← Back
Elevator apt, fireproof with stores
814 40 STREET
BROOKLYN · BIN 3395956
💬 Discuss this project
2004Year Built
6Stories
D6Building Class
R6Zoning
10,516 sfGross Floor Area
12Units
Rent Stabilized1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Elevator apt, fireproof with stores · Owner of record: 840 REALTY GROUP LLC · 2,504 sf lot · 4.2 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalPlumbingGeneral
Roof8p · 4 filings · 19 docs
Floor 11p · 1 filing · 5 docs
Cellar4p · 3 filings · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GREEN FOUNTAIN LLC703/22/2026
AT&T MOBILITY303/22/2026
840 REALTY GROUP903/22/2026
ALLIANCE BLDG SERVICES203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASHER ARCHITECT110/28/2024
AZIMUTH ENGINEERING211/22/2022
DEWBERRY ENGINEERS INC108/28/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CONSTRUCTION PERMIT SERVICES103/21/2026
NYC PERMIT SERVICES203/21/2026
CCM CONSULTING GROUP, INC.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
OVERLAND CONTRACTING INCGeneral Contractor407/08/2026
CROSSLINK WIRELESS LLCGeneral Contractor203/21/2026
FEASER, KENNETHElectrical103/21/2026
UCHETEL, ROBERTElectrical103/21/2026
WAGNER, PETERElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JEREMY K MCKEON, P.E.7263211/22/2022
R MARSAC CONSULTING LLC329108/28/2020
Building Lifecycle
All (49)Filed (4)Permit Issued (3)Signed Off (1)Violation (16)Objection (16)Special Inspection (9)
10/28/2024
Filed — Alteration CO
Interior renovation for community facility in cellar and first floor.
B01123120-I1
01/20/2023
Permit issued — General Construction
B07997362-I1-GC-CX
12/09/2022
Objection raised — Scope
12/09/2022
Objection resolved — Addressed
12/09/2022
Objection raised — Scope
12/09/2022
Objection resolved — Addressed
12/09/2022
Objection raised — Scope
12/09/2022
Objection resolved — Addressed
12/09/2022
Objection raised — Admin
12/09/2022
Objection resolved — Addressed
12/09/2022
Objection raised — Inspections
12/09/2022
Objection resolved — Addressed
12/09/2022
Objection raised — Scope
12/09/2022
Objection resolved — Addressed
12/09/2022
Objection raised — Admin
12/09/2022
Objection resolved — Addressed
12/09/2022
Objection raised — Fire_Protection
12/09/2022
Objection resolved — Addressed
11/22/2022
Filed — Alteration
Installation of non-emergency gas fired generator and related gas booster pump on new steel platform on roof. Relocation of existing condensing units, approved under application 320963999, to new steel platform. No change to occupancy, use, or egress.
B07997362-I1
11/22/2022
Filed — Alteration
Installation of gas meter and gas piping as per plans. No change to occupancy, use, or egress.
B07997382-I1
11/21/2022
Special inspection requirement — Tenant Protection Plan Compliance
Jeremy McKeon
11/21/2022
Special inspection requirement — Tenant Protection Plan Compliance
Jeremy McKeon
10/06/2022
Special inspection requirement — Structural Steel - High Strength Bolting
Jeremy McKeon
10/06/2022
Special inspection requirement — Structural Steel - Welding
Jeremy McKeon
10/06/2022
Special inspection requirement — Post-installed Anchors
Jeremy McKeon
10/06/2022
Special inspection requirement — Post-installed Anchors
Jeremy McKeon
09/01/2022
Special inspection requirement — Final
Jeremy McKeon
09/01/2022
Special inspection requirement — Mechanical Systems
Jeremy McKeon
09/01/2022
Special inspection requirement — Structural Steel - Details
Jeremy McKeon
05/13/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/06/2021
Signed off — Alteration
B00364306-I1
09/03/2020
Permit issued — Antenna
B00364306-I1-AN
08/28/2020
Filed — Alteration
B00364306-I1
06/30/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/18/2020
Permit issued — Antenna
B00258076-I1-AN
05/03/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/08/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/16/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/18/2013
Violation issued (HPD, closed)
B
04/18/2013
Violation issued (HPD, closed)
B
04/18/2013
Violation issued (HPD, closed)
B
04/18/2013
Violation issued (HPD, closed)
A
06/10/2011
Violation issued (ECB, closed)
Construction
03/04/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/21/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/30/2004
Violation issued (ECB, closed)
Construction
11/24/2004
