection requirement — Fire-Resistance Rated Construction
LAWRENCE MAREK
05/08/2026
Special inspection requirement — Interior lighting power
LAWRENCE MAREK
05/08/2026
Special inspection requirement — Lighting controls
LAWRENCE MAREK
05/08/2026
Special inspection requirement — Maintenance information
LAWRENCE MAREK
05/08/2026
Special inspection requirement — Fenestration air leakage
LAWRENCE MAREK
05/08/2026
Special inspection requirement — Shutoff dampers
LAWRENCE MAREK
05/08/2026
Special inspection requirement — HVAC-R and service water heating equipment
LAWRENCE MAREK
05/08/2026
Special inspection requirement — Fenestration areas
LAWRENCE MAREK
05/08/2026
Special inspection requirement — HVAC-R and service water heating system controls
LAWRENCE MAREK
05/07/2026
Special inspection requirement — Mechanical Systems
LAWRENCE MAREK
05/07/2026
Special inspection requirement — Final
LAWRENCE MAREK
10/13/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/14/2021
Violation issued (ECB, closed)
Unknown
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offTHE SIGN LAB NYC LLC08/04/2026
DOB NOWMechanical SystemsSigned-offGS CONSTRUCTION OF NY INC06/11/2026
DOB NOWConstruction FenceSigned-offGS CONSTRUCTION OF NY INC06/11/2026
BISOTISSUEDFOREVIEW DEVELOPMENT INC10/06/2011
BISPLRE-ISSUEDBBM PLUMBING & HEATING INC06/25/2007
BISPLISSUEDJ & R PLBG & HTG CON INC10/30/2006
BISPLISSUEDGROWIT PLG01/11/1991
BISOTISSUEDNYKIM CONSTRUCTION CO.11/09/1990
2 jobs · most recent 06/17/2026
General Wiring
FiledStatusContractorScope
06/17/2026CompleteLIT MODE ELECL CONTG INCGeneral Wiring
11/10/2021CompleteELPO ELECTRICAL CONTG INCGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
07/10/2026Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
05/08/2026Fenestration and door U-factor and product ratingsLAWRENCE MAREKenergy_progress
05/08/2026Tenant Protection Plan ComplianceLAWRENCE MAREKspecial
05/08/2026HVAC-R and service water piping design and insulationLAWRENCE MAREKenergy_progress
05/08/2026Fire-Resistant Penetrations and JointsLAWRENCE MAREKspecial
05/08/2026Energy Code Compliance InspectionsLAWRENCE MAREKprogress
05/08/2026Fire-Resistance Rated ConstructionLAWRENCE MAREKprogress
05/08/2026Interior lighting powerLAWRENCE MAREKenergy_progress
05/08/2026Lighting controlsLAWRENCE MAREKenergy_progress
05/08/2026Maintenance informationLAWRENCE MAREKenergy_progress
05/08/2026Fenestration air leakageLAWRENCE MAREKenergy_progress
05/08/2026Shutoff dampersLAWRENCE MAREKenergy_progress
05/08/2026HVAC-R and service water heating equipmentLAWRENCE MAREKenergy_progress
05/08/2026Fenestration areasLAWRENCE MAREKenergy_progress
05/08/2026HVAC-R and service water heating system controlsLAWRENCE MAREKenergy_progress
05/07/2026Mechanical SystemsLAWRENCE MAREKspecial
05/07/2026FinalLAWRENCE MAREKprogress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/16/2026Q01398745-I1Request digital key ↗
08/16/2026Q01398745-S1Request digital key ↗
08/16/2026Q01420331-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
08/08/2011420466052Open ↗
▸BISWORK PERMIT APPLICATION1
10/07/2011420466052Open ↗
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/16/2026Q01398745-S1Open ↗
08/16/2026Q01398745-I1Open ↗
08/16/2026Q01420331-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026Q01398745-I1Open ↗
08/26/2026Q01398745-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
08/08/2011420466052Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
08/08/2011420466052Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/08/2011420466052Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q01398745-I1Open ↗
▸Safety & Tenant Protection4
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE3
10/07/2011420466052Open ↗
10/07/2011420466052Open ↗
10/07/2011420466052Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
10/07/2011420466052Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/16/2026Q01398745-I1Open ↗
▸Energy Compliance1
▸BISAS-BUILT ENERGY ANALYSIS1
02/22/2012420466052Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
02/22/2012420466052Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
08/08/2011420466052Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
02/22/2012420466052Open ↗
08/08/2011420466052Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
08/08/2011420466052Open ↗