← Back
Elevator apt, fireproof without stores
815 PELHAM PARKWAY NORTH
BRONX · BIN 2093365
💬 Discuss this project
1947Year Built
6Stories
D3Building Class
R5Zoning
424,625 sfGross Floor Area
451Units
LL97 Covered6 Open Violations 0 unresolved · 6 paperwork only ▸FISP: No Report FiledFDNY Report ↗
Elevator apt, fireproof without stores · Owner of record: NYC HOUSING AUTHORITY · 396,000 sf lot · 1.07 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralGeneral
Roof14p · 1 filing · 6 docs
Bulkhead3p · 1 filing · 6 docs
2 jobs · most recent 09/26/2018
General Wiring
FiledStatusContractorScope
09/26/2018Permit IssuedARCH ELECTRIC, INC.General Wiring
09/26/2018Permit IssuedARCH ELECTRIC, INC.General Wiring
Building Lifecycle
All (22)Filed (2)Violation (6)Objection (4)Special Inspection (10)
01/24/2025
Objection resolved — Addressed
01/23/2025
Special inspection requirement — Final
01/22/2025
Objection raised — Admin
01/17/2025
Objection resolved — Addressed
01/16/2025
Filed — Alteration
Rooftop replacement and rooftop renovation
X01142435-S2
01/09/2025
Objection raised — Admin
01/08/2025
Filed — Alteration
Rooftop replacement and rooftop renovation
X01142435-I1
01/08/2025
Special inspection requirement — Concrete - Cast-In-Place
01/06/2025
Special inspection requirement — Tenant Protection Plan Compliance
12/13/2024
Special inspection requirement — Air barrier - visual inspection
11/14/2024
Violation issued (FDNY_NOV, closed)
11/14/2024
Special inspection requirement — Energy Code Compliance Inspections
11/14/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/14/2024
Special inspection requirement — Insulation placement and R values
11/14/2024
Special inspection requirement — Masonry
11/14/2024
Special inspection requirement — Post-installed Anchors
11/14/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
01/03/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/03/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/13/2010
Violation issued (ECB, closed)
Elevators
08/08/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYCHA 99103/22/2026
NYCHA303/21/2026
NYC HOUSING AUTHORITY403/21/2026
NEW YORK CITY HOUSING AUTHORITY703/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CSA GROUP101/16/2025
SYNERGY STRATEGIC DESIGN ARCHITECTS101/08/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NERIS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ZITO, ROCCOElectrical103/21/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISPLISSUEDPERFECT PLUMBING & HEATING CORP.02/23/2006
BISOTISSUEDNAP CONSTRUCTION COMPANY INC.02/14/2006
BISEQISSUEDTWIN & SWING SCAFFOLDING05/04/2004
BISPLISSUEDOLYMPIA MECHANICAL02/26/2004
BISPLISSUEDV. C. VITANZA SONS INC07/30/1990
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
01/23/2025Final—progress
01/08/2025Concrete - Cast-In-Place—special
01/06/2025Tenant Protection Plan Compliance—special
12/13/2024Air barrier - visual inspection—energy_progress
11/14/2024Energy Code Compliance Inspections—progress
11/14/2024Fire-Resistant Penetrations and Joints—special
11/14/2024Insulation placement and R values—energy_progress
11/14/2024Masonry—special
11/14/2024Post-installed Anchors—special
11/14/2024Structural Stability – Alterations of existing buildings—special
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026X01142435-S2Request digital key ↗
08/20/2026X01142435-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
10/02/2018220670469Open ↗
10/02/2018220670469Open ↗
▸Seals & Professional Certifications4
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
10/02/2018220670469Open ↗
10/02/2018220670469Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026X01142435-S2Open ↗
08/20/2026X01142435-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
10/02/2018220670469Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
10/02/2018220670469Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
10/02/2018220670469Open ↗
10/02/2018220670469Open ↗
▸Approvals, Objections & Sign-offs3
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter2
08/13/2026X01142435-I1Open ↗
08/13/2026X01142435-S2Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
10/02/2018220670469Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
10/02/2018220670469Open ↗
10/02/2018220670469Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
10/02/2018220670469Open ↗
10/02/2018220670469Open ↗