← Back
Elevator cooperative
812 PARK AVENUE
MANHATTAN · BIN 1041660
💬 Discuss this project
1958Year Built
14Stories
D4Building Class
R10Zoning
154,827 sfGross Floor Area
45Units
LL97 CoveredRent Stabilized7 Open Violations ▸FISP: SAFE
Elevator cooperative · Owner of record: 812 CORPORATION · 14,050 sf lot · 11.02 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
Roof2p · 1 filing · 9 docs
PenthouseUnder Construction17p · 2 filings · 20 docs
Floor 155p · 1 filing · 9 docs
Floor 14Under Construction6p · 2 filings · 20 docs
Floor 13Under Construction6p · 2 filings · 20 docs
Floor 127p · 1 filing · 4 docs
Floor 11
Floor 108p · 3 filings · 20 docs
Floor 9
Floor 81p · 1 filing · 5 docs
Floor 7
Floor 64p · 2 filings · 20 docs
Floor 51p · 1 filing · 17 docs
Floor 45p · 1 filing · 14 docs
Floor 3
Floor 2
Floor 1Under Construction11p · 3 filings · 20 docs
Cellar4p · 1 filing · 10 docs
4 jobs · most recent 07/03/2025
Air Conditioning Systems Heating and Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
07/03/2025Permit IssuedRUSK RENOVATIONS, INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric PVFY-P18NAMU-E1 18,000 BTU · Vrf Indoor ×4
PVFY-P24NAMU-E1 24,000 BTU · Vrf Indoor ×3
MXZ-S36NAM2-U1 36,000 BTU · Heat Pump Outdoor ×2
MXZ-SM48NAM2-U1 48,000 BTU · Heat Pump Outdoor ×1
MXZ-SM60NAM2-U1 60,000 BTU · Heat Pump Outdoor ×1
PVFY-P36NAMU-E1 36,000 BTU · Vrf Indoor ×1
03/24/2025Signed-offANDALORO CONSTRUCTION LLCAir Conditioning Systems
Cooling
Ice Air N/A 16,900 BTU · Ptac ×12
Carrier Carrier - FJ5ANYC30L00 27,200 BTU · Ahu ×8
National Comfort National Comfort Products - NCP5304000A-A2 Deluxe 27,200 BTU · Condensing Unit ×8
10/15/2021Permit IssuedKLDNY INCAir Conditioning Systems
Cooling
Mitsubishi Electric PEFY-P30NMAU-E2 30,000 BTU · Vrf Indoor ×2
PUMY-P60NKMU 60,000 BTU · Vrf Outdoor ×1
04/22/2021Permit IssuedRUSK APARTMENT, LLCAir Conditioning Systems, Heating Systems
Cooling
National Comfort NCPE-430-4010 27,200 BTU · Condensing Unit ×3
3 jobs · most recent 03/24/2025
Water/Sanitary Gas
FiledStatusContractorScope
03/24/2025Signed-offGOLDS PLUMBING CORPWater/Sanitary
10/24/2024——Water/Sanitary
01/28/2022Signed-offDONATO PLUMBING, INCGas, Water/Sanitary
24 jobs · most recent 07/28/2026
General Wiring Lighting HVAC Wiring
FiledStatusContractorScope
07/28/2026Permit IssuedJAS ELEC'L SERVICES, INCGeneral Wiring
05/26/2026Permit IssuedHIGH QUALITY ELEC.OF NYC—
04/28/2026CompleteLENS ELECTRIC, INC—
01/06/2026Permit IssuedR.C.M. ELECTRIC CORP.—
07/03/2025CompleteWMS ELECTRICAL CONTNG LTDGeneral Wiring
05/29/2025CompletePOLYPHASE ELECTRIC INC.General Wiring
03/06/2025CompleteEIS ELECTRIC CORP DBAGeneral Wiring
02/24/2025CompleteIRWIN ELECTR'L CONTR'S, IGeneral Wiring
07/16/2024CompleteECO ELECTRICAL SERVCS LLCGeneral Wiring, Lighting
05/02/2024CompleteECO ELECTRICAL SERVCS LLC—
03/27/2024CompleteEINSTEIN ELEC'L CORPGeneral Wiring
03/23/2023CompleteEINSTEIN ELEC'L CORP—
03/02/2023CompleteCONTACT ELECTRIC CORPGeneral Wiring
12/06/2022CompleteACCURATE ELEC'L CORP.General Wiring
08/25/2022Permit IssuedH. & L. ELECTRIC INC11 meters, 1 new_meters
1 job · most recent 06/11/2026
Scaffold Sidewalk Shed
FiledStatusContractorScope
06/11/2026Permit IssuedKINGS GROUP NY CORPScaffold, Sidewalk Shed