Violation issued (ECB, closed)
Construction
11/19/2004
Violation issued (ECB, closed)
Unknown
10/07/2004
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedOVERLAND CONTRACTING INC01/20/2023
DOB NOWAntennaSigned-offOVERLAND CONTRACTING INC09/03/2020
DOB NOWAntennaPermit IssuedSTEADFAST DEVEL AND CONS06/18/2020
BISOTISSUEDDIGITAL CONST TECH, LLC01/03/2017
BISOTISSUEDRAMAPO COMMUNICATION CORP02/20/2015
BISOTISSUEDATCO RESTORATION INC05/30/2014
BIS—ISSUEDALLIANCE BUILDING SERV. C08/12/2008
BISEQISSUEDALLIANCE BUILDING SERV. CS08/12/2008
BISPLISSUEDW.G. PL & HTG08/05/2008
BIS—ISSUEDALLIANCE BUILDING SERV. C12/27/2007
BISSPISSUEDRIGHTWAY PLBG AND HTG INC12/06/2007
BISMHISSUEDALLIANCE BUILDING SERVICES CORP.11/30/2007
BISPLISSUEDW.G.PLBG & HTNG10/26/2007
BISEQISSUEDALLIANCE BUILDING SERV. CS12/26/2006
BISEQISSUEDROCKLEDGE SCAFFOLD CORP03/31/2006
BISPLISSUEDW.G. PL & HTG03/09/2006
BISEQISSUEDALLIANCE BUILDING SERVICES12/27/2005
BIS—ISSUEDALLIANCE BLDG SERVICES12/27/2005
BISEQISSUEDROCKLEDGE SCAFFOLD CORP09/07/2005
BIS—ISSUEDALLIANCE BLDG SERVICES01/07/2005
BISEQISSUEDALLIANCE BUILDING SERVICES01/07/2005
BIS—ISSUEDALLIANCE BLDG SERVICES03/17/2004
BISEQISSUEDALLIANCE BUILDING SERVICES03/17/2004
BISEQISSUEDALLIANCE BUILDING SERVICES03/17/2004
1 project · most recent 11/22/2022
Gas
FiledStatusContractorScope
11/22/2022——Gas
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
11/21/2022Tenant Protection Plan ComplianceJeremy McKeonspecial
11/21/2022Tenant Protection Plan ComplianceJeremy McKeonspecial
10/06/2022Structural Steel - High Strength BoltingJeremy McKeonspecial
10/06/2022Structural Steel - WeldingJeremy McKeonspecial
10/06/2022Post-installed AnchorsJeremy McKeonspecial
10/06/2022Post-installed AnchorsJeremy McKeonspecial
09/01/2022FinalJeremy McKeonprogress
09/01/2022Mechanical SystemsJeremy McKeonspecial
09/01/2022Structural Steel - DetailsJeremy McKeonspecial
▾Documents — 49 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch3
08/28/2026B07997362-I1Request digital key ↗
08/23/2026B01123120-I1Request digital key ↗
08/15/2026B07997382-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Antenna1
09/02/2026B00364306-I1Request digital key ↗
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION4
11/01/2023320963999Open ↗
10/27/2023320963999Open ↗
01/04/2017320963999Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION3
01/03/2017320963999Open ↗
02/24/2015320963999Open ↗
06/26/2014320963999Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
08/29/2018320963999Open ↗
▸Seals & Professional Certifications15
▸DOB NOWSpecial Inspector Seal & Signature8
09/01/2026B07997382-I1Open ↗
09/01/2026B07997382-I1Open ↗
08/29/2026B07997362-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/02/2026B00364306-I1Open ↗
08/28/2026B07997382-I1Open ↗
08/28/2026B07997362-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
11/15/2018320963999Open ↗
05/22/2014320963999Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/29/2026B07997362-I1Open ↗
▸Trade Schedules & Equipment4
▸BISEQUIPMENT USE APPLICATION/PERMIT2
12/06/2023320963999Open ↗
11/10/2023320963999Open ↗
▸BISEQUIPMENT USE PERMITS2
12/06/2023320963999Open ↗
11/10/2023320963999Open ↗
▸Safety & Tenant Protection2
▸DOB NOWTenant Protection Plan1
08/13/2026B00364306-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026B01123120-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/02/2026B00364306-I1Open ↗
08/28/2026B07997362-I1Open ↗
08/15/2026B07997382-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/22/2014320963999Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
11/15/2018320963999Open ↗
05/22/2014320963999Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
11/10/2023320963999Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
11/10/2023320963999Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
11/10/2023320963999Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
11/10/2023320963999Open ↗
▸Approvals, Objections & Sign-offs3
▸BISADMINISTRATIVE OBJECTIONS1
05/22/2014320963999Open ↗
▸BISSUPERSEDING LETTER1
02/24/2015320963999Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/05/2023320963999Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
05/22/2014320963999Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
05/22/2014320963999Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/23/2026B01123120-I1Open ↗