← Back
One family attached or semi-detached
81 BLYTHE PLACE
STATEN ISLAND · BIN 5091693
💬 Discuss this project
1986Year Built
3Stories
A5Building Class
R3-2Zoning
1,872 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One family attached or semi-detached · 2,448 sf lot · 0.76 FAR built · Flood zone X
Locations of Work
Plumbing
Permit Issued — active, not yet Signed-off
Floor 1Under Construction2p · 1 filing · 5 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CQ&J CORPORATION312/18/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AMERICAN STANDARD P&H CORORP.Plumbing207/08/2026
SAFETY PRO CONSTRUCTIONGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244312/18/2025
Building Lifecycle
All (26)Filed (3)Permit Issued (3)Signed Off (1)Violation (2)Inspection (13)Special Inspection (4)
04/22/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/16/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
04/06/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/13/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/10/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/06/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/11/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/04/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
01/16/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/12/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/05/2026
Permit issued — Plumbing
S01336606-I1-PL
12/18/2025
Filed — Alteration
LEGALIZE 1 SINK AND REMOVE UNAUTHORIZED GAS PIPING AS PER PLAN TO ADDRESS OATH/ECB VIOLATION #39135306Y. FILE TO SUPERSEDE DOB JOB #S01181327-S1 TO CORRECT PLUMBING APPLICATION, AND TO MATCH ON SITE CONDITIONS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01336606-I1
12/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
12/18/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
10/20/2025
Signed off — Alteration
S01181327-I1
10/08/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
09/10/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/02/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/15/2025
Permit issued — Plumbing
S01181327-S1-PL
04/04/2025
Permit issued — General Construction
S01181327-I1-GC
02/17/2025
Filed — Alteration
S01181327-I1
02/17/2025
Filed — Alteration
S01181327-S1
02/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
02/13/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
01/13/2025
Violation issued (ECB, closed)
Construction
01/13/2025
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedAMERICAN STANDARD P&H CORORP.01/05/2026
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.04/15/2025
DOB NOWGeneral ConstructionSigned-offSAFETY PRO CONSTRUCTION04/04/2025
1 project · most recent 02/17/2025
Gas Water/Sanitary
FiledStatusContractorScope
02/17/2025Signed-offAMERICAN STANDARD P&H CORGas, Water/Sanitary
1 project · most recent 02/12/2026
General Wiring
FiledStatusContractorScope
02/12/2026CompleteJP & SON ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
04/22/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/16/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
04/06/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/13/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/10/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/06/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/11/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/04/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
01/16/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/12/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/08/2025Pass-Final General Construction Non-Directive 14PassView ↗
09/10/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/02/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
12/18/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
12/18/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
02/13/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
02/13/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/20/2026S01181327-I1Request digital key ↗
08/20/2026S01181327-S1Request digital key ↗
08/17/2026S01336606-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/20/2026S01181327-S1Open ↗
08/20/2026S01181327-I1Open ↗
08/13/2026S01336606-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026S01336606-I1Open ↗
08/24/2026S01181327-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026S01336606-I1Open ↗
08/24/2026S01181327-S1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/20/2026S01181327-S1Open ↗
08/20/2026S01181327-I1Open ↗
08/13/2026S01336606-I1Open ↗