2 jobs · most recent 07/03/2025
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
07/03/2025Permit IssuedRUSK RENOVATIONS, INCTenant Protection Plan 72 Hour
07/03/2025Permit IssuedRUSK RENOVATIONS, INCTenant Protection Plan 72 Hour
Building Lifecycle
All (276)Filed (49)Permit Issued (44)Signed Off (20)Facade (FISP) (12)Violation (60)Inspection (25)Objection (36)Special Inspection (30)
09/28/2026
Permit issued — Suspended Scaffold
M01413214-I1-SC
08/11/2026
Filed — Alteration
REMOVAL AND INSTALLATION OF INTERIOR PARTIONS FOR ACCESSORY AMENITY SPACE ON THE 1ST FLOOR AND MINOR PARTITION WORK IN THE CELLAR. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01213361-S1
07/22/2026
Signed off — Alteration
Replacement of existing air conditioning units to provide cooling for existing duplex dwelling unit. Related ductwork and diffusers. Install electric radiant heat in toilet. No change to use, egress or occupancy under this application.
M01196904-I1
07/21/2026
Signed off — Alteration
Replacement of existing air conditioning units to provide cooling for existing duplex dwelling unit. Related ductwork and diffusers. Install electric radiant heat in toilet. No change to use, egress or occupancy under this application.
M01196904-S1
07/14/2026
Permit issued — General Construction
M01213361-I1-GC
06/23/2026
Filed — Alteration
Filing to patch, repair, replace facade surface areas as indicated on the plans. Also filing railing modification at West Penthouse terrace. No change in use, egress, or occupancy under this application.
M01379617-I1
06/16/2026
Signed off — Alteration
Replacement of existing air conditioning units to provide cooling for existing duplex dwelling unit. Related ductwork and diffusers. Install electric radiant heat in toilet. No change to use, egress or occupancy under this application.
M01196904-S2
06/12/2026
Permit issued — Supported Scaffold
M01410754-S1-SF
06/12/2026
Permit issued — Sidewalk Shed
M01410754-I1-SH
06/11/2026
Filed — Alteration
installation of heavy duty sidewalk shed. no change in use, occupancy or egress. all work to comply with chapter 33 of nycbc
M01410754-S1
06/11/2026
Filed — Alteration
installation of heavy duty sidewalk shed. no change in use, occupancy or egress. all work to comply with chapter 33 of nycbc
M01410754-I1
06/11/2026
Special inspection requirement — Post-installed Anchors
Navkiran Cheema
04/13/2026
Permit issued — General Construction
M01196904-I1-GC
04/13/2026
Permit issued — Mechanical Systems
M01196904-S2-MS
03/27/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Chester Kowalski
03/27/2026
Special inspection requirement — Tenant Protection Plan Compliance
03/27/2026
Special inspection requirement — Final
RICHARD LEFEVER
11/24/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/03/2025
Signed off — Alteration
Renovation of an existing apartment 9/10 D work to be done on the 10th Floor only . No change to use, egress or occupancy.
M00717682-S2
10/02/2025
Permit issued — Mechanical Systems
M01211168-I1-MS
10/02/2025
Permit issued — General Construction
M01211156-I1-GC
10/01/2025
Signed off — Alteration
Renovation of an existing apartment 9/10 D work to be done on the 10th Floor only . No change to use, egress or occupancy.
