← Back
Two stories - detached, small or mid-size
812 EAST 8 STREET
BROOKLYN · Flatbush (West)-Ditmas Park-Parkville · BIN 3170112
💬 Discuss this project
1920Year Built
2Stories
A1Building Class
R5Zoning
1,840 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,410 sf lot · 0.76 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalGeneral
Roof1 filing · 8 docs
Filed — no permit issued8p · 1 filing · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/09/2019$859K—— → —$467/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ETRECTE LLC204/03/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PATRIOT ENERGY SOLUTIONS CORP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PATRIOT ENERGY SOL COGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ETRECTE LLC8116204/03/2024
Building Lifecycle
All (34)Filed (2)Permit Issued (1)Objection (21)Special Inspection (10)
04/05/2024
Permit issued — Solar
B01028400-I1-SL
04/03/2024
Filed — Alteration
ROOFTOP SOLAR PANEL INSTALATION
B01028400-I1
04/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
VYACHESLAV NECHAYEV
04/01/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
VYACHESLAV NECHAYEV
04/01/2024
Special inspection requirement — Energy Code Compliance Inspections
VYACHESLAV NECHAYEV
04/01/2024
Special inspection requirement — Final
VYACHESLAV NECHAYEV
04/01/2024
Special inspection requirement — Air barrier - visual inspection
VYACHESLAV NECHAYEV
03/12/2024
Objection resolved — Resolved
03/12/2024
Objection resolved — Resolved
03/12/2024
Objection resolved — Resolved
03/12/2024
Objection resolved — Resolved
03/12/2024
Objection resolved — Resolved
02/29/2024
Objection raised — Other
02/29/2024
Objection raised — Other
02/29/2024
Objection raised — Other
02/29/2024
Objection raised — Other
02/23/2024
Objection resolved — Addressed
02/23/2024
Objection resolved — Resolved
02/23/2024
Objection resolved — Addressed
02/23/2024
Objection resolved — Resolved
02/23/2024
Objection resolved — Resolved
02/15/2024
Objection raised — Other
02/15/2024
Objection raised — Other
02/15/2024
Objection raised — Other
02/15/2024
Objection raised — Other
02/15/2024
Objection raised — Other
02/15/2024
Objection raised — Other
02/15/2024
Objection raised — Other
02/07/2024
Filed — Alteration
ROOFTOP SOLAR PANEL INSTALLATION
B00989562-I1
01/12/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
VYACHESLAV NECHAYEV
01/12/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
VYACHESLAV NECHAYEV
01/12/2024
Special inspection requirement — Energy Code Compliance Inspections
VYACHESLAV NECHAYEV
01/12/2024
Special inspection requirement — Final
VYACHESLAV NECHAYEV
01/12/2024
Special inspection requirement — Air barrier - visual inspection
VYACHESLAV NECHAYEV
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedPATRIOT ENERGY SOL CO04/05/2024
1 project · most recent 01/04/2024
FiledStatusContractorScope
01/04/2024Permit IssuedMAK ELECTRICAL CONTR CORP1 meters
2 projects · most recent 04/03/2024
FiledStatusContractorScope
04/03/2024Permit IssuedPATRIOT ENERGY SOL CO21 panels, 8.4 kw, 990 roof_area_sqft
02/07/2024———
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
04/01/2024Fire-Resistant Penetrations and JointsVYACHESLAV NECHAYEVspecial
04/01/2024Structural Stability – Alterations of existing buildingsVYACHESLAV NECHAYEVspecial
04/01/2024Energy Code Compliance InspectionsVYACHESLAV NECHAYEVprogress
04/01/2024FinalVYACHESLAV NECHAYEVprogress
04/01/2024Air barrier - visual inspectionVYACHESLAV NECHAYEVenergy_progress
01/12/2024Fire-Resistant Penetrations and JointsVYACHESLAV NECHAYEVspecial
01/12/2024Structural Stability – Alterations of existing buildingsVYACHESLAV NECHAYEVspecial
01/12/2024Energy Code Compliance InspectionsVYACHESLAV NECHAYEVprogress
01/12/2024FinalVYACHESLAV NECHAYEVprogress
01/12/2024Air barrier - visual inspectionVYACHESLAV NECHAYEVenergy_progress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/26/2026B00989562-I1Request digital key ↗
08/25/2026B01028400-I1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
09/29/2026B00989562-I1Open ↗
09/29/2026B00989562-I1Open ↗
09/29/2026B00989562-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/29/2026B00989562-I1Open ↗
09/29/2026B00989562-I1Open ↗
08/26/2026B01028400-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B01028400-I1Open ↗
08/13/2026B00989562-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026B01028400-I1Open ↗
08/13/2026B00989562-I1Open ↗