M00717682-I1
09/11/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/07/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/07/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/18/2025
Objection resolved — Addressed
07/17/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/16/2025
Permit issued — General Construction
M01211156-I1-GC
07/16/2025
Permit issued — Mechanical Systems
M01211168-I1-MS
07/16/2025
Objection raised — Admin
07/15/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/03/2025
Filed — Alteration
REMOVAL AND INSTALLATION OF INTERIOR PARTITIONS, CEILINGS, AND FLOORING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01211156-I1
07/03/2025
Filed — Alteration
MODIFICATION OF DUCTORK AND REPLACEMENTS OF AC UNITS.
M01211168-I1
07/01/2025
Filed — Alteration
REMOVAL AND INSTALLATION OF INTERIOR PARTIONS FOR ACCESSORY AMENITY SPACE ON THE 1ST FLOOR AND MINOR PARTITION WORK IN THE CELLAR. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01213361-I1
05/20/2025
Signed off — Alteration
GENERAL CONSTRUCTION FOR INTERIOR RENOVATIONS OF APARTMENT 9/10B & EXTERIOR OPENINGS FOR ASSOCIATED MECHANICAL EQUIPMENT FILED SEPARATELY AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01016271-I1
05/20/2025
Signed off — Alteration
M01018498-I1
05/13/2025
Signed off — Alteration
Installation of Sidewalk Shed as per plans.
M00066797-I1
05/09/2025
Permit issued — Mechanical Systems
M01018498-I1-MS
05/01/2025
Permit issued — General Construction
M01196904-I1-GC
04/29/2025
Permit issued — Plumbing
M01196904-S1-PL
04/28/2025
Permit issued — Mechanical Systems
M01196904-S2-MS
04/22/2025
Special inspection requirement — Fire-Resistance Rated Construction
Stephen Killcoyne
04/22/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Daniel Allen
04/22/2025
Special inspection requirement — Post-installed Anchors
MAURICIO ANDRADE
04/21/2025
Special inspection requirement — Final
Stephen Killcoyne
04/21/2025
Special inspection requirement — Tenant Protection Plan Compliance
Daniel Allen
04/15/2025
Special inspection requirement — Mechanical Systems
ERIC BERLENT
04/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ERIC BERLENT
04/15/2025
Special inspection requirement — Final
ANDREW BALLARD, AIA
04/04/2025
Special inspection requirement — Post-installed Anchors
Brian Bercarich
04/04/2025
Special inspection requirement — Final
Brian Bercarich
04/04/2025
Special inspection requirement — Masonry
Gregory Moormann
04/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Brian Bercarich
04/04/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Gregory Moormann
04/04/2025
Special inspection requirement — Tenant Protection Plan Compliance
Ari Kamo
04/04/2025
Special inspection requirement — Energy Code Compliance Inspections
Brian Bercarich
04/04/2025
Special inspection requirement — Fire-Resistance Rated Construction
Brian Bercarich
03/28/2025
Signed off — Alteration
PLUMBING WORK FOR INTERIOR RENOVATIONS OF APARTMENT 9/10B AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01018532-I1
03/27/2025
Filed — Alteration
GENERAL CONSTRUCTION FOR INTERIOR RENOVATIONS OF APARTMENT 9/10B & EXTERIOR OPENINGS FOR ASSOCIATED MECHANICAL EQUIPMENT FILED SEPARATELY AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01016271-P2
03/24/2025
Filed — Alteration
Replacement of existing air conditioning units to provide cooling for existing duplex dwelling unit. Related ductwork and diffusers. Install electric radiant heat in toilet. No change to use, egress or occupancy under this application.
M01196904-S1
Latest 60 of 276 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KINGS GROUP NY308/29/2026
STEEL SYSTEMS807/08/2026
FIOCCHI GROUP1807/08/2026
LC THREE707/08/2026
812 CORPORATION1303/22/2026
812 PARK AVE CORP C O703/22/2026
DOUGLAS ELLIMAN PROPERTY103/22/2026
OWNER OF 45 EAST 75 STREE103/22/2026
DOUGLAS ELLIMAN103/21/2026
PRUZAN103/21/2026
▾Filing Representatives (Expediters)
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KLDNY INCGeneral Contractor707/08/2026
STEEL SYSTEMS LLCGeneral Contractor707/08/2026
FIOCCHI GROUP LLCGeneral Contractor707/08/2026
ANDALORO CONSTRUCTION LLCGeneral Contractor507/08/2026
S. DONADIC INCGeneral Contractor507/08/2026
ARISTA AIR CONDITIONING CORPGeneral Contractor403/21/2026
RUSK APARTMENT, LLCGeneral Contractor407/08/2026
JGR GROUP INCGeneral Contractor403/21/2026
DONATO PLUMBING, INCPlumbing307/08/2026
RUSK RENOVATIONS, INCGeneral Contractor307/08/2026
ARTISTIC CONTRACTINGGeneral Contractor303/21/2026
NEXUS CONSULTING GROUPGeneral Contractor303/21/2026
ALBERT STIEFELElectrical203/21/2026
HIGHLINE CONSTRUCTION GRGeneral Contractor207/08/2026
KINGS GROUP NY CORPGeneral Contractor207/08/2026
MCCORMACK CONTRACTING INC.General Contractor203/21/2026
THOMPSON MICHAELElectrical103/21/2026
STEVEN PALMOElectrical103/21/2026
HUDSON PLMBING & MCH, LLCPlumbing106/28/2026
ROBERT MARCHISOTTOElectrical103/21/2026
J&M PLUMBING OF WESTCHESTERPlumbing107/08/2026
RICHARD GRIMAElectrical103/21/2026
PREMIER FLOW PLBG AND HTGPlumbing107/08/2026
R.C.M. ELECTRIC CORP.Electrical103/22/2026
POLYPHASE ELECTRIC INC.Electrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SAG ENGINEERING & CONSULT608106/23/2026
CATALPA SPECIAL INSPECTIO2004107/03/2025
ALLEN+KILLCOYNE ARCHITECT2697207/01/2025
PSI AGENCY INC.254107/01/2025
AK ENGINEERING PC678403/27/2025
B2 ENGINEERING D.P.C.5433603/27/2025
ANTHONY MORALI ARCHITECT4810303/24/2025
WAVIC ENGINEERING PLLC1733103/21/2025
MEP INSPECTIONS, INC1102310/24/2024
JAREK TRESKO ARCHITECT, L1086107/08/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSuspended ScaffoldPermit IssuedMASPETH CONTRACTING CORP09/28/2026
DOB NOWGeneral ConstructionPermit IssuedAIK RENOVATION INC07/14/2026
DOB NOWSupported ScaffoldPermit IssuedKINGS GROUP NY CORP06/12/2026
DOB NOWSidewalk ShedPermit IssuedKINGS GROUP NY CORP06/12/2026
DOB NOWGeneral ConstructionSigned-offANDALORO CONSTRUCTION LLC04/13/2026
DOB NOWMechanical SystemsSigned-offANDALORO CONSTRUCTION LLC04/13/2026
DOB NOWMechanical SystemsPermit IssuedRUSK RENOVATIONS, INC10/02/2025
DOB NOWGeneral ConstructionPermit IssuedRUSK RENOVATIONS, INC10/02/2025
DOB NOWGeneral ConstructionPermit IssuedVMMA CONSTRUCTION LLC07/16/2025
DOB NOWMechanical SystemsPermit IssuedRUSK RENOVATIONS, INC07/16/2025
DOB NOWMechanical SystemsSigned-offFIOCCHI GROUP LLC05/09/2025
DOB NOWGeneral ConstructionSigned-offANDALORO CONSTRUCTION05/01/2025
DOB NOWPlumbingSigned-offHUDSON PLMBING & MCH, LLC04/29/2025
DOB NOWMechanical SystemsSigned-offANDALORO CONSTRUCTION04/28/2025
DOB NOWGeneral ConstructionSigned-offJGR GROUP11/20/2024
DOB NOWGeneral ConstructionSigned-offFIOCCHI GROUP LLC10/18/2024
DOB NOWGeneral ConstructionSigned-offJGR GROUP07/23/2024
DOB NOWPlumbingSigned-offDONATO PLUMBING, INC04/17/2024
DOB NOWGeneral ConstructionSigned-offFIOCCHI GROUP LLC04/11/2024
DOB NOWGeneral ConstructionSigned-offSAPOL CONSTRUCTION LLC08/01/2023
DOB NOWMechanical SystemsSigned-offSAPOL CONSTRUCTION LLC08/01/2023
DOB NOWMechanical SystemsSigned-offSAPOL CONSTRUCTION LLC05/23/2023
DOB NOWPlumbingSigned-offDONATO PLUMBING, INC05/23/2023
DOB NOWGeneral ConstructionSigned-offSAPOL CONSTRUCTION LLC05/23/2023
DOB NOWGeneral ConstructionSigned-offHIGHLINE CONSTRUCTION GR04/25/2023
DOB NOWMechanical SystemsSigned-offHIGHLINE CONSTRUCTION GR04/25/2023
DOB NOWMechanical SystemsSigned-offNEXUS CONSULTING GROUP06/03/2022
DOB NOWPlumbingSigned-offBMV MECHANICAL CORP05/31/2022
DOB NOWGeneral ConstructionSigned-offARTISTIC CONTRACTING05/09/2022
DOB NOWMechanical SystemsPermit IssuedKLDNY10/20/2021
DOB NOWGeneral ConstructionPermit IssuedKLDNY09/21/2021
DOB NOWGeneral ConstructionPermit IssuedKLDNY09/15/2021
DOB NOWMechanical SystemsPermit IssuedRUSK APARTMENT, LLC06/07/2021
DOB NOWGeneral ConstructionSigned-offRUSK APARTMENT, LLC06/07/2021
DOB NOWPlumbingSigned-offDONATO PLUMBING, INC06/07/2021
DOB NOWPlumbingSigned-offGALICJA PLBG AND HTG.CORP05/17/2021
DOB NOWGeneral ConstructionPermit IssuedKLDNY05/14/2021
DOB NOWPlumbingSigned-offJ&M PLUMBING OF WESTCHEST04/29/2021
DOB NOWGeneral ConstructionSigned-offMCCORMACK CONTRACTING INC04/22/2021
DOB NOWMechanical SystemsSigned-offARISTA AIR CONDITIONING C11/19/2019
+ 54 more permits on file
▾Field Inspections (DOB CAP) — 25
DateTypeResultReport
11/24/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/11/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/07/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/07/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/17/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/15/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/26/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/29/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/25/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/03/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/28/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/11/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/11/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/28/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/07/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/07/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/10/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/09/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/23/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
01/28/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/10/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/27/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/06/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/23/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/21/2021Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 85
DateRequirementInspectorRole
06/11/2026Post-installed AnchorsNavkiran Cheemaspecial
03/27/2026FinalRICHARD LEFEVERprogress
03/27/2026Tenant Protection Plan Compliance—special
03/27/2026Structural Stability – Alterations of existing buildingsChester Kowalskispecial
04/22/2025Post-installed AnchorsMAURICIO ANDRADEspecial
04/22/2025Fire-Resistance Rated ConstructionStephen Killcoyneprogress
04/22/2025Fire-Resistant Penetrations and JointsDaniel Allenspecial
04/21/2025Tenant Protection Plan ComplianceDaniel Allenspecial
04/21/2025FinalStephen Killcoyneprogress
04/15/2025FinalANDREW BALLARD, AIAprogress
04/15/2025Mechanical SystemsERIC BERLENTspecial
04/15/2025Fire-Resistant Penetrations and JointsERIC BERLENTspecial
04/04/2025Fire-Resistant Penetrations and JointsBrian Bercarichspecial
04/04/2025Tenant Protection Plan ComplianceAri Kamospecial
04/04/2025Fire-Resistance Rated ConstructionBrian Bercarichprogress
04/04/2025FinalBrian Bercarichprogress
04/04/2025Post-installed AnchorsBrian Bercarichspecial
04/04/2025Structural Stability – Alterations of existing buildingsGregory Moormannspecial
04/04/2025Energy Code Compliance InspectionsBrian Bercarichprogress
04/04/2025MasonryGregory Moormannspecial
03/18/2025Mechanical SystemsANTHONY MORALIspecial
03/18/2025FinalIlya Malyuchenkoprogress
11/07/2024Fire-Resistant Penetrations and JointsNicolas Crosettospecial
11/07/2024Post-installed AnchorsNicolas Crosettospecial
11/07/2024FinalCHARLOTTE WORTHYprogress
Latest 25 of 85.
▾Documents — 963 on file (BIS + DOB NOW)
▸Plans & Drawings52
▸DOB NOWPlans/Sketch49
09/06/2026M00066797-I1Request digital key ↗
09/03/2026M00494759-I1Request digital key ↗
09/03/2026M00494759-P1Request digital key ↗
Showing 3 of 49 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/05/2026M00227361-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
09/03/2026M00473774-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction1
09/03/2026M00476752-I1Request digital key ↗
▸Applications & Permits210
▸BISWORK PERMIT APPLICATION93
07/24/2019123574293Open ↗
03/04/2019123499115Open ↗
03/04/2019123499115Open ↗
Showing 3 of 93 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION67
07/16/2024103577103Open ↗
07/10/2024103518301Open ↗
07/10/2024103577103Open ↗
Showing 3 of 67 on file for this type
▸DOB NOWLPC Approval/Permit49
09/03/2026M00494759-P1Open ↗
09/03/2026M00494759-I1Open ↗
09/03/2026M00495823-P2Open ↗
Showing 3 of 49 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
08/20/2024103577103Open ↗
▸Seals & Professional Certifications248
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION106
12/19/2019123521652Open ↗
12/19/2019123521652Open ↗
12/19/2019123521652Open ↗
Showing 3 of 106 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature52
09/03/2026M00473774-I1Open ↗
09/03/2026M00494759-P1Open ↗
09/03/2026M00494759-I1Open ↗
Showing 3 of 52 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature41
09/23/2026M01211168-I1Open ↗
09/23/2026M01211168-I1Open ↗
09/19/2026M00495823-P1Open ↗
Showing 3 of 41 on file for this type
▸DOB NOWProgress Inspector Seal & Signature36
09/23/2026M01211168-I1Open ↗
09/01/2026M00717682-I1Open ↗
08/31/2026M00496547-I1Open ↗
Showing 3 of 36 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
06/19/2018123574293Open ↗
Showing 1 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
06/19/2018123574293Open ↗
Showing 1 of 2 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISPC FULL REPORT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Trade Schedules & Equipment72
▸BISSELF-CERT PLUMBING NOTICE35
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 35 on file for this type
▸BISSCHEDULE B - PLUMBING22
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 22 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE10
01/02/2019123499115Open ↗
07/17/2018123499115Open ↗
07/10/2018123521652Open ↗
Showing 3 of 10 on file for this type
▸BISEQUIPMENT USE PERMITS3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Safety & Tenant Protection15
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE6
06/04/2018123499115Open ↗
06/04/2018123499115Open ↗
06/04/2018123499115Open ↗
Showing 3 of 6 on file for this type
▸BISTenant Protection Plan and Notes5
07/10/2018123521652Open ↗
06/19/2018123574293Open ↗
04/25/2018123499115Open ↗
Showing 3 of 5 on file for this type
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM2
04/25/2018123499115Open ↗
05/25/2016122750521Open ↗
▸BIS* SHORING 27-10101
08/20/2024103577103Open ↗
▸DOB NOWTenant Protection Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos63
▸DOB NOWDEP ACP-5: Asbestos Assessment Report32
09/03/2026M00473774-I1Open ↗
09/02/2026M00634943-P1Open ↗
09/02/2026M00634943-I1Open ↗
Showing 3 of 32 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'13
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 13 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)9
07/10/2018123521652Open ↗
04/25/2018123499115Open ↗
05/30/2017123029123Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form6
09/03/2026M00496627-I1Open ↗
09/03/2026M00496646-I1Open ↗
08/31/2026M00827058-S1Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
08/15/2018123574293Open ↗
▸Energy Compliance39
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS14
06/19/2018123574293Open ↗
05/23/2016140340539Open ↗
05/23/2016140340539Open ↗
Showing 3 of 14 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS9
07/14/2020123574293Open ↗
07/13/2020123574293Open ↗
Showing 2 of 9 on file for this type
▸BISTR8: Energy Code Progress Inspections7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISENERGY CODE 1ST REVIEW COMPLETE3
05/08/2018123499115Open ↗
04/25/2018123499115Open ↗
04/07/2016122750521Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
07/14/2020123574293Open ↗
07/13/2020123574293Open ↗
▸BISTECHNICAL REPORT: ENERGY2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWEN2: As Built Energy Analysis.2
09/03/2026M00494759-I1Open ↗
Showing 1 of 2 on file for this type
▸Inspections & Test Reports11
▸BISTECHNICAL REPORT: RESPONSIBILITY7
08/20/2024103577103Open ↗
08/20/2024103577103Open ↗
08/07/2024103518301Open ↗
Showing 3 of 7 on file for this type
▸BIS* STRUCTURAL STABILITY 1 RCNY:16-011
08/20/2024103577103Open ↗
▸BIS* WELDING 27-6161
08/20/2024103577103Open ↗
▸BIS* FINAL INSPECTION DIRECTIVE 14 OF 19751
08/07/2024103518301Open ↗
▸BISFINAL INSPECTION REQUIRED1
08/21/2024103577103Open ↗
▸Approvals, Objections & Sign-offs89
▸BISLANDMARKS APPROVAL34
12/19/2019123521652Open ↗
07/10/2018123521652Open ↗
06/19/2018123574293Open ↗
Showing 3 of 34 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST27
08/21/2024103577103Open ↗
08/08/2024103518301Open ↗
07/14/2020123574293Open ↗
Showing 3 of 27 on file for this type
▸BISADMINISTRATIVE OBJECTIONS14
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 14 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION6
05/01/2017123029123Open ↗
Showing 1 of 6 on file for this type
▸DOB NOWDEP Variance (V5) letter5
09/02/2026M00709437-I1Open ↗
Showing 1 of 5 on file for this type
▸BISLANDMARKS SIGNOFF3
08/21/2024103577103Open ↗
08/08/2024103518301Open ↗
07/13/2020123574293Open ↗
▸Cost, Insurance & Ownership70
▸BISCOST AFFIDAVIT69
08/07/2024103518301Open ↗
07/14/2020123574293Open ↗
07/13/2020123574293Open ↗
Showing 3 of 69 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT1
05/25/2016122750521Open ↗
▸Filing & Intake Forms68
▸BISADDITIONAL INFORMATION30
07/08/2020123574293Open ↗
07/31/2018123499115Open ↗
07/26/2018123499115Open ↗
Showing 3 of 30 on file for this type
▸BISEFILING COVER SHEET26
07/10/2018123521652Open ↗
06/19/2018123574293Open ↗
04/25/2018123499115Open ↗
Showing 3 of 26 on file for this type
▸BISBOROUGH INTAKE FORM9
06/12/2020123574293Open ↗
04/27/2020123574293Open ↗
12/19/2019123521652Open ↗
Showing 3 of 9 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸Other Documents26
▸DOB NOWProof of Historic Building15
08/31/2026M00709423-P1Open ↗
08/31/2026M00709423-I1Open ↗
Showing 2 of 15 on file for this type
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION6
03/21/2017123029123Open ↗
05/25/2016122750521Open ↗
Showing 2 of 6 on file for this type
▸BISUnknown2
08/28/2019123499115Open ↗
08/28/2019123499115Open ↗
▸BISSupporting Document: Fee Exempt1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BIS* HIGH STRENGTH BOLTS TABLE 10-21
08/20/2024103577103Open ↗
▸BISDepartment of Consumer Affairs (DCA) Form1